← Back
City residence, one family
414 5 STREET
BROOKLYN · BIN 3021477
💬 Discuss this project
1901Year Built
2Stories
A4Building Class
R6BZoning
2,210 sfGross Floor Area
1Units
City residence, one family · 1,667 sf lot · 1.33 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingOther
Roof10p · 4 filings · 20 docs
Floor 22p · 1 filing · 19 docs
Floor 13p · 1 filing · 20 docs
Basement9p · 4 filings · 20 docs
Sub-Basement5p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/17/2019$2.3M—— → —$1,050/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GCF CONSULTING ENGINEERS510/28/2022
OLD STRUCTURES ENGINEERING205/11/2022
MOORHEAD & MOORHEAD205/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ORBIT PLBG & HTG INCPlumbing1007/08/2026
ABR CONSTRUCTION GROUP LLGeneral Contractor907/08/2026
PETER MILEVSKIElectrical103/21/2026
ORBIT PLBG HTGGeneral Contractor103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHEN ENGINEERING SERVICES1826205/11/2022
GFC CONSULTING ENGINEER P4127205/10/2022
Building Lifecycle
All (74)Filed (9)Permit Issued (6)Signed Off (4)Inspection (3)Objection (22)Special Inspection (30)
01/09/2023
Signed off — Alteration
Minor structural works as per plans submitted.
B00581454-I1
01/03/2023
Signed off — Alteration
Herewith filing for the installation of a mechanical system, as per plans submitted.
B00581442-I1
01/03/2023
Signed off — Alteration
Removal, replacement and installation of plumbing fixtures, as per plans submitted.
B00581405-I1
01/03/2023
Signed off — Alteration
Herewith filing interior alterations to an existing single family home. Work to include interior non structural demolition and installation of partitions, floors and millwork, as per plans submitted. No change to use, egress or occupancy.
B00511232-I1
11/23/2022
Permit issued — Structural
B00581454-I1-ST
11/23/2022
Permit issued — Mechanical Systems
B00581442-I1-MS
10/28/2022
Filed — Alteration
Removal, replacement and installation of plumbing fixtures, as per plans submitted.
B00581405-P2
06/21/2022
Permit issued — General Construction
B00511232-I1-GC
05/25/2022
Special inspection requirement — Mechanical Systems
Giap Flores
05/25/2022
Special inspection requirement — HVAC-R and service water heating system controls
Giap Flores
05/25/2022
Special inspection requirement — HVAC-R and service water heating equipment
Giap Flores
05/25/2022
Special inspection requirement — Duct leakage testing, insulation and design
Giap Flores
05/25/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Giap Flores
05/25/2022
Special inspection requirement — Energy Code Compliance Inspections
Giap Flores
05/25/2022
Special inspection requirement — Final
Giap Flores
05/25/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Giap Flores
05/23/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/23/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/22/2022
Objection resolved — Addressed
05/19/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/17/2022
Special inspection requirement — Fenestration air leakage
Granger Moorhead
05/17/2022
Special inspection requirement — Final
Granger Moorhead
05/17/2022
Special inspection requirement — Energy Code Compliance Inspections
Granger Moorhead
05/17/2022
Special inspection requirement — Lighting in dwelling units
Granger Moorhead
05/17/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Granger Moorhead
05/17/2022
Special inspection requirement — Lighting controls
Granger Moorhead
05/16/2022
Objection raised — Scope
05/16/2022
Special inspection requirement — Post-installed Anchors
HENLIA CHEN
05/16/2022
Special inspection requirement — Structural Steel - Welding
HENLIA CHEN
05/16/2022
Special inspection requirement — Final
HENLIA CHEN
05/16/2022
Special inspection requirement — Masonry
HENLIA CHEN
05/16/2022
Special inspection requirement — Structural Cold-Formed Steel
HENLIA CHEN
05/16/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
HENLIA CHEN
05/16/2022
Special inspection requirement — Structural Steel - Details
HENLIA CHEN
05/13/2022
Objection resolved — Addressed
05/13/2022
Objection resolved — Addressed
05/12/2022
Objection raised — Scope
05/12/2022
Objection raised — Scope
05/11/2022
Filed — Alteration
Minor structural works as per plans submitted.
B00581454-P1
05/10/2022
Filed — Alteration
Removal, replacement and installation of plumbing fixtures, as per plans submitted.
B00581405-P1
05/10/2022
Filed — Alteration
Herewith filing for the installation of a mechanical system, as per plans submitted.
B00581442-P1
05/10/2022
Filed — Alteration
Herewith filing interior alterations to an existing single family home. Work to include interior non structural demolition and installation of partitions, floors and millwork, as per plans submitted. No change to use, egress or occupancy.
B00511232-P1
05/02/2022
Permit issued — General Construction
B00511232-I1-GC
05/02/2022
Special inspection requirement — Fenestration air leakage
Granger Moorhead
05/02/2022
Special inspection requirement — Post-installed Anchors
HENLIA CHEN
05/02/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
HENLIA CHEN
05/02/2022
Special inspection requirement — Structural Steel - Details
HENLIA CHEN
05/02/2022
Special inspection requirement — Structural Steel - Welding
HENLIA CHEN
05/02/2022
Special inspection requirement — Structural Cold-Formed Steel
HENLIA CHEN
05/02/2022
Special inspection requirement — Final
HENLIA CHEN
05/02/2022
Special inspection requirement — Energy Code Compliance Inspections
Granger Moorhead
05/02/2022
Special inspection requirement — Final
Granger Moorhead
01/26/2022
Permit issued — Plumbing
B00581405-I1-PL
12/09/2021
Permit issued — General Construction
B00511232-I1-GC
10/21/2021
Objection resolved — Addressed
10/18/2021
Objection resolved — Addressed
10/18/2021
Objection resolved — Addressed
10/18/2021
Objection resolved — Addressed
10/18/2021
Objection resolved — Addressed
10/08/2021
Objection raised — Other
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedABR CONSTRUCTION GROUP LL11/23/2022
DOB NOWMechanical SystemsSigned-offABR CONSTRUCTION GROUP LL11/23/2022
DOB NOWGeneral ConstructionSigned-offABR CONSTRUCTION GROUP LL06/21/2022
DOB NOWGeneral ConstructionSigned-offABR CONSTRUCTION GROUP LL05/02/2022
DOB NOWPlumbingSigned-offORBIT PLBG & HTG INC01/26/2022
DOB NOWGeneral ConstructionSigned-offABR CONSTRUCTION GROUP LL12/09/2021
1 project · most recent 02/11/2022
General Wiring
FiledStatusContractorScope
02/11/2022CompleteELMAC ELECTRIC INC.General Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/23/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/23/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/19/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
05/25/2022Mechanical SystemsGiap Floresspecial
05/25/2022HVAC-R and service water heating system controlsGiap Floresenergy_progress
05/25/2022HVAC-R and service water heating equipmentGiap Floresenergy_progress
05/25/2022Duct leakage testing, insulation and designGiap Floresenergy_progress
05/25/2022HVAC-R and service water piping design and insulationGiap Floresenergy_progress
05/25/2022Energy Code Compliance InspectionsGiap Floresprogress
05/25/2022FinalGiap Floresprogress
05/25/2022Fire-Resistant Penetrations and JointsGiap Floresspecial
05/17/2022Fenestration air leakageGranger Moorheadenergy_progress
05/17/2022FinalGranger Moorheadprogress
05/17/2022Energy Code Compliance InspectionsGranger Moorheadprogress
05/17/2022Lighting in dwelling unitsGranger Moorheadenergy_progress
05/17/2022Fenestration and door U-factor and product ratingsGranger Moorheadenergy_progress
05/17/2022Lighting controlsGranger Moorheadenergy_progress
05/16/2022Post-installed AnchorsHENLIA CHENspecial
05/16/2022Structural Steel - WeldingHENLIA CHENspecial
05/16/2022FinalHENLIA CHENprogress
05/16/2022MasonryHENLIA CHENspecial
05/16/2022Structural Cold-Formed SteelHENLIA CHENspecial
05/16/2022Structural Stability – Alterations of existing buildingsHENLIA CHENspecial
05/16/2022Structural Steel - DetailsHENLIA CHENspecial
05/02/2022Fenestration air leakageGranger Moorheadenergy_progress
05/02/2022Post-installed AnchorsHENLIA CHENspecial
05/02/2022Structural Stability – Alterations of existing buildingsHENLIA CHENspecial
05/02/2022Structural Steel - DetailsHENLIA CHENspecial
Latest 25 of 34.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/01/2026B00581442-I1Request digital key ↗
09/01/2026B00581405-P1Request digital key ↗
09/01/2026B00581405-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Seals & Professional Certifications43
▸DOB NOWProgress Inspector Seal & Signature20
09/01/2026B00511232-P1Open ↗
09/01/2026B00511232-P1Open ↗
09/01/2026B00511232-P1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
08/25/2026B00581454-P1Open ↗
08/25/2026B00581454-P1Open ↗
08/25/2026B00581454-P1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/01/2026B00581442-I1Open ↗
09/01/2026B00581442-P1Open ↗
09/01/2026B00581405-P2Open ↗
Showing 3 of 9 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/01/2026B00581442-I1Open ↗
09/01/2026B00581405-I1Open ↗
09/01/2026B00581405-P1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00581442-I1Open ↗
08/13/2026B00511232-I1Open ↗