← Back
Five to six families
384 12 STREET
BROOKLYN · BIN 3023272
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6BZoning
5,469 sfGross Floor Area
6Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Five to six families · Owner of record: 384 12TH STREET LLC · 2,250 sf lot · 2.43 FAR built · Flood zone X
Locations of Work
Architecture
Floor 36p · 2 filings · 20 docs
Floor 2
Floor 1
1 job · most recent 10/25/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/25/2023Signed-offDLM CONTRACTORS INCHeating and Air Conditioning Systems
Heat / Cool
Cooper & Hunter Model Number : CH-ES24-230VO 24,000 BTU · Condensing Unit ×2
Model Number : CH-M24AHU 24,000 BTU · Fan Coil Indoor ×2
2 jobs · most recent 08/10/2023
General Wiring
FiledStatusContractorScope
08/10/2023Permit IssuedCEL SVCS INC DBA CEL ELECGeneral Wiring
03/26/2018CompleteRIVIERA ELECTRIC CORPGeneral Wiring
Building Lifecycle
All (39)Filed (3)Permit Issued (3)Violation (11)Inspection (3)Objection (6)Special Inspection (13)
04/30/2026
Violation issued (HPD, closed)
A
12/19/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/06/2023
Violation issued (HPD, closed)
C
12/06/2023
Violation issued (HPD, open)
C
11/03/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/01/2023
Permit issued — Mechanical Systems
B08053236-S1-MS
10/31/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/26/2023
Permit issued — Plumbing
B08055499-I1-PL
10/25/2023
Filed — Alteration
Proposed filing for heating and cooling system, with condensers on the roof and heating unit / air handler in the apartments on the 3rd fl. This application is filed in conjunction with GC application. No change to use, egress or occupancy proposed
B08053236-S1
10/17/2023
Special inspection requirement — Tenant Protection Plan Compliance
Choudhry Yusaf
10/16/2023
Special inspection requirement — HVAC-R and service water heating system controls
Choudhry Yusaf
10/16/2023
Special inspection requirement — Mechanical Systems
Choudhry Yusaf
10/16/2023
Special inspection requirement — Final
Choudhry Yusaf
10/16/2023
Special inspection requirement — HVAC-R and service water heating equipment
Choudhry Yusaf
10/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Choudhry Yusaf
10/16/2023
Special inspection requirement — Maintenance information
Choudhry Yusaf
05/08/2023
Permit issued — General Construction
B08053236-I1-GC
02/14/2023
Filed — Alteration
B08055499-I1
01/12/2023
Objection raised — Admin
01/12/2023
Objection resolved — Addressed
01/12/2023
Objection raised — Other
01/12/2023
Objection resolved — Addressed
01/12/2023
Objection raised — Other
01/12/2023
Objection resolved — Addressed
01/10/2023
Filed — Alteration
Proposed filing for heating and cooling system, with condensers on the roof and heating unit / air handler in the apartments on the 3rd fl. This application is filed in conjunction with GC application. No change to use, egress or occupancy proposed
B08053236-I1
01/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Choudhry Yusaf
01/04/2023
Special inspection requirement — Lighting in dwelling units
Choudhry Yusaf
01/04/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Choudhry Yusaf
01/04/2023
Special inspection requirement — Insulation placement and R values
Choudhry Yusaf
12/12/2022
Special inspection requirement — Final
Choudhry Yusaf
12/12/2022
Special inspection requirement — Tenant Protection Plan Compliance
Choudhry Yusaf
11/09/2022
Violation issued (HPD, closed)
I
04/05/2021
Violation issued (HPD, closed)
A
11/15/2017
Violation issued (HPD, closed)
I
04/12/2017
Violation issued (ECB, closed)
Construction
11/01/2016
Violation issued (HPD, closed)
I
08/16/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/19/1989
Violation issued (HPD, open)
C
11/19/1989
Violation issued (HPD, open)
C
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
384 12TH ST2207/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/23/2015$3.6M—SLOPE SANDS LLC → 384 12TH STREET LLC$658/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CNA BUILDERS & CONSULTANT CORP310/25/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DLM CONTRACTORS INCGeneral Contractor403/21/2026
CEL SVCS INC DBA CEL ELECElectrical103/22/2026
GEORGE GRANDVILLEElectrical103/21/2026
GRANDVILLE GEORGEElectrical103/21/2026
STARLITE PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CNA BUILDERS AND CONSULTA2898310/25/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offDLM CONTRACTORS11/01/2023
DOB NOWPlumbingSigned-offSTARLITE PLBG & HTG CORP10/26/2023
DOB NOWGeneral ConstructionPermit IssuedDLM CONTRACTORS05/08/2023
BISOTISSUEDEMG INDUSTRIAL CHIMNEY IN03/01/2018
BISPLISSUEDALJER PLBG & HTG CORP10/06/2017
BISOTISSUEDAAA P INTERNATIONAL INC07/07/2017
BISPLISSUEDPLBG P & H INC05/26/2016
BISOTISSUEDMASTERPIECE CONSTRUCTION04/18/2016
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/19/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/31/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
10/17/2023Tenant Protection Plan ComplianceChoudhry Yusafspecial
10/16/2023HVAC-R and service water heating system controlsChoudhry Yusafenergy_progress
10/16/2023Mechanical SystemsChoudhry Yusafspecial
10/16/2023FinalChoudhry Yusafprogress
10/16/2023HVAC-R and service water heating equipmentChoudhry Yusafenergy_progress
10/16/2023HVAC-R and service water piping design and insulationChoudhry Yusafenergy_progress
10/16/2023Maintenance informationChoudhry Yusafenergy_progress
01/04/2023Fire-Resistant Penetrations and JointsChoudhry Yusafspecial
01/04/2023Lighting in dwelling unitsChoudhry Yusafenergy_progress
01/04/2023Fenestration and door U-factor and product ratingsChoudhry Yusafenergy_progress
01/04/2023Insulation placement and R valuesChoudhry Yusafenergy_progress
12/12/2022FinalChoudhry Yusafprogress
12/12/2022Tenant Protection Plan ComplianceChoudhry Yusafspecial
▾Documents — 79 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/28/2026B08053236-S1Request digital key ↗
08/27/2026B08055499-I1Request digital key ↗
08/14/2026B08053236-I1Request digital key ↗
▸Applications & Permits11
▸BISWORK PERMIT APPLICATION5
02/23/2018340586379Open ↗
10/10/2017321544968Open ↗
07/11/2017321544968Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION3
01/24/2018321544968Open ↗
06/02/2017321544968Open ↗
09/26/2016321315073Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION3
02/23/2018340586379Open ↗
03/27/2017321544968Open ↗
03/04/2016321315073Open ↗
▸Seals & Professional Certifications24
▸DOB NOWProgress Inspector Seal & Signature9
08/24/2026B08053236-S1Open ↗
08/24/2026B08053236-S1Open ↗
08/24/2026B08053236-S1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
07/13/2018321544968Open ↗
06/08/2018340586379Open ↗
04/11/2017321544968Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/24/2026B08053236-S1Open ↗
08/24/2026B08053236-S1Open ↗
08/22/2026B08053236-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/28/2026B08053236-I1Open ↗
08/28/2026B08053236-S1Open ↗
08/27/2026B08055499-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
02/23/2018340586379Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/23/2018340586379Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/23/2018340586379Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
03/27/2017321544968Open ↗
03/04/2016321315073Open ↗
▸BISBOILER APPROVAL : 900A1
07/06/2017321544968Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
09/26/2016321315073Open ↗
▸Safety & Tenant Protection4
▸BISTenant Protection Plan and Notes4
04/19/2017321544968Open ↗
03/27/2017321544968Open ↗
03/21/2016321315073Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos6
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
02/23/2018340586379Open ↗
03/27/2017321544968Open ↗
03/04/2016321315073Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/28/2026B08053236-S1Open ↗
08/27/2026B08055499-I1Open ↗
08/14/2026B08053236-I1Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
07/13/2018321544968Open ↗
06/08/2018340586379Open ↗
10/10/2017321544968Open ↗
Showing 3 of 5 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
07/13/2018321544968Open ↗
06/08/2018340586379Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
02/23/2018340586379Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/23/2018340586379Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
07/13/2018321544968Open ↗
06/08/2018340586379Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/04/2016321315073Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
07/13/2018321544968Open ↗
06/08/2018340586379Open ↗
02/23/2018340586379Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION4
03/14/2018321544968Open ↗
07/06/2017321544968Open ↗
09/29/2016321315073Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET2
03/27/2017321544968Open ↗
03/04/2016321315073Open ↗
▸BISBOROUGH INTAKE FORM2
07/13/2018321544968Open ↗
06/08/2018340586379Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/23/2018340586379Open ↗