← Back
Dormitory
Weinstein Residence Hall
5 UNIVERSITY PLACE · Greenwich Village · BIN 1080105
💬 Discuss this project
1962Year Built
9Stories
H8Building Class
R7-2Zoning
116,237 sfGross Floor Area
302Units
LL97 CoveredRent Stabilized2 Open Violations ▸FISP: SAFE
Dormitory · Owner of record: NEW YORK UNIVERSITY · 22,220 sf lot · 5.23 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionEquipmentGeneral
Permit Issued — active, not yet Signed-off
Roof10p · 3 filings · 20 docs
Floor 1Under Construction102p · 6 filings · 20 docs
Cellar57p · 2 filings · 20 docs
Sub-Cellar6p · 1 filing · 7 docs
Site & exterior7p · 3 filings · 11 docs
Filed — no permit issued54p · 4 filings · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK UNIVERSITY10109/08/2026
SPRING SCAFFOLDING LLC303/21/2026
NYU OFFICE OF CONSTRUCTION203/21/2026
N Y U SCHOOL OF LAW FOUNDATION203/21/2026
TURNER CONSTRUCTION103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A E C CONSULTING EXPEDITING2403/21/2026
JM ZONING, LLC.203/21/2026
AE DESIGN SOLUTION203/21/2026
BURNHAM NATIONWIDE INC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PJP INSTALLERS INCGeneral Contractor607/08/2026
TECTONIC BUILDERS INCGeneral Contractor607/08/2026
DNA CONTRACTING LLCGeneral Contractor307/08/2026
LAWRENCE J. LEVINEFire Protection203/21/2026
PAR PLUMBING CO., INCPlumbing207/08/2026
BROSNA CONSTRUCTION CORPOGeneral Contractor207/08/2026
ANESIS SERVICES CORPFire Protection105/29/2026
SKYLINE FIRE SPRINKLER COFire Protection107/08/2026
HUDSON PLMBING & MCH, LLCPlumbing107/08/2026
BIGMAN BROS., INC.Electrical103/22/2026
SMART PLBG & HTG CORPPlumbing107/08/2026
JOHN DICAPUAElectrical103/21/2026
KING, ARTHURElectrical103/21/2026
PIMPINELLA, FRANKElectrical103/21/2026
SCOTT BIGMANElectrical103/21/2026
STEPHEN ROSTOWSKYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RICHMOND TESTING LAB263505/14/2026
EC SPECIAL INSPECTIONS8355101/07/2025
GUTH DECONZO CONSULTING E1210501/22/2024
Building Lifecycle
All (177)Filed (20)Permit Issued (18)Signed Off (9)Facade (FISP) (12)Violation (60)Inspection (13)Objection (15)Special Inspection (30)
08/24/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/28/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/22/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/22/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/10/2026
Permit issued — Sprinklers
M01391173-S2-PL
05/28/2026
Permit issued — Sprinklers
M01391173-S2-EW-SP
05/22/2026
Permit issued — Mechanical Systems
M01391173-S1-MS
05/18/2026
Permit issued — General Construction
M01391173-I1-GC
05/14/2026
Filed — Alteration
Filing herewith plumbing and sprinkler modifications as per plans
M01391173-S1
05/08/2026
Filed — Alteration
Filing herewith plumbing and sprinkler modifications as per plans
M01391173-S2
05/06/2026
Filed — Alteration
Filing herewith plumbing and sprinkler modifications as per plans
M01391173-I1
04/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Post-installed Anchors
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Sprinkler Systems
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Lighting controls
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Interior lighting power
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Fire-Resistance Rated Construction
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Final
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
RICHARD LEMANSKY
04/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
RICHARD LEMANSKY
03/20/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/06/2026
Permit issued — Plumbing
M01130204-I1-PL
02/07/2025
Signed off — Alteration
Installation of new sprinkler heads, relocation and cap/remove existing heads on 1st floor as per plans.
M00746531-I1
01/31/2025
Signed off — Alteration
Mechanical work as per plans on 1st floor and roof of the 1st floor.
M00746621-I1
01/30/2025
Objection resolved — Addressed
01/15/2025
Signed off — Alteration
Installation and modification of plumbing fixtures and related piping as per plans.
M00746567-I1
01/15/2025
Objection raised — Energy
01/07/2025
Filed — Alteration
Plumbing work filed for the installation of new water heater as per plans. No change in use egress or occupancy.
M01130204-I1
01/06/2025
Special inspection requirement — High Temperature Hot Water Piping (Welding)
RICHARD LEMANSKY
11/01/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
RICHARD LEMANSKY
10/21/2024
Special inspection requirement — Tenant Protection Plan Compliance
ABDALLAH ELCHERBINI
04/04/2024
Signed off — Alteration
This application is being filed for Interior Demo on the Cellar and First Floor and Construction of partitions and finish work on the Cellar and First Floor as per plans at the subject premises. There is no change in use, egress or occupancy.
M00735063-I1
01/31/2024
Permit issued — Plumbing
M00746567-I1-PL
01/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Guth
01/22/2024
Filed — Alteration
Installation and modification of plumbing fixtures and related piping as per plans.
M00746567-P2
10/05/2023
Signed off — Alteration
Filing herewith application for facade repairs as per plan submitted. No change in use, egress or occupancy.
M00728258-I1
05/04/2023
Permit issued — General Construction
M00735063-I1-GC
04/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Guth
03/15/2023
Violation issued (HPD, closed)
A
02/21/2023
Cycle 9 facade report submitted
02/21/2023
Cycle 9 facade report signed — SAFE
01/30/2023
Cycle 9 facade inspection completed
01/03/2023
Signed off — Alteration
STORAGE ON SIDEWALK SHED DRAWINGS IN CONJUNCTION WITH JOB # M00728258. NO CHANGE IN USE, EGRESS, OCCUPANCY.
M00783257-I1
01/03/2023
Signed off — Alteration
M00783238-I1
12/20/2022
Permit issued — General Construction
M00728258-I1-GC
09/12/2022
Filed — Alteration
Installation and modification of plumbing fixtures and related piping as per plans.
M00746567-P1
09/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Guth
08/31/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/26/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/26/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/24/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/15/2022
Permit issued — Sidewalk Shed
M00783238-I1-SH
08/14/2022
Permit issued — Protection and Mechanical Methods
M00783257-I1-PM
08/12/2022
Filed — Alteration
STORAGE ON SIDEWALK SHED DRAWINGS IN CONJUNCTION WITH JOB # M00728258. NO CHANGE IN USE, EGRESS, OCCUPANCY.
M00783257-I1
08/12/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/11/2022
Filed — Alteration
M00783238-I1
08/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/22/2022
Permit issued — General Construction
M00728258-I1-GC
07/19/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
Latest 60 of 177 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedHUDSON PLMBING & MCH, LLC06/10/2026
DOB NOWSprinklersPermit IssuedANESIS SERVICES CORP05/28/2026
DOB NOWMechanical SystemsPermit IssuedBROSNA CONSTRUCTION CORPO05/22/2026
DOB NOWGeneral ConstructionPermit IssuedBROSNA CONSTRUCTION CORPO05/18/2026
DOB NOWPlumbingSigned-offSMART PLBG & HTG CORP03/06/2026
DOB NOWPlumbingSigned-offPAR PLUMBING CO., INC01/31/2024
DOB NOWGeneral ConstructionSigned-offTECTONIC BUILDERS INC05/04/2023
DOB NOWGeneral ConstructionSigned-offPAUL CHARLTON12/20/2022
DOB NOWSidewalk ShedSigned-offPJP INSTALLERS INC08/15/2022
DOB NOWProtection and Mechanical MethodsSigned-offPJP INSTALLERS INC08/14/2022
DOB NOWGeneral ConstructionSigned-offPAUL CHARLTON07/22/2022
DOB NOWPlumbingSigned-offPAR PLUMBING CO., INC06/21/2022
DOB NOWMechanical SystemsSigned-offTECTONIC BUILDERS INC06/15/2022
DOB NOWSprinklersSigned-offSKYLINE FIRE SPRINKLER CO06/14/2022
DOB NOWGeneral ConstructionSigned-offTECTONIC BUILDERS INC05/16/2022
DOB NOWGeneral ConstructionSigned-offTECTONIC BUILDERS INC06/10/2021
DOB NOWSidewalk ShedSigned-offPJP INSTALLERS INC12/31/2018
DOB NOWSidewalk ShedSigned-offPJP INSTALLERS INC10/24/2018
BISOTISSUEDSATO CONSTRUCTION CO.INC01/10/2019
BISSPISSUEDGO PRO FIRE PROTECTION C12/12/2016
BISSPISSUEDGO PRO FIRE PROTECTION C08/03/2015
BISPLISSUEDACCURATE MECHANICAL INC06/24/2015
BISOTISSUEDBROSNA CONSTRUCTION CORPO06/09/2015
BISMHISSUEDBROSNA CONSTRUCTION CORPO06/09/2015
BISPLISSUEDPAR PLUMBING CO., INC05/04/2015
BISOTISSUEDLRP CONSTRUCTION CORP03/27/2015
BISMHISSUEDLRP CONSTRUCTION CORP03/27/2015
BISEQISSUEDLRP CONSTRUCTION CORP03/27/2015
BISEQISSUEDSKYLINE RESTORATION INC08/21/2014
BISPLISSUEDDUO PLUMBING & HTG CORP.08/18/2014
BISOTISSUEDJVT ENTERPRISES INC08/14/2014
BISOTISSUEDSKYLINE RESTORATION INC06/27/2014
BISSPISSUEDTOWER FIRE PROTECTION INC06/10/2014
BISPLISSUEDPAR PLUMBING CO., INC06/02/2014
BISOTISSUEDTURNER CONSTRUCTION COMPANY05/21/2014
BISOTISSUEDSKYLINE RESTORATION INC05/21/2014
BISMHISSUEDTURNER CONSTRUCTION COMPANY05/21/2014
BISEQISSUEDSPRING SCAFFOLDING LLC05/20/2014
BISSPISSUEDJAM SERVICE CO., INC05/06/2014
BISMHISSUEDLRP CONSTRUCTION CORP03/27/2014
+ 28 more permits on file
1 project · most recent 04/22/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/22/2022——Heating and Air Conditioning Systems
Heat / Cool
Lg ARNU153TQD4 38,000 BTU · Vrf Indoor ×1
2 projects · most recent 05/14/2026
FiledStatusContractorScope
05/14/2026Permit IssuedTHOMAS FAY33 heads
05/03/2022——66 heads
2 projects · most recent 05/14/2026
Water/Sanitary
FiledStatusContractorScope
05/14/2026Permit IssuedHUDSON PLMBING & MCH, LLCWater/Sanitary
01/07/2025Signed-offSMART PLBG & HTG CORPWater/Sanitary
8 projects · most recent 06/12/2026
General Wiring
FiledStatusContractorScope
06/12/2026Permit IssuedJUMPER ELECTRIC CORPGeneral Wiring
03/19/2026CompleteCAPUTEK ELEC'L SERVICES,—
04/04/2025CompleteBIGMAN BROS., INC.General Wiring
07/28/2022CompleteTOP SHELF ELECTRIC CORP—
06/08/2022CompleteARCADIA ELECT'L CO. INC.General Wiring
05/16/2022Permit IssuedARCADIA ELECT'L CO. INC.—
04/08/2022CompleteMHO'S ELECTRIC CORPGeneral Wiring
10/18/2018CompleteTOP SHELF ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
08/24/2026Fail-Final General Construction Non-Directive 14FailView ↗
07/28/2026Fail-Final General Construction Non-Directive 14FailView ↗
07/22/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/22/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/10/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/20/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/31/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/26/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/26/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/24/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/12/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/19/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
04/22/2026Tenant Protection Plan ComplianceRICHARD LEMANSKYspecial
04/22/2026Post-installed AnchorsRICHARD LEMANSKYspecial
04/22/2026Sprinkler SystemsRICHARD LEMANSKYspecial
04/22/2026Lighting controlsRICHARD LEMANSKYenergy_progress
04/22/2026Interior lighting powerRICHARD LEMANSKYenergy_progress
04/22/2026Fire-Resistance Rated ConstructionRICHARD LEMANSKYprogress
04/22/2026FinalRICHARD LEMANSKYprogress
04/22/2026Fire-Resistant Penetrations and JointsRICHARD LEMANSKYspecial
04/22/2026Tenant Protection Plan ComplianceRICHARD LEMANSKYspecial
01/06/2025High Temperature Hot Water Piping (Welding)RICHARD LEMANSKYspecial
11/01/2024HVAC-R and service water piping design and insulationRICHARD LEMANSKYenergy_progress
10/21/2024Tenant Protection Plan ComplianceABDALLAH ELCHERBINIspecial
01/24/2024Fire-Resistant Penetrations and JointsJohn Guthspecial
04/14/2023Fire-Resistant Penetrations and JointsJohn Guthspecial
09/06/2022Fire-Resistant Penetrations and JointsJohn Guthspecial
06/02/2022FinalHANS ERDENBERGERprogress
05/26/2022HVAC-R and service water piping design and insulationJohn Guthenergy_progress
05/26/2022Maintenance informationJohn Guthenergy_progress
05/26/2022Fire-Resistant Penetrations and JointsJohn Guthspecial
05/26/2022Mechanical SystemsJohn Guthspecial
05/26/2022Sprinkler SystemsJohn Guthspecial
05/26/2022FinalJohn Guthprogress
05/26/2022Energy Code Compliance InspectionsJohn Guthprogress
05/26/2022HVAC-R and service water heating system controlsJohn Guthenergy_progress
05/26/2022HVAC-R and service water heating equipmentJohn Guthenergy_progress
Latest 25 of 33.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Chartwells Dining ServicesRestaurant / Food ServiceFloor 1
Project M00746621 Alteration · LOC Issued · 06/06/2022
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 536 on file (BIS + DOB NOW)
▸Plans & Drawings20
▸DOB NOWPlans/Sketch20
09/06/2026M00090144-I1Request digital key ↗
09/03/2026M00521866-I1Request digital key ↗
09/02/2026M00700702-I1Request digital key ↗
Showing 3 of 20 on file for this type
▸Applications & Permits87
▸BISPLAN / WORK APPROVAL APPLICATION47
09/25/2018123515552Open ↗
07/13/2015122192386Open ↗
06/16/2015122380967Open ↗
Showing 3 of 47 on file for this type
▸BISWORK PERMIT APPLICATION37
01/14/2019123515552Open ↗
11/08/2018123515552Open ↗
12/27/2016122380967Open ↗
Showing 3 of 37 on file for this type
▸BISPLACE OF ASSEMBLY3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸Seals & Professional Certifications133
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION51
11/21/2019123515552Open ↗
11/21/2019123515552Open ↗
11/15/2019123515552Open ↗
Showing 3 of 51 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature20
09/06/2026M00090144-I1Open ↗
09/02/2026M00679130-I1Open ↗
09/02/2026M00700702-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/23/2026M00679130-I1Open ↗
09/01/2026M01391173-I1Open ↗
09/01/2026M01391173-I1Open ↗
Showing 3 of 14 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST13
09/25/2018123515552Open ↗
06/16/2015122380967Open ↗
07/30/2014122077260Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/20/2026M00746567-I1Open ↗
09/01/2026M00746567-P1Open ↗
09/01/2026M01391173-I1Open ↗
Showing 3 of 12 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT10
09/25/2018123515552Open ↗
06/16/2015122380967Open ↗
08/20/2014140243760Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/20/2014140243760Open ↗
Showing 1 of 2 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
08/20/2014140243760Open ↗
Showing 1 of 2 on file for this type
▸BISProfessional and Owner Certification (POC3)1
06/16/2015122380967Open ↗
▸Trade Schedules & Equipment57
▸BISSELF-CERT PLUMBING NOTICE20
11/10/2015122380967Open ↗
11/02/2015122380967Open ↗
09/09/2015122380967Open ↗
Showing 3 of 20 on file for this type
▸BISSCHEDULE B - PLUMBING13
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 13 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE7
06/16/2015122380967Open ↗
12/08/2014122016219Open ↗
07/30/2014122077260Open ↗
Showing 3 of 7 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA7
12/28/2017122192386Open ↗
07/13/2015122192386Open ↗
Showing 2 of 7 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT5
02/28/2023122016219Open ↗
06/05/2019110066099Open ↗
06/05/2019110066099Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE PERMITS3
02/28/2023122016219Open ↗
06/05/2019110066099Open ↗
06/05/2019110066099Open ↗
▸BISSPRINKLER INSP REPORT : FP-852
11/10/2015122380967Open ↗
Showing 1 of 2 on file for this type
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
09/25/2018123515552Open ↗
▸Environmental & Asbestos45
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
09/02/2026M00700702-I1Open ↗
09/02/2026M00735063-P1Open ↗
09/02/2026M00735063-I1Open ↗
Showing 3 of 17 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)15
11/21/2019123515552Open ↗
11/21/2019123515552Open ↗
07/13/2015122192386Open ↗
Showing 3 of 15 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)6
11/15/2019123515552Open ↗
11/15/2019123515552Open ↗
11/14/2019123515552Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDEP FORM V5 - ASBESTOS VARIANCE1
11/08/2018123515552Open ↗
▸Energy Compliance39
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS22
11/21/2019123515552Open ↗
11/21/2019123515552Open ↗
11/15/2019123515552Open ↗
Showing 3 of 22 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS9
11/21/2019123515552Open ↗
11/15/2019123515552Open ↗
11/14/2019123515552Open ↗
Showing 3 of 9 on file for this type
▸BISTR8: Energy Code Progress Inspections2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
02/10/2023122016219Open ↗
▸BISLIGHTING CONTROLS1
02/10/2023122016219Open ↗
▸BIS* HVAC INSULATION AND SEALING1
02/10/2023122016219Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
02/10/2023122016219Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWEN2: As Built Energy Analysis1
09/02/2026M00746621-I1Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/20/2014140243760Open ↗
▸BISMECHANICAL SYSTEMS1
02/10/2023122016219Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
02/10/2023122016219Open ↗
▸BIS* EXIT SIGNS1
02/10/2023122016219Open ↗
▸Approvals, Objections & Sign-offs53
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST22
02/14/2020110066099Open ↗
11/22/2019123515552Open ↗
11/21/2019123515552Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter17
09/02/2026M00700702-I1Open ↗
09/02/2026M00735063-P1Open ↗
09/02/2026M00735063-I1Open ↗
Showing 3 of 17 on file for this type
▸BISADMINISTRATIVE OBJECTIONS12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISFINAL1
02/10/2023122016219Open ↗
▸BISSUPERSEDING LETTER1
04/18/2019121955544Open ↗
▸Cost, Insurance & Ownership41
▸BISCOST AFFIDAVIT40
11/21/2019123515552Open ↗
11/15/2019123515552Open ↗
11/14/2019123515552Open ↗
Showing 3 of 40 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
02/10/2023122016219Open ↗
▸Filing & Intake Forms44
▸BISEFILING COVER SHEET23
09/25/2018123515552Open ↗
07/13/2015122192386Open ↗
06/16/2015122380967Open ↗
Showing 3 of 23 on file for this type
▸BISBOROUGH INTAKE FORM10
02/14/2020110066099Open ↗
11/22/2019123515552Open ↗
11/21/2019123515552Open ↗
Showing 3 of 10 on file for this type
▸BISADDITIONAL INFORMATION8
12/12/2014122016219Open ↗
09/06/2014121955544Open ↗
06/11/2014122016219Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
08/20/2014140243760Open ↗
Showing 1 of 3 on file for this type
▸Other Documents12
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION7
09/25/2018123515552Open ↗
07/28/2014122077260Open ↗
06/04/2014122016219Open ↗
Showing 3 of 7 on file for this type
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
06/18/2015122380967Open ↗
Showing 1 of 2 on file for this type
▸BISFEE EXEMPTION DOCUMENTATION2
08/20/2014140243760Open ↗
Showing 1 of 2 on file for this type
▸BISSupporting Document: Fee Deferment1
07/13/2015122192386Open ↗