← Back
Zoned residential, not Manhattan
4738 RICHARDSON AVENUE
BRONX · BIN 2813803
💬 Discuss this project
0Year Built
—Stories
V0Building Class
R4AZoning
0 sfGross Floor Area
0Units
Zoned residential, not Manhattan · Owner of record: VNB DEVELOPMENT LLC · 2,900 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction8p · 1 filing · 20 docs
Floor 1Under Construction8p · 1 filing · 20 docs
CellarUnder Construction19p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/08/2023$280K—Private party → VNB DEVELOPMENT LLC— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW LINE CONSTRUCTION303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BORI CONSTRUCTION CORPGeneral Contractor707/08/2026
DOUG'S PLBG & HTG SERV COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KEYOWNER ENGINEERING, P.C4817404/10/2026
AUTOMATED DESIGN CONSULTA895109/02/2025
Building Lifecycle
All (69)Filed (9)Permit Issued (6)Inspection (2)Objection (22)Special Inspection (30)
08/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/15/2026
Special inspection requirement — Interior lighting power
KWAMI AVITY
05/15/2026
Special inspection requirement — Maintenance information
KWAMI AVITY
05/15/2026
Special inspection requirement — Air barrier - visual inspection
KWAMI AVITY
05/15/2026
Special inspection requirement — Metering
KWAMI AVITY
05/15/2026
Special inspection requirement — Fenestration air leakage
KWAMI AVITY
05/15/2026
Special inspection requirement — Electric vehicle service equipment requirements
KWAMI AVITY
05/15/2026
Special inspection requirement — Permanent certificate
KWAMI AVITY
05/15/2026
Special inspection requirement — Insulation placement and R values
KWAMI AVITY
05/15/2026
Special inspection requirement — Fenestration areas
KWAMI AVITY
05/15/2026
Special inspection requirement — Air barrier — testing
KWAMI AVITY
05/15/2026
Special inspection requirement — Protection of exposed foundation insulation
KWAMI AVITY
05/15/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
KWAMI AVITY
05/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KWAMI AVITY
05/15/2026
Special inspection requirement — Masonry
KWAMI AVITY
05/15/2026
Special inspection requirement — Energy Code Compliance Inspections
KWAMI AVITY
05/15/2026
Special inspection requirement — Fire-Resistance Rated Construction
KWAMI AVITY
04/30/2026
Objection resolved — Addressed
04/21/2026
Objection raised — Other
04/10/2026
Filed — New Building
FO filing in conjunction with new building GC X01083463.
X01083463-P2
04/03/2026
Special inspection requirement — Maintenance information
KWAMI AVITY
04/03/2026
Special inspection requirement — Fire-Resistance Rated Construction
KWAMI AVITY
04/03/2026
Special inspection requirement — Air barrier — testing
KWAMI AVITY
04/03/2026
Special inspection requirement — Insulation placement and R values
KWAMI AVITY
04/03/2026
Special inspection requirement — Fenestration air leakage
KWAMI AVITY
04/03/2026
Special inspection requirement — Metering
KWAMI AVITY
04/03/2026
Special inspection requirement — Air barrier - visual inspection
KWAMI AVITY
04/03/2026
Special inspection requirement — Permanent certificate
KWAMI AVITY
04/03/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
KWAMI AVITY
04/03/2026
Special inspection requirement — Electric vehicle service equipment requirements
KWAMI AVITY
04/03/2026
Special inspection requirement — Protection of exposed foundation insulation
KWAMI AVITY
04/03/2026
Special inspection requirement — Fenestration areas
KWAMI AVITY
04/03/2026
Special inspection requirement — Interior lighting power
KWAMI AVITY
04/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KWAMI AVITY
04/01/2026
Filed — Alteration
New 8'-0" wide curb cut including (2) 1'-6" splays located 371.04' North of the intersection of Richardson Avenue & E 241 Street. New curb cut filed in conjunction with NB #X01083463.
X01182071-I1
03/03/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/18/2026
Permit issued — Mechanical Systems
X01083463-S2-MS
02/12/2026
Permit issued — Plumbing
X01083463-S1-PL
02/04/2026
Filed — New Building
FO filing in conjunction with new building GC X01083463.
X01083463-S1
11/03/2025
Permit issued — Support of Excavation
X01083463-S3-SE
10/24/2025
Permit issued — Foundation
X01083463-S4-FO
10/21/2025
Permit issued — General Construction
X01083463-I1-GC
10/03/2025
Permit issued — Construction Fence
X01182067-I1-FN
09/02/2025
Filed — New Building
FO filing in conjunction with new building GC X01083463.
X01083463-S2
08/15/2025
Objection resolved — Addressed
08/11/2025
Objection raised — Other
08/07/2025
Filed — New Building
FO filing in conjunction with new building GC X01083463.
X01083463-P1
06/05/2025
Filed — Alteration
Temporary Construction Fence to secure property (258.00lf). Construction Fence filed in conjunction with GC #X01083463-I1
X01182067-I1
05/21/2025
Objection resolved — Addressed
05/19/2025
Filed — New Building
FO filing in conjunction with new building GC X01083463.
X01083463-S4
05/19/2025
Objection raised — Other
05/13/2025
Filed — New Building
FO filing in conjunction with new building GC X01083463.
X01083463-S3
02/20/2025
Objection resolved — Addressed
02/20/2025
Objection resolved — Addressed
02/20/2025
Objection resolved — Addressed
10/23/2024
Objection resolved — Addressed
09/20/2024
Objection raised — Other
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
Latest 60 of 69 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedBORI CONSTRUCTION CORP02/18/2026
DOB NOWPlumbingPermit IssuedDOUG'S PLBG & HTG SERV CO02/12/2026
DOB NOWSupport of ExcavationPermit IssuedBORI CONSTRUCTION CORP11/03/2025
DOB NOWFoundationPermit IssuedBORI CONSTRUCTION CORP10/24/2025
DOB NOWGeneral ConstructionPermit IssuedBORI CONSTRUCTION CORP10/21/2025
DOB NOWConstruction FencePermit IssuedBORI CONSTRUCTION CORP10/03/2025
1 project · most recent 04/10/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/10/2026Permit IssuedBORI CONSTRUCTION CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
General Electric AHHS07D3XXA w/FREEZE PROTECTION 6,800 BTU · Ptac ×6
AHHS12D3XXA w/FREEZE PROTECTION 12,200 BTU · Ptac ×3
Cadet CEC163TW 5,115 BTU · Electric Heater ×1
Ventilation
Panasonic FV-0511VHL1 82 CFM · Exhaust Fan ×5
Fantech FIT80E-HC 50 CFM · Erv ×2
FG 4XL EC 50 CFM · Exhaust Fan ×1
Broan SERIES 423001 150 CFM · Kitchen Exhaust ×2
1 project · most recent 04/10/2026
Storm Water/Sanitary
FiledStatusContractorScope
04/10/2026Permit IssuedDOUG'S PLBG & HTG SERV COStorm, Water/Sanitary
1 project · most recent 03/22/2026
General Wiring
FiledStatusContractorScope
03/22/2026Permit IssuedGIA ELECTRICAL CORPGeneral Wiring
1 project · most recent 04/10/2026
FiledStatusContractorScope
04/10/2026Permit IssuedBORI CONSTRUCTION CORP3 scope_items
1 project · most recent 06/05/2025
Fence
FiledStatusContractorScope
06/05/2025Permit IssuedBORI CONSTRUCTION CORPFence
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/07/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/03/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
05/15/2026Interior lighting powerKWAMI AVITYenergy_progress
05/15/2026Maintenance informationKWAMI AVITYenergy_progress
05/15/2026Air barrier - visual inspectionKWAMI AVITYenergy_progress
05/15/2026MeteringKWAMI AVITYenergy_progress
05/15/2026Fenestration air leakageKWAMI AVITYenergy_progress
05/15/2026Electric vehicle service equipment requirementsKWAMI AVITYenergy_progress
05/15/2026Permanent certificateKWAMI AVITYenergy_progress
05/15/2026Insulation placement and R valuesKWAMI AVITYenergy_progress
05/15/2026Fenestration areasKWAMI AVITYenergy_progress
05/15/2026Air barrier — testing KWAMI AVITYenergy_progress
05/15/2026Protection of exposed foundation insulationKWAMI AVITYenergy_progress
05/15/2026Fenestration and door U-factor and product ratingsKWAMI AVITYenergy_progress
05/15/2026Fire-Resistant Penetrations and JointsKWAMI AVITYspecial
05/15/2026MasonryKWAMI AVITYspecial
05/15/2026Energy Code Compliance InspectionsKWAMI AVITYprogress
05/15/2026Fire-Resistance Rated ConstructionKWAMI AVITYprogress
04/03/2026Maintenance informationKWAMI AVITYenergy_progress
04/03/2026Fire-Resistance Rated ConstructionKWAMI AVITYprogress
04/03/2026Air barrier — testing KWAMI AVITYenergy_progress
04/03/2026Insulation placement and R valuesKWAMI AVITYenergy_progress
04/03/2026Fenestration air leakageKWAMI AVITYenergy_progress
04/03/2026MeteringKWAMI AVITYenergy_progress
04/03/2026Air barrier - visual inspectionKWAMI AVITYenergy_progress
04/03/2026Permanent certificateKWAMI AVITYenergy_progress
04/03/2026Fenestration and door U-factor and product ratingsKWAMI AVITYenergy_progress
Latest 25 of 44.
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/19/2026X01182067-I1Request digital key ↗
08/17/2026X01182071-I1Request digital key ↗
08/17/2026X01083463-S2Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026X01083463-I1Open ↗
08/15/2026X01083463-P2Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/15/2026X01083463-I1Open ↗
08/15/2026X01083463-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026X01083463-I1Open ↗
▸Seals & Professional Certifications20
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/19/2026X01182067-I1Open ↗
08/17/2026X01182071-I1Open ↗
08/17/2026X01083463-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/01/2026X01083463-I1Open ↗
09/01/2026X01083463-I1Open ↗
09/01/2026X01083463-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026X01083463-I1Open ↗
08/28/2026X01083463-S3Open ↗
08/28/2026X01083463-S3Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/15/2026X01083463-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/15/2026X01083463-I1Open ↗
08/15/2026X01083463-P2Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026X01083463-I1Open ↗
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT3
08/13/2026X01083463-S3Open ↗
08/13/2026X01083463-S4Open ↗
08/13/2026X01083463-P1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/13/2026X01083463-S4Open ↗
08/13/2026X01083463-S3Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026X01083463-S3Open ↗
08/13/2026X01083463-S4Open ↗
▸Other Documents7
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026X01083463-I1Open ↗
08/15/2026X01083463-P2Open ↗
▸DOB NOWSite Survey: Initial2
08/15/2026X01083463-I1Open ↗
08/15/2026X01083463-P2Open ↗
▸DOB NOWProperty Ownership Certification2
08/15/2026X01083463-I1Open ↗
08/15/2026X01083463-P2Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X01083463-S3Open ↗