← Back
BuildNYC
Three families
404 WEST 147TH STREET
MANHATTAN · BIN 1061428
💬 Discuss this project
1900Year Built
3Stories
C0Building Class
R6AZoning
4,424 sfGross Floor Area
3Units
Rent Stabilized0 Active Violations
Three families · 1,799 sf lot · 2.46 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentLandscapeGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofApartment alterationUnder Construction21p · 1 filing · 20 docs
Floor 3Unit PH4Under Construction14p · 2 filings · 20 docs
Floor 2Apartment alterationUnder Construction15p · 2 filings · 20 docs
Floor 1Heavy duty sidewalk shed installation4p · 1 filing · 2 docs
BasementApartment alterationUnder Construction1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Slade Gen. Contracting103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/03/2016$2.1M—Private party → Private party$486/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Vail Associates Architects408/05/2026
Mohammad Ahead, PE107/05/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Expediting103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
P.T. Construction GroupGeneral Contractor310/09/2026
Premier Flow Plumbing and HeatingPlumbing203/22/2026
Aramco ContractingScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Vail Associates Architect4315206/23/2026
Building Lifecycle
All (115)Filed (5)Permit Issued (4)Signed Off (1)Violation (41)Objection (52)Special Inspection (12)
10/07/2026
Permit issued — Structural
M01371492-S2-ST
09/15/2026
Permit issued — Mechanical Systems
M01371492-I1-GC-CX
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
08/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/18/2026
Permit issued — General Construction
M01441085-I1-GC
08/17/2026
Objection resolved — Resolved
08/17/2026
Objection resolved — Resolved
08/12/2026
Objection raised — Scope
08/12/2026
Objection raised — Inspections
08/12/2026
Objection raised — Admin
08/12/2026
Objection raised — Fire_Protection
08/05/2026
Filed — Alteration
ALT TYPE 2. FILED FOR REMOVAL OF INTERIOR PARTITIONS ONLY. NO STRUCTURAL WORK. NO CHANGE IN USE, EGRESS, OR OCCUPANCY. (SEE JOB #M01371492)
M01441085-I1
08/04/2026
Special inspection requirement — Final
Thomas Vail
07/24/2026
Objection resolved — Resolved
07/24/2026
Objection resolved — Addressed
07/24/2026
Objection resolved — Addressed
07/24/2026
Objection resolved — Addressed
07/24/2026
Objection resolved — Resolved
07/24/2026
Objection resolved — Addressed
07/24/2026
Objection resolved — Resolved
07/24/2026
Objection resolved — Resolved
07/24/2026
Objection resolved — Addressed
07/15/2026
Objection raised — Scope
07/15/2026
Objection raised — Inspections
07/15/2026
Objection raised — Admin
07/15/2026
Objection raised — Admin
07/15/2026
Objection raised — Admin
07/14/2026
Objection raised — Admin
07/14/2026
Objection raised — Cost
07/14/2026
Objection raised — Scope
07/14/2026
Objection raised — Energy
06/23/2026
Filed — Alteration
ALT TYPE 2. ALTERATION TO 2ND FLOOR & 3RD FLOOR APARTMENTS FOR NEW KITCHEN & BATHROOMS. NO CHANGE IN USE, EGRESS AND OCCUPANCY. NEW HEAT PUMP SYSTEM. NEW ELECTRICAL WIRING AND SERVICE PANELS. NEW FINISHES.
M01371492-S2
06/23/2026
Filed — Alteration
ALT TYPE 2. ALTERATION TO 2ND FLOOR & 3RD FLOOR APARTMENTS FOR NEW KITCHEN & BATHROOMS. NO CHANGE IN USE, EGRESS AND OCCUPANCY. NEW HEAT PUMP SYSTEM. NEW ELECTRICAL WIRING AND SERVICE PANELS. NEW FINISHES.
M01371492-S1
06/23/2026
Objection resolved — Addressed
06/23/2026
Objection resolved — Addressed
06/23/2026
Objection resolved — Addressed
06/23/2026
Objection resolved — Addressed
06/23/2026
Objection resolved — Addressed
06/23/2026
Objection resolved — Addressed
06/23/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Thomas Vail
06/23/2026
Special inspection requirement — Exterior lighting power
Thomas Vail
06/23/2026
Special inspection requirement — Fenestration air leakage
Thomas Vail
06/23/2026
Special inspection requirement — Lighting controls
Thomas Vail
06/21/2026
Special inspection requirement — HVAC-R and service water heating equipment
Thomas Vail
06/19/2026
Special inspection requirement — Final
Thomas Vail
06/16/2026
Objection resolved — Addressed
06/16/2026
Objection resolved — Addressed
06/16/2026
Objection resolved — Addressed
06/16/2026
Objection resolved — Addressed
06/16/2026
Objection resolved — Addressed
06/16/2026
Objection resolved — Addressed
06/16/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Thomas Vail
06/15/2026
Objection resolved — Addressed
06/09/2026
Objection raised — Structural
06/09/2026
Objection raised — Scope
06/09/2026
Objection raised — Energy
06/09/2026
Objection raised — Inspections
06/09/2026
Objection raised — Scope
06/09/2026
Objection raised — Admin
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedP.T. Construction Group10/07/2026
DOB NOWMechanical SystemsPermit IssuedP.T. Construction Group09/15/2026
DOB NOWGeneral ConstructionPermit IssuedP.T. Construction Group08/18/2026
DOB NOWSidewalk ShedSigned-offAramco Contracting07/05/2022
BISPLISSUEDPremier Flow Plumbing and Heating07/11/2017
BISOTISSUEDCalandra Enterprises07/06/2017
BISOTISSUEDNortheast Environ05/18/2005
BISFSISSUEDNeal M. Rudikoff05/17/2005
BISOTISSUEDSlade Contracting Compancy02/22/1994
1 project · most recent 06/23/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/23/2026Permit IssuedP.T. Construction GroupAir Conditioning Systems
Cooling
Mitsubishi Electric MLZ-KXO6NL 600 CFM · Vrf Indoor ×8
20,000 BTU/H HEAT PUMP OUTDOOR UNIT 4 tons · Heat Pump Outdoor ×4
2 projects · most recent 08/05/2026
General Wiring
FiledStatusContractorScope
08/05/2026Permit IssuedKraft ElectricGeneral Wiring
07/02/2022Permit IssuedRichard Neu—
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
08/19/2026Fire-Resistant Penetrations and Joints—special
08/04/2026FinalThomas Vailprogress
06/23/2026Structural Stability – Alterations of existing buildingsThomas Vailspecial
06/23/2026Exterior lighting powerThomas Vailenergy_progress
06/23/2026Fenestration air leakageThomas Vailenergy_progress
06/23/2026Lighting controlsThomas Vailenergy_progress
06/21/2026HVAC-R and service water heating equipmentThomas Vailenergy_progress
06/19/2026FinalThomas Vailprogress
06/16/2026Structural Stability – Alterations of existing buildingsThomas Vailspecial
05/15/2026Lighting in dwelling unitsThomas Vailenergy_progress
03/12/2026FinalThomas Vailprogress
03/12/2026Mechanical SystemsThomas Vailspecial
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
09/02/2026M00767274-I1Request digital key ↗
08/17/2026M01371492-S2Request digital key ↗
08/16/2026M01441085-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits9
▸DOB NOWLPC Approval/Permit4
08/17/2026M01371492-S2Open ↗
08/16/2026M01441085-I1Open ↗
08/15/2026M01371492-S1Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
03/06/2017122966816Open ↗
02/23/2017122966816Open ↗
01/25/2017122966816Open ↗
▸BISWORK PERMIT APPLICATION2
07/25/2017122966816Open ↗
07/18/2017122966816Open ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026M01371492-S1Open ↗
08/28/2026M01371492-I1Open ↗
08/28/2026M01371492-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/02/2026M00767274-I1Open ↗
08/17/2026M01371492-S1Open ↗
08/17/2026M01371492-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
06/26/2017122966816Open ↗
06/26/2017122966816Open ↗
01/25/2017122966816Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026M01371492-I1Open ↗
08/28/2026M01371492-I1Open ↗
08/24/2026M01371492-S2Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
01/25/2017122966816Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
01/25/2017122966816Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/28/2026M01441085-I1Open ↗
08/17/2026M01371492-S2Open ↗
08/16/2026M01441085-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
01/25/2017122966816Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/26/2017122966816Open ↗
01/25/2017122966816Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLANDMARKS APPROVAL2
03/02/2017122966816Open ↗
01/25/2017122966816Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/02/2017122966816Open ↗
01/25/2017122966816Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
01/25/2017122966816Open ↗
▸BISADDITIONAL INFORMATION1
07/27/2017122966816Open ↗