| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 10/03/2022 | $1.1M | — | Private party → Private party | $1,080/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ATOZ CONSULTING ENGINEERS, PC | 5 | 06/23/2026 |
| MORALI ARCHITECTURE | 2 | 12/01/2025 |
| KIEFER & SCHUSTER ENGINEERING PLLC | 1 | 11/26/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| ANTHONY MORALI ARCHITECT PLLC | 14 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MONACO GROUP USA INC | General Contractor | 4 | 07/08/2026 |
| NEXT GENERATION RESTORATION | General Contractor | 4 | 07/08/2026 |
| AMM GEN'L CONTRACTING INC | Plumbing | 1 | 07/08/2026 |
| ODYSSEY PLMBG & HTNG CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ATOZ CONSULTING ENGINEERS | 3303 | 3 | 06/23/2026 |
| ANTHONY MORALI ARCHITECT | 4810 | 4 | 01/09/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | MONACO GROUP USA INC | 03/26/2026 |
| DOB NOW | General Construction | Permit Issued | MONACO GROUP USA INC | 03/26/2026 |
| DOB NOW | Plumbing | Permit Issued | ODYSSEY PLMBG & HTNG CORP | 03/17/2026 |
| DOB NOW | General Construction | Permit Issued | MONACO GROUP USA INC | 01/23/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | MONACO GROUP USA INC | 01/22/2025 |
| DOB NOW | Plumbing | Permit Issued | AMM GEN'L CONTRACTING INC | 05/07/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | NEXT GENERATION RESTORATI | 05/06/2024 |
| DOB NOW | General Construction | Permit Issued | NEXT GENERATION RESTORATI | 04/29/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/23/2026 | Permit Issued | MONACO GROUP USA INC | Air Conditioning Systems | Cooling Mitsubishi Electric MITSUBISHI - MXZ-SM60NL 66,000 BTU · Heat Pump Outdoor ×3 MITSUBISHI - PKFY-L06NLMU-A 6,700 BTU · Vrf Indoor ×3 MITSUBISHI - PKFY-L12NLMU-A 13,500 BTU · Vrf Indoor ×3 MITSUBISHI - TPEFYP012MA144A 13,500 BTU · Vrf Indoor ×3 MITSUBISHI - TPEFYP030MA144A 34,000 BTU · Vrf Indoor ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/23/2026 | Permit Issued | ODYSSEY PLMBG & HTNG CORP | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/23/2026 | Permit Issued | MONACO GROUP USA INC | Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/14/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 04/14/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 04/10/2026 | Pass-Final Sign Permit Inspection | Pass | View ↗ |
| 06/20/2024 | Pass-Final PL - Underground | Pass | View ↗ |
| 04/10/2024 | Pass-Final PL - Underground | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/26/2026 | HVAC-R and service water piping design and insulation | Ilya Malyuchenko | energy_progress |
| 06/26/2026 | Maintenance information | Ilya Malyuchenko | energy_progress |
| 06/26/2026 | HVAC-R and service water heating system controls | Ilya Malyuchenko | energy_progress |
| 06/26/2026 | Energy Code Compliance Inspections | Ilya Malyuchenko | progress |
| 06/26/2026 | Final | Ilya Malyuchenko | progress |
| 06/26/2026 | Mechanical Systems | Ilya Malyuchenko | special |
| 06/26/2026 | HVAC-R and service water heating equipment | Ilya Malyuchenko | energy_progress |
| 01/23/2026 | Fire-Resistant Penetrations and Joints | ANTHONY MORALI | special |
| 01/23/2026 | Energy Code Compliance Inspections | Ilya Malyuchenko | progress |
| 01/23/2026 | Maintenance information | Ilya Malyuchenko | energy_progress |
| 01/23/2026 | HVAC-R and service water heating system controls | Ilya Malyuchenko | energy_progress |
| 01/23/2026 | HVAC-R and service water piping design and insulation | Ilya Malyuchenko | energy_progress |
| 01/23/2026 | HVAC-R and service water heating equipment | Ilya Malyuchenko | energy_progress |
| 01/16/2026 | Interior lighting power | ANTHONY MORALI | energy_progress |
| 01/16/2026 | Fire-Resistant Penetrations and Joints | ANTHONY MORALI | special |
| 01/16/2026 | Fenestration and door U-factor and product ratings | ANTHONY MORALI | energy_progress |
| 01/16/2026 | Fenestration air leakage | ANTHONY MORALI | energy_progress |
| 01/06/2026 | Final | Ilya Malyuchenko | progress |
| 01/06/2026 | Energy Code Compliance Inspections | Ilya Malyuchenko | progress |
| 01/06/2026 | Mechanical Systems | Ilya Malyuchenko | special |
| 01/06/2026 | Fire-Resistant Penetrations and Joints | ANTHONY MORALI | special |
| 01/06/2026 | Energy Code Compliance Inspections | Ilya Malyuchenko | progress |
| 01/06/2026 | HVAC-R and service water heating equipment | Ilya Malyuchenko | energy_progress |
| 01/06/2026 | HVAC-R and service water piping design and insulation | Ilya Malyuchenko | energy_progress |
| 01/06/2026 | Maintenance information | Ilya Malyuchenko | energy_progress |