← Back
Elevator apt, fireproof without stores
3991 SAXON AVENUE
BRONX · BIN 2129741
💬 Discuss this project
2024Year Built
6Stories
D3Building Class
R7-1Zoning
12,433 sfGross Floor Area
17Units
Rent Stabilized11 Open Violations ▸
Elevator apt, fireproof without stores · Owner of record: 3991 SAXSON LLC · 4,108 sf lot · 3.03 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof34p · 2 filings · 20 docs
Bulkhead1p · 1 filing · 2 docs
Floor 635p · 2 filings · 20 docs
Floor 533p · 2 filings · 20 docs
Floor 430p · 1 filing · 20 docs
Floor 331p · 2 filings · 20 docs
Floor 233p · 2 filings · 20 docs
Floor 135p · 1 filing · 20 docs
Cellar31p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
3991 SAXON AVE3007/08/2026
PARSONS CONSTRUCTION1003/22/2026
3991 SAXSON LLC103/22/2026
ROCK BUILDERS203/22/2026
3991 SAXON LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/14/2023$1.2M—— → —— not available
01/28/2020$722K—Private party → S&N SAXON LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AT-DESIGN609/03/2024
VASILIOS ARTEMIOU PE705/31/2024
AP PROFESSIONAL ENGINEERING PLLC201/16/2024
STRUCTURAL ENGINEERING TECHNOLOGIES311/13/2023
BADALY ARCHITECTS107/29/2022
MOHAMMAD AHEAD, PE101/03/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SPEEDY EXPEDITING2003/21/2026
BAC Developers Group603/21/2026
ARSENAL BUILDING CONSULTANTS LLC203/21/2026
SANDEEP KAUR203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROCK BUILDERS INCGeneral Contractor1107/08/2026
PARSONS CONSTRUCTION INCGeneral Contractor603/21/2026
B SOSA ENTERPRISES CORPGeneral Contractor303/21/2026
DYNAMIX SCAFFOLD GROUP LLGeneral Contractor203/21/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
POWER DIRECT ELECTRIC INCElectrical103/22/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
HIGH QUALITY ELECTRIC OFElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
REGIONAL TESTING CORP.3941109/03/2024
Building Lifecycle
All (176)Filed (20)Permit Issued (11)Signed Off (7)Violation (18)Inspection (10)Objection (80)Special Inspection (30)
09/02/2026
Violation issued (HPD, open)
B
09/02/2026
Violation issued (HPD, open)
A
09/02/2026
Violation issued (HPD, open)
B
09/02/2026
Violation issued (HPD, open)
B
09/02/2026
Violation issued (HPD, open)
B
09/02/2026
Violation issued (HPD, open)
B
09/02/2026
Violation issued (HPD, open)
B
09/02/2026
Violation issued (HPD, open)
A
09/02/2026
Violation issued (HPD, open)
A
09/02/2026
Violation issued (HPD, open)
C
06/06/2026
Violation issued (HPD, closed)
B
04/15/2026
Violation issued (HPD, open)
C
04/15/2026
Violation issued (HPD, closed)
B
04/29/2025
Violation issued (HPD, closed)
A
04/03/2025
Violation issued (HPD, closed)
A
04/03/2025
Violation issued (HPD, closed)
A
11/21/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/04/2024
Special inspection requirement — Protection of exposed foundation insulation
Paul Raymond
09/04/2024
Special inspection requirement — Air barrier - visual inspection
Paul Raymond
09/04/2024
Special inspection requirement — Exterior lighting power
Paul Raymond
09/04/2024
Special inspection requirement — Fenestration areas
Paul Raymond
09/04/2024
Special inspection requirement — Fire-Resistance Rated Construction
Paul Raymond
09/04/2024
Special inspection requirement — Footing and Foundation
Paul Raymond
09/04/2024
Special inspection requirement — Electrical motors and elevators
Paul Raymond
09/04/2024
Special inspection requirement — Interior lighting power
Paul Raymond
09/04/2024
Special inspection requirement — Insulation placement and R values
Paul Raymond
09/04/2024
Special inspection requirement — Fenestration air leakage
Paul Raymond
09/04/2024
Special inspection requirement — Maintenance information
Paul Raymond
09/04/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Paul Raymond
09/04/2024
Special inspection requirement — Final
Paul Raymond
09/04/2024
Special inspection requirement — Lighting in dwelling units
Paul Raymond
09/04/2024
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
09/04/2024
Special inspection requirement — Lighting controls
Paul Raymond
09/04/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
GEORGE CAMBOURAKIS
09/04/2024
Special inspection requirement — Subgrade Inspections
Paul Raymond
09/04/2024
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
09/04/2024
Special inspection requirement — Air barrier — testing
Paul Raymond
09/04/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Paul Raymond
09/04/2024
Special inspection requirement — Metering
Paul Raymond
09/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
09/03/2024
Filed — New Building
Proposed six (6) story residential building as per plans.
X00553144-A5
08/13/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/03/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/27/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/26/2024
Signed off — New Building
Proposed six (6) story residential building as per plans.
X00553144-S3
06/17/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
06/10/2024
Signed off — New Building
Proposed six (6) story residential building as per plans.
X00553144-S1
06/05/2024
Special inspection requirement — Maintenance information
Paul Raymond
06/05/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Paul Raymond
06/05/2024
Special inspection requirement — HVAC-R and service water heating system controls
Paul Raymond
06/05/2024
Special inspection requirement — HVAC-R and service water heating equipment
Paul Raymond
06/05/2024
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
06/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
06/05/2024
Special inspection requirement — Post-installed Anchors
Paul Raymond
05/31/2024
Filed — New Building
Proposed six (6) story residential building as per plans.
X00553144-A2
05/31/2024
Permit issued — Structural
X00553144-I1-GC-CX
05/31/2024
Objection raised — Structural
05/31/2024
Objection resolved — Addressed
05/28/2024
Objection resolved — Addressed
05/28/2024
Objection resolved — Addressed
Latest 60 of 176 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedROCK BUILDERS INC05/31/2024
DOB NOWSupported ScaffoldSigned-offPARSONS CONSTRUCTION INC01/22/2024
DOB NOWPlumbingSigned-offA M B MECHANICAL INC01/19/2024
DOB NOWSidewalk ShedSigned-offPARSONS CONSTRUCTION INC12/12/2023
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN11/13/2023
DOB NOWMechanical SystemsSigned-offROCK BUILDERS INC10/23/2023
DOB NOWSupport of ExcavationSigned-offROCK BUILDERS INC10/20/2023
DOB NOWFoundationPermit IssuedROCK BUILDERS INC09/07/2023
DOB NOWConstruction FenceSigned-offROCK BUILDERS INC06/21/2023
DOB NOWFoundationPermit IssuedB SOSA ENTERPRISES CORP06/07/2022
DOB NOWSidewalk ShedSigned-offDYNAMIX SCAFFOLD GROUP LL01/03/2022
1 project · most recent 09/03/2024
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/03/2024Permit IssuedROCK BUILDERS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin 3MXS24NMVJU 24,000 BTU · Heat Pump Outdoor ×8
RMXS48LVJU 48,000 BTU · Heat Pump Outdoor ×5
2MXS18NMVJU 18,000 BTU · Heat Pump Outdoor ×4
Amana PTH073G25 7,600 BTU · Ptac ×23
PTH123G25 12,000 BTU · Ptac ×11
PBH093G35CC 8,600 BTU · Ptac ×6
PTH073G35CC 7,200 BTU · Ptac ×6
Heating
Daikin 3MXS24NMVJU 24,000 BTU · Heat Pump Outdoor ×8
RMXS48LVJU 54,000 BTU · Heat Pump Outdoor ×5
2MXS18NMVJU 18,900 BTU · Heat Pump Outdoor ×4
Amana PTH073G25 6,800 BTU · Ptac ×23
PTH123G25 11,300 BTU · Ptac ×11
PBH093G35CC 8,600 BTU · Ptac ×6
PTH073G35CC 6,600 BTU · Ptac ×6
Ventilation
Nutone AEN110 50 CFM · Exhaust Fan ×34
QTXEN150 100 CFM · Exhaust Fan ×17
Greenheck CUE-099-VG 90 CFM · Exhaust Fan ×1
Panasonic WHISPERFRESH 90 CFM · Exhaust Fan ×17
1 project · most recent 09/03/2024
Sprinkler System
FiledStatusContractorScope
09/03/2024Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 09/03/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/03/2024Signed-offA M B MECHANICAL INCGas, Storm, Water/Sanitary
6 projects · most recent 05/08/2024
General Wiring
FiledStatusContractorScope
05/08/2024CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
05/01/2024CompletePOWER DIRECT ELECTRIC INC—
02/21/2024CompleteSTAR ELEC'L CONTRACTORS C—
02/01/2024CancelledPOWER DIRECT ELECTRIC INC—
12/14/2023CompleteHIGH QUALITY ELECTRIC OF—
01/10/2022CompleteHIGH QUALITY ELECTRIC OF—
1 project · most recent 09/03/2024
Concrete
FiledStatusContractorScope
09/03/2024Permit IssuedROCK BUILDERS INCConcrete
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
11/21/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/13/2024Pass-Final CND-Occupancy InspectionPassView ↗
07/03/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/27/2024Pass-Final CND-Occupancy InspectionPassView ↗
06/17/2024Fail-Final CND-Occupancy InspectionFailView ↗
05/14/2024Fail-Final CND-Occupancy InspectionFailView ↗
04/19/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/17/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/16/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
11/20/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 119
DateRequirementInspectorRole
09/04/2024MeteringPaul Raymondenergy_progress
09/04/2024Protection of exposed foundation insulationPaul Raymondenergy_progress
09/04/2024Fenestration areasPaul Raymondenergy_progress
09/04/2024Fenestration air leakagePaul Raymondenergy_progress
09/04/2024Maintenance informationPaul Raymondenergy_progress
09/04/2024Fenestration and door U-factor and product ratingsPaul Raymondenergy_progress
09/04/2024Lighting in dwelling unitsPaul Raymondenergy_progress
09/04/2024Air barrier - visual inspectionPaul Raymondenergy_progress
09/04/2024Subgrade InspectionsPaul Raymondspecial
09/04/2024Exterior Insulation and Finish Systems (EIFS)Paul Raymondspecial
09/04/2024Concrete - Cast-In-PlacePaul Raymondspecial
09/04/2024Subsurface Investigations (Borings/Test Pits)GEORGE CAMBOURAKISspecial
09/04/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
09/04/2024FinalPaul Raymondprogress
09/04/2024Fire-Resistance Rated ConstructionPaul Raymondprogress
09/04/2024Footing and FoundationPaul Raymondprogress
09/04/2024Energy Code Compliance InspectionsPaul Raymondprogress
09/04/2024Air barrier — testing Paul Raymondenergy_progress
09/04/2024Lighting controlsPaul Raymondenergy_progress
09/04/2024Electrical motors and elevatorsPaul Raymondenergy_progress
09/04/2024Interior lighting powerPaul Raymondenergy_progress
09/04/2024Exterior lighting powerPaul Raymondenergy_progress
09/04/2024Insulation placement and R valuesPaul Raymondenergy_progress
06/05/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
06/05/2024Energy Code Compliance InspectionsPaul Raymondprogress
Latest 25 of 119.
▾Documents — 145 on file (BIS + DOB NOW)
▸Plans & Drawings20
▸DOB NOWPlans/Sketch20
08/25/2026X00600704-I1Request digital key ↗
08/24/2026X00655846-I1Request digital key ↗
08/24/2026X00706797-I1Request digital key ↗
Showing 3 of 20 on file for this type
▸Zoning, Tax Lot & Property Records11
▸DOB NOWZoning Exhibit form (1-5)5
08/15/2026X00553144-I1Open ↗
08/14/2026X00553144-P1Open ↗
08/14/2026X00553144-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram5
08/15/2026X00553144-I1Open ↗
08/14/2026X00553144-P1Open ↗
08/14/2026X00553144-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026X00553144-I1Open ↗
▸Seals & Professional Certifications76
▸DOB NOWProgress Inspector Seal & Signature36
08/30/2026X00553144-I1Open ↗
08/30/2026X00553144-I1Open ↗
08/30/2026X00553144-I1Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature20
08/25/2026X00600704-I1Open ↗
08/24/2026X00655846-I1Open ↗
08/23/2026X00553144-S1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature20
09/02/2026X00553144-P5Open ↗
09/02/2026X00553144-P5Open ↗
09/02/2026X00553144-P5Open ↗
Showing 3 of 20 on file for this type
▸Trade Schedules & Equipment5
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
08/15/2026X00553144-I1Open ↗
08/14/2026X00553144-P1Open ↗
08/14/2026X00553144-P4Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection8
▸DOB NOWStreet Tree Checklist5
08/23/2026X00553144-A5Open ↗
08/15/2026X00553144-I1Open ↗
08/15/2026X00553144-A1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026X00553144-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/15/2026X00553144-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/15/2026X00553144-I1Open ↗
▸Energy Compliance4
▸DOB NOWEN2: As Built Energy Analysis.2
08/15/2026X00553144-I1Open ↗
08/13/2026X00553144-S1Open ↗
▸DOB NOWPreliminary Commissioning Report Certification2
08/15/2026X00553144-I1Open ↗
08/13/2026X00553144-S3Open ↗
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT5
08/15/2026X00553144-I1Open ↗
08/14/2026X00553144-P1Open ↗
08/14/2026X00553144-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/15/2026X00553144-I1Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertificate of Insurance1
08/15/2026X00553144-I1Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/15/2026X00553144-I1Open ↗
▸Other Documents13
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/15/2026X00553144-I1Open ↗
08/14/2026X00553144-P1Open ↗
08/14/2026X00553144-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial5
08/15/2026X00553144-I1Open ↗
08/14/2026X00553144-P1Open ↗
08/14/2026X00553144-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWFinal Survey1
08/15/2026X00553144-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00553144-S2Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/15/2026X00553144-I1Open ↗