← Back
Primarily 2 family with 1 store or office
417 TOMPKINS AVENUE
BROOKLYN · BIN 3322569
💬 Discuss this project
1899Year Built
3Stories
S2Building Class
R6AZoning
3,800 sfGross Floor Area
3Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 417 TOMPKINS UNITS LLC · 2,400 sf lot · 1.58 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 3 docs
Floor 1Under Construction5p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WAREHOUSE18 MGMT2306/28/2026
417 TOMPKINS UNITS403/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/03/2019$500K—Private party → 417 TOMPKINS UNITS LLC$132/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THOMAS C. TUNG, P.E.306/11/2025
TWIG CONSULTING ENGINEERS PC502/28/2025
L & C ASSOCIATES110/23/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.803/21/2026
L&C ASSOCIATES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H & K RENOVATION INCGeneral Contractor1207/08/2026
EASTERN BH MECHANICAL INCGeneral Contractor303/21/2026
AMERICAN STANDARD P&H CORORP.Plumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TWIG SPECIAL INSPECTIONS885206/11/2025
JUST CONSULTING ENGINEERI5865402/28/2025
DY SPECIAL INSPECTION LLC7210110/29/2021
Building Lifecycle
All (116)Filed (9)Permit Issued (8)Signed Off (3)Violation (20)Inspection (11)Objection (35)Special Inspection (30)
06/05/2026
Signed off — Alteration
Interior renovation as per plan, there is no change of use, egress and occupancy.
B00829286-I1
01/14/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dave Wall
08/27/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Dave Wall
08/27/2025
Special inspection requirement — Air barrier - visual inspection
THOMAS TUNG
08/27/2025
Special inspection requirement — Lighting controls
THOMAS TUNG
08/27/2025
Special inspection requirement — Interior lighting power
THOMAS TUNG
08/27/2025
Special inspection requirement — Exterior lighting power
THOMAS TUNG
08/27/2025
Special inspection requirement — Fenestration areas
THOMAS TUNG
08/27/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
THOMAS TUNG
08/27/2025
Special inspection requirement — Fenestration air leakage
THOMAS TUNG
08/27/2025
Special inspection requirement — Maintenance information
THOMAS TUNG
07/31/2025
Special inspection requirement — Exterior lighting power
THOMAS TUNG
07/31/2025
Special inspection requirement — Maintenance information
THOMAS TUNG
07/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/11/2025
Filed — Alteration CO
CONVERT EXISTING GARAGE INTO EATING AND DRINKING ESTABLISHMENTS, OBTAIN NEW CERTIFICATION OF OCCUPANCY.
B00907638-P1
05/22/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
04/04/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/04/2025
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
03/27/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/27/2025
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
03/13/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/03/2025
Permit issued — Plumbing
B01188098-I1-PL
03/02/2025
Special inspection requirement — Air barrier - visual inspection
THOMAS TUNG
03/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dave Wall
03/02/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Dave Wall
03/02/2025
Special inspection requirement — Fenestration air leakage
THOMAS TUNG
03/02/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
THOMAS TUNG
03/02/2025
Special inspection requirement — Lighting controls
THOMAS TUNG
03/02/2025
Special inspection requirement — Fenestration areas
THOMAS TUNG
03/02/2025
Special inspection requirement — Interior lighting power
THOMAS TUNG
02/28/2025
Filed — Alteration
INSTALL NEW SEWER, WATER SERVICE AND PLUMBING FIXTURES AT EXISTING 1-STORY BUILDING. THIS PROJECT IS ASSOCIATED WITH CO APPLICATION JOB#B00907638-I1. THERE IS NO GAS WITHIN THIS BUILDING.
B01188098-I1
02/10/2025
Permit issued — General Construction
B00907638-I1-GC
08/12/2024
Objection raised — Scope
08/12/2024
Objection raised — Other
08/12/2024
Objection raised — Admin
08/12/2024
Objection raised — Energy
08/12/2024
Objection raised — Other
08/07/2024
Objection resolved — Addressed
08/07/2024
Objection resolved — Addressed
08/01/2024
Filed — Alteration
INSTALL NEW SEWER, WATER SERVICE AND PLUMBING FIXTURES AT EXISTING 1-STORY BUILDING. THISPROJECT IS ASSOCIATED WITH CO APPLICATION JOB#B00907638-I1. THERE IS NO GAS WITHIN THIS BUILDING.
B01064190-I1
08/01/2024
Objection resolved — Addressed
08/01/2024
Objection resolved — Addressed
08/01/2024
Special inspection requirement — HVAC-R and service water heating equipment
08/01/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
08/01/2024
Special inspection requirement — HVAC-R and service water heating system controls
06/17/2024
Objection raised — Other
12/28/2023
Objection raised — Other
12/22/2023
Objection resolved — Addressed
12/05/2023
Objection resolved — Addressed
10/24/2023
Objection resolved — Addressed
10/24/2023
Objection resolved — Addressed
10/24/2023
Objection resolved — Addressed
10/11/2023
Objection raised — Other
08/23/2023
Objection raised — Scope
08/23/2023
Objection raised — Fire_Protection
08/16/2023
Objection resolved — Addressed
Latest 60 of 116 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.03/03/2025
DOB NOWGeneral ConstructionPermit IssuedH & K RENOVATION INC02/10/2025
DOB NOWGeneral ConstructionSigned-offH & K RENOVATION INC02/16/2023
DOB NOWStructuralSigned-offH & K RENOVATION INC08/29/2022
DOB NOWStructuralSigned-offH & K RENOVATION INC06/29/2022
DOB NOWStructuralSigned-offH & K RENOVATION INC03/28/2022
DOB NOWGeneral ConstructionSigned-offH & K RENOVATION INC11/15/2021
DOB NOWConstruction FencePermit IssuedEASTERN BH MECHANICAL INC11/13/2020
BISEQISSUEDDECOSTA CONSTRUCTION INC07/30/2021
BISEQISSUEDMARK CONTRACTING NY INC07/17/2017
2 projects · most recent 02/28/2025
Storm Water/Sanitary
FiledStatusContractorScope
02/28/2025Permit IssuedAMERICAN STANDARD P&H CORStorm, Water/Sanitary
08/01/2024——Storm, Water/Sanitary
1 project · most recent 03/02/2023
General Wiring
FiledStatusContractorScope
03/02/2023CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
01/14/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/25/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/22/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
04/04/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/04/2025Certified Sprinkler - SP - RoughingCertifiedView ↗
03/27/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/27/2025Certified Sprinkler - SP - RoughingCertifiedView ↗
03/13/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/13/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 42
DateRequirementInspectorRole
08/27/2025Fire-Resistant Penetrations and JointsDave Wallspecial
08/27/2025Structural Stability – Alterations of existing buildingsDave Wallspecial
08/27/2025Air barrier - visual inspectionTHOMAS TUNGenergy_progress
08/27/2025Lighting controlsTHOMAS TUNGenergy_progress
08/27/2025Interior lighting powerTHOMAS TUNGenergy_progress
08/27/2025Exterior lighting powerTHOMAS TUNGenergy_progress
08/27/2025Fenestration areasTHOMAS TUNGenergy_progress
08/27/2025Fenestration and door U-factor and product ratingsTHOMAS TUNGenergy_progress
08/27/2025Fenestration air leakageTHOMAS TUNGenergy_progress
08/27/2025Maintenance informationTHOMAS TUNGenergy_progress
07/31/2025Exterior lighting powerTHOMAS TUNGenergy_progress
07/31/2025Maintenance informationTHOMAS TUNGenergy_progress
03/02/2025Air barrier - visual inspectionTHOMAS TUNGenergy_progress
03/02/2025Fire-Resistant Penetrations and JointsDave Wallspecial
03/02/2025Structural Stability – Alterations of existing buildingsDave Wallspecial
03/02/2025Fenestration air leakageTHOMAS TUNGenergy_progress
03/02/2025Fenestration and door U-factor and product ratingsTHOMAS TUNGenergy_progress
03/02/2025Lighting controlsTHOMAS TUNGenergy_progress
03/02/2025Fenestration areasTHOMAS TUNGenergy_progress
03/02/2025Interior lighting powerTHOMAS TUNGenergy_progress
08/01/2024HVAC-R and service water heating equipment—energy_progress
08/01/2024HVAC-R and service water piping design and insulation—energy_progress
08/01/2024HVAC-R and service water heating system controls—energy_progress
02/14/2023Fire-Resistant Penetrations and JointsXIAOJUN WANGspecial
02/14/2023Interior lighting powerTHOMAS TUNGenergy_progress
Latest 25 of 42.
▾Documents — 82 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch8
08/31/2026B00618532-I1Request digital key ↗
08/31/2026B00621394-P1Request digital key ↗
08/27/2026B00829286-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00417239-I1Request digital key ↗
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION2
08/02/2021321622856Open ↗
07/18/2017321622856Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
05/20/2025322121431Open ↗
07/18/2017321622856Open ↗
▸Seals & Professional Certifications50
▸DOB NOWProgress Inspector Seal & Signature26
08/31/2026B00907638-P1Open ↗
08/31/2026B00907638-P1Open ↗
08/31/2026B00907638-P1Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
08/31/2026B00907638-P1Open ↗
08/31/2026B00907638-P1Open ↗
08/27/2026B00618532-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/31/2026B00618532-I1Open ↗
08/31/2026B00621394-P1Open ↗
08/31/2026B00621394-I1Open ↗
Showing 3 of 9 on file for this type
▸BISProfessional and Owner Certification (POC3)1
07/18/2017321622856Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/18/2017321622856Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/18/2017321622856Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/13/2026B00907638-I1Open ↗
08/13/2026B00907638-P1Open ↗
▸BISTenant Protection Plan and Notes1
07/18/2017321622856Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/22/2026B01188098-I1Open ↗
08/21/2026B00907638-P1Open ↗
08/21/2026B00907638-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/31/2026B00618532-I1Open ↗
08/15/2026B00621394-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00621394-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/02/2021321622856Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
05/20/2025322121431Open ↗
07/19/2017321622856Open ↗
▸BISBOROUGH INTAKE FORM1
08/02/2021321622856Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification2
08/21/2026B00907638-P1Open ↗
08/21/2026B00907638-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00621394-I1Open ↗
08/13/2026B00621394-P1Open ↗