HPD09/09/2026§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES IN THE ENTIRE APARTMENT LOCATED AT APT 16B, 15th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD09/09/2026§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS IMPROPERLY MOUNTED IN THE ENTIRE APARTMENT LOCATED AT APT 16B, 15th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD09/09/2026§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE
HPD07/14/2026§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ROOM LOCATED AT B-ROOM 14D, 13th STORY, 1st B-ROOM FROM WEST AT NORTH
HPD07/14/2026§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ROOM LOCATED AT B-ROOM 14D, 13th STORY, 1st B-ROOM FROM WEST AT NORTH
HPD12/12/2025§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 15D, 15th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''u141''
HPD12/12/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10 SQ FT AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 14D1, 14th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''unit141'' ORIGINAL VIOLATION 18502406 ISSUED 12-DEC-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
HPD12/12/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL, THE SOUTH WALL AND THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 15D, 15th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''u141''
HPD12/12/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 15D, 15th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''u141''
HPD12/12/2025§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 14D1, 14th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''unit141''
HPD06/16/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD06/16/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 5th ROOM FROM EAST AT SOUTH LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD03/28/2025§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ROOM LOCATED AT B-ROOM 6B3, 6th STORY, 2nd B-ROOM FROM SOUTH AT WEST