DOB10/02/2025Sws rendered non-compliant due to vehicle impact. Noted: sws has been dislodged with 6 double upright columns bent and displaced leaving approximately 50 linear feet of sws in danger of falling along 1ST avenue frontage.
DOB06/04/2025Failure to maintain exterior facade condition in a code compliant manner. As per time of inspection observed numerous step cracks throughout all exposures,broken blass windows at exposures one through four.also damaged, deteriorated mortar joints & lintels,spalling brick at all exposures. Remedy: repair and/or replace
ECB07/16/2018Failure to submit acceptable 8TH found report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #813007. Rmdy: submit required technical report.$6K due
ECB01/07/2025At time of inspection in response to complaint i observed underside of sidewalk shed a not illuminated as per 3307.6.4.8. This creates a hazardous condition for public walking underneath while dark and not beinNothing owed — awaiting certificate of correction
ECB11/14/2023At time of inspection observed power house building facade in state of disrepair. Cracks at multiple locations at all exposure. Smoke stack partially collapse on roof. Front concrete/metal awning sagging and inNothing owed — awaiting certificate of correction
ECB12/02/2022Failure to submit acceptable required CYCLE7A,8A,9A report of criticalexam documenting condition of exterior wall&appurtenances required by 28-302.4 for CONTROL913009.submit acceptable required technical reportNothing owed — awaiting certificate of correction
ECB12/02/2022Failure to submit acceptable required CYCLE7A,8A,9A report of criticalexam documenting condition of exterior wall&appurtenances required by 28-302.4 for CONTROL913010.submit acceptable required technical reportNothing owed — awaiting certificate of correction
ECB12/02/2022Failure to submit acceptable required CYCLE7A,8A,9A report of criticalexam documenting condition of exterior wall&appurtenances required by 28-302.4 for CONTROL913011.submit acceptable required technical reportNothing owed — awaiting certificate of correction
ECB12/02/2022Failure to submit acceptable required CYCLE7A,8A,9A report of criticalexam documenting condition of exterior wall&appurtenances required by 28-302.4 for CONTROL913008.submit acceptable required technical reportNothing owed — awaiting certificate of correction
ECB12/02/2022Failure to submit acceptable required CYCLE7A,8A,9A report of criticalexam documenting condition of exterior wall&appurtenances required by 28-302.4 for CONTROL913007.submit acceptable required technical reportNothing owed — awaiting certificate of correction
ECB11/15/2022Elevator currently out of serviceNothing owed — awaiting certificate of correction
ECB09/30/2022Electrical work without a permit outside on the roof ledge installation of 7 outdoor illuminated fixtures.rem:obtain permit.Nothing owed — awaiting certificate of correction
ECB03/07/2022No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix K3 of the 2014 nycbc. This is a controller feature which ensures passenger safety. Remedy; file application, install dlm aNothing owed — awaiting certificate of correction
ECB07/16/2018Failure to submit acceptable 8TH found report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #813011. Rmdy: submit required technical report.Nothing owed — awaiting certificate of correction
ECB07/12/2018Failure to maintain bldg walls and appurtenances noted at time of in spection defective copings were observed at exposure 1(east elevation)at south sections. Rmdy: maintain building exteriors.repair defects.Nothing owed — awaiting certificate of correction
ECB07/12/2018Failure to maintain building walls and appurtenances. Noted at time ofinspection (i) at EXP1 defective east elevations)spalled masonry abovemain entrances gates between flrs and 2; (ii)broken glass panes observNothing owed — awaiting certificate of correction
ECB07/12/2018Failure to maintain building walls and appurtenances. Noted at time ofinspection at EXP4 (north elevations) deteriorated metal cornice at underside of east end. Rmdy: maintain building exteriors; repair defectsNothing owed — awaiting certificate of correction
ECB07/12/2018Failure to maintain building walls and appurtenances. Noted at time ofinspection (i) at EXP1 defective eaves at various location; (ii) at pitched roof-deteriorated and dislodged sidings observed. Rmdy:maintaiNothing owed — awaiting certificate of correction
ECB05/18/2018Failure to submit acceptable 8TH round report of critical examination documenting condition of exterior walls and appurtenaces required by 28-302.4 for control #813009Nothing owed — awaiting certificate of correction
ECB05/16/201397#05 failure to maintain elevator device.respondent failed to allow mandatory annual inspection by the dept or approved agency per 28-304.6.1 and appendix k of the building code. Multiple attempts to gain acceNothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB06/30/2023Violation issued-failure to file 2020 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered3 identical filings
DOB06/30/2023Violation issued-failure to file 2021 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered3 identical filings
DOB06/20/2023Violation issued-failure to file 2018 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered3 identical filings
DOB06/20/2023Violation issued-failure to file 2019 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered3 identical filings
DOB04/25/2023Violation issued-failure to file 2022 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered3 identical filings
DOB09/06/2019Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tstThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2026). This one is not shown as answered3 identical filings
DOB04/05/2019Violation issued to elevator - failure to file category 1 2017 inspection/testThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2026). This one is not shown as answered
DOB04/06/2018Violation issued for failure to file annual boiler 2016 inspection reportThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered2 identical filings
DOB01/26/2018Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tstThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2026). This one is not shown as answered2 identical filings
DOB09/15/2017Violation issued to elevator-failure to file category 1 2016 inspection/testThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2026). This one is not shown as answered2 identical filings
DOB01/03/2017Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tstThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2026). This one is not shown as answered5 identical filings
DOB11/14/2016Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tstThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2026). This one is not shown as answered2 identical filings
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB02/22/2022Failed to file FISP cycle 9A technical report by 02/21/2022Issued 2022; DOB's record still lists it as active
DOB12/31/2020Elevator: elevatorrequired (DOB violation)Issued 2020; DOB's record still lists it as active3 identical filings
DOB12/27/2019Elevator: elevatorrequired (DOB violation)Issued 2019; DOB's record still lists it as active3 identical filings
DOB12/18/2018Elevator: elevatorrequired (DOB violation)Issued 2018; DOB's record still lists it as active3 identical filings
DOB05/31/2018Failed to file FISP cycle 8A technical report by 02/21/2017Issued 2018; DOB's record still lists it as active
DOB12/13/2017Elevator: elevatorrequired (DOB violation)Issued 2017; DOB's record still lists it as active3 identical filings
DOB11/28/2016Elevator: elevatorrequired (DOB violation)Issued 2016; DOB's record still lists it as active3 identical filings
Pier, dock, bulkhead · Owner of record: NYC Department of Small Business Services · 724,000 sf lot · 0.94 FAR built · Flood zone X500