← Back
Primarily 5-6 family with 1 store or office
372 CLINTON AVENUE
BROOKLYN · BIN 3055459
💬 Discuss this project
1878Year Built
5Stories
S5Building Class
R6BZoning
7,368 sfGross Floor Area
6Units
Rent Stabilized7 Open Violations ▸FDNY Report ↗
Primarily 5-6 family with 1 store or office · Owner of record: 372 CLINTON LLC · 2,750 sf lot · 2.68 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 4Under Construction24p · 2 filings · 20 docs
Floor 3Under Construction22p · 3 filings · 20 docs
Floor 2Under Construction19p · 2 filings · 20 docs
Floor 1Under Construction22p · 2 filings · 20 docs
CellarUnder Construction22p · 3 filings · 20 docs
BasementUnder Construction12p · 1 filing · 20 docs
Sub-BasementUnder Construction7p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
293 HENRY3007/08/2026
372 CLINTON LLC303/22/2026
BROOKLYN FREE SCHOOL203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/01/2022$3.2M—BROOKLYN FREE SCHOOL → 372 CLINTON LLC$429/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAMANN ENGINEERING, PLLC908/19/2026
JERRY MISIEWICZ104/07/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BIG ORANGE EXPEDITING1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROCK FACE CONSTR INCGeneral Contractor1104/09/2026
PREMIER FLOW PLBG AND HTGPlumbing207/08/2026
PREMIER FLOW PLBG AND HTGFire Protection107/08/2026
BIG ORANGE SAFETY FIRSTGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HAMANN ENGINEERING, PLLC4949602/06/2026
Building Lifecycle
All (80)Filed (10)Permit Issued (11)Signed Off (1)Violation (30)Inspection (5)Objection (8)Special Inspection (15)
08/19/2026
Filed — Alteration CO
INTERIOR RENOVATION TO SHOW CONVERSION OF CHILDREN SCHOOL TO 5 FAMILY HOUSE AS PER PLANS FILED HEREWITH. CHANGE TO CERTIFICATE OF OCCUPANCY REQUESTED.
B00937194-S3
08/05/2026
Objection raised — Other
08/05/2026
Objection raised — Admin
08/05/2026
Objection raised — Admin
08/05/2026
Objection raised — Admin
07/21/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/16/2026
Objection resolved — Addressed
06/15/2026
Permit issued — Plumbing
B00774059-I1-PL
04/20/2026
Objection raised — Scope
04/15/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/15/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/07/2026
Filed — Alteration CO
INTERIOR RENOVATION TO SHOW CONVERSION OF CHILDREN SCHOOL TO 5 FAMILY HOUSE AS PER PLANS FILED HEREWITH. CHANGE TO CERTIFICATE OF OCCUPANCY REQUESTED.
B00937194-S2
04/03/2026
Permit issued — General Construction
B00937194-I1-GC
04/03/2026
Special inspection requirement — Post-installed Anchors
04/03/2026
Special inspection requirement — Final
04/03/2026
Special inspection requirement — Structural Steel - Details
04/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
03/23/2026
Permit issued — General Construction
B00937194-I1-GC
03/21/2026
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
03/12/2026
Filed — Alteration
Plumbing work as per plans attached herewith. No change in use, egress and occupancy.
B00774059-P2
03/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/04/2026
Special inspection requirement — Concrete - Cast-In-Place
CARL HAMANN
03/04/2026
Special inspection requirement — Energy Code Compliance Inspections
CARL HAMANN
03/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CARL HAMANN
02/27/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/27/2026
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/17/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
02/06/2026
Filed — Alteration CO
INTERIOR RENOVATION TO SHOW CONVERSION OF CHILDREN SCHOOL TO 5 FAMILY HOUSE AS PER PLANS FILED HEREWITH. CHANGE TO CERTIFICATE OF OCCUPANCY REQUESTED.
B00937194-P3
12/02/2025
Signed off — Alteration
B00774056-I1
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/03/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/11/2025
Permit issued — General Construction
B00937194-I1-GC
03/28/2025
Permit issued — General Construction
B00774056-I1-GC-CX
03/14/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/10/2025
Filed — Alteration
Plumbing work as per plans attached herewith. No change in use, egress and occupancy.
B00774059-P1
03/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/21/2025
Permit issued — Sprinklers
B00937194-S1-EW-SP
01/23/2025
Objection resolved — Addressed
12/24/2024
Objection raised — Admin
12/20/2024
Filed — Alteration CO
INTERIOR RENOVATION TO SHOW CONVERSION OF CHILDREN SCHOOL TO 5 FAMILY HOUSE AS PER PLANS FILED HEREWITH. CHANGE TO CERTIFICATE OF OCCUPANCY REQUESTED.
B00937194-S1
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/2024
Filed — Alteration CO
INTERIOR RENOVATION TO SHOW CONVERSION OF CHILDREN SCHOOL TO 5 FAMILY HOUSE AS PER PLANS FILED HEREWITH. CHANGE TO CERTIFICATE OF OCCUPANCY REQUESTED.
B00937194-P1
09/13/2024
Special inspection requirement — Concrete - Cast-In-Place
CARL HAMANN
09/13/2024
Special inspection requirement — Energy Code Compliance Inspections
CARL HAMANN
09/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
CARL HAMANN
08/19/2024
Permit issued — Plumbing
B00774059-I1-PL
08/06/2024
Filed — Alteration
Plumbing work as per plans attached herewith. No change in use, egress and occupancy.
B00774059-I1
07/23/2024
Permit issued — General Construction
B00937194-I1-GC
07/22/2024
Permit issued — General Construction
B00774056-I1-GC-CX
11/13/2023
Filed — Alteration CO
INTERIOR RENOVATION TO SHOW CONVERSION OF CHILDREN SCHOOL TO 5 FAMILY HOUSE AS PER PLANS FILED HEREWITH. CHANGE TO CERTIFICATE OF OCCUPANCY REQUESTED.
B00937194-I1
10/11/2023
Permit issued — Mechanical Systems
B00774056-I1-GC-CX
10/11/2023
Special inspection requirement — Sprinkler Systems
CARL HAMANN
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/2023
Permit issued — Mechanical Systems
B00774056-I1-GC-CX
Latest 60 of 80 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedPREMIER FLOW PLBG AND HTG06/15/2026
DOB NOWGeneral ConstructionPermit IssuedROCK FACE CONSTR INC04/03/2026
DOB NOWGeneral ConstructionPermit IssuedROCK FACE CONSTR INC03/23/2026
DOB NOWGeneral ConstructionPermit IssuedROCK FACE CONSTR INC04/11/2025
DOB NOWGeneral ConstructionSigned-offROCK FACE CONSTR INC03/28/2025
DOB NOWSprinklersPermit IssuedGALICJA PLBG AND HTG CORP02/21/2025
DOB NOWPlumbingPermit IssuedGALICJA PLBG AND HTG.CORP08/19/2024
DOB NOWGeneral ConstructionPermit IssuedROCK FACE CONSTR INC07/23/2024
DOB NOWGeneral ConstructionSigned-offROCK FACE CONSTR INC07/22/2024
DOB NOWMechanical SystemsSigned-offROCK FACE CONSTR INC10/11/2023
DOB NOWMechanical SystemsSigned-offBIG ORANGE SAFETY FIRST05/04/2023
BIS—ISSUEDANTARTIC CONSTRUTION INC.09/02/2010
BISFPISSUEDFIRE FOE CORPORATION02/27/1996
BISFBISSUEDD. SERINI HEATING05/02/1994
1 project · most recent 08/19/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/19/2026Permit IssuedROCK FACE CONSTR INCHeating and Air Conditioning Systems
Heat / Cool
Daikin 4MXTH36AVJU9 36,000 BTU · Condensing Unit ×3
5MXTH40AVJU9 48,000 BTU · Condensing Unit ×2
1 project · most recent 03/12/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/12/2026Permit IssuedPREMIER FLOW PLBG AND HTGGas, Water/Sanitary
1 project · most recent 01/17/2023
General Wiring
FiledStatusContractorScope
01/17/2023Permit IssuedDENNISON ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/21/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/21/2026Certified Sprinkler - SP - RoughingCertifiedView ↗
02/17/2026Fail-Final CND-Occupancy InspectionFailView ↗
10/03/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
04/03/2026Post-installed Anchors—special
04/03/2026Final—progress
04/03/2026Structural Steel - Details—special
04/03/2026Structural Stability – Alterations of existing buildings—special
03/10/2026Fire-Resistant Penetrations and Joints—special
03/04/2026Concrete - Cast-In-PlaceCARL HAMANNspecial
03/04/2026Energy Code Compliance InspectionsCARL HAMANNprogress
03/04/2026Fire-Resistant Penetrations and JointsCARL HAMANNspecial
03/06/2025Fire-Resistant Penetrations and Joints—special
09/13/2024Concrete - Cast-In-PlaceCARL HAMANNspecial
09/13/2024Energy Code Compliance InspectionsCARL HAMANNprogress
09/13/2024Fire-Resistant Penetrations and JointsCARL HAMANNspecial
10/11/2023Sprinkler SystemsCARL HAMANNspecial
07/13/2022FinalCARL HAMANNprogress
07/13/2022Mechanical SystemsCARL HAMANNspecial
▾Documents — 97 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/27/2026B00774056-I1Request digital key ↗
08/24/2026B00774059-P2Request digital key ↗
08/24/2026B00774059-P1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits17
▸DOB NOWLPC Approval/Permit10
08/24/2026B00774059-I1Open ↗
08/24/2026B00774059-P1Open ↗
08/21/2026B00937194-S3Open ↗
Showing 3 of 10 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION5
09/14/2011320123834Open ↗
05/21/2010320123834Open ↗
02/01/2010320123834Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
11/26/2010320123834Open ↗
▸BISWORK PERMIT APPLICATION1
09/23/2010320123834Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/27/2026B00774056-I1Open ↗
08/24/2026B00774059-P1Open ↗
08/24/2026B00774059-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026B00937194-I1Open ↗
08/28/2026B00937194-S1Open ↗
08/26/2026B00774056-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B00937194-I1Open ↗
08/26/2026B00774056-I1Open ↗
08/24/2026B00937194-P4Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
02/01/2010320123834Open ↗
02/28/2008310089436Open ↗
09/05/2007310017530Open ↗
▸BISPC FULL REPORT1
09/05/2007310017530Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
04/25/2008310089436Open ↗
01/18/2008310081121Open ↗
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist4
08/21/2026B00937194-P4Open ↗
08/13/2026B00937194-I1Open ↗
08/13/2026B00937194-P1Open ↗
Showing 3 of 4 on file for this type
▸BISSTREET TREE CHECKLIST1
06/23/2010320123834Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00937194-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form6
08/27/2026B00774056-I1Open ↗
08/24/2026B00937194-S1Open ↗
08/24/2026B00937194-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
02/28/2008310089436Open ↗
09/05/2007310017530Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
06/23/2010320123834Open ↗
02/02/2010320123834Open ↗
▸Approvals, Objections & Sign-offs12
▸BISADMINISTRATIVE OBJECTIONS4
02/01/2010320123834Open ↗
02/07/2008310089436Open ↗
01/18/2008310081121Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
07/22/2010320123834Open ↗
02/01/2010320123834Open ↗
04/25/2008310089436Open ↗
Showing 3 of 4 on file for this type
▸BISLANDMARKS APPROVAL3
04/23/2012320123834Open ↗
02/18/2010320123834Open ↗
04/25/2008310089436Open ↗
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST1
04/23/2012320123834Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/31/2010320123834Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/01/2010320123834Open ↗
▸Other Documents13
▸DOB NOWProof of Historic Building8
08/24/2026B00774059-P1Open ↗
08/24/2026B00774059-I1Open ↗
08/21/2026B00937194-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProperty Ownership Certification4
08/24/2026B00937194-P3Open ↗
08/24/2026B00937194-P1Open ↗
08/24/2026B00937194-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPLOT DIAGRAM1
04/23/2012320123834Open ↗