← Back
BuildNYC
MANHATTAN
East Village Ab Condominium
500 EAST 14TH STREET · East Village · BIN 1090249
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Active ViolationsFISP: SWARMPFDNY Report ↗
Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 5Solidcore3p · 2 filings · 4 docs
Floor 4Solidcore3p · 2 filings · 4 docs
Floor 3Solidcore3p · 2 filings · 4 docs
Floor 2Solidcore3p · 2 filings · 4 docs
Floor 1CorePower Yoga, Tumi +179p · 14 filings · 20 docs
CellarExtell Development3p · 2 filings · 15 docs
Site & exteriorCorePower Yoga, Target7p · 7 filings · 20 docs
Filed — no permit issuedRADIOLOGY MEDICALARTS illuminated business wall sign install1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
East Village 149903/21/2026
Extell Developement6507/08/2026
Lighthouse Properties203/21/2026
14th Street Medical103/22/2026
555 Tenth Ave103/22/2026
Buch Construction103/22/2026
118 Third Ave103/21/2026
Empire Associates Realty103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Somma Design Consulting403/21/2026
Gregg Rothstein Architect503/21/2026
J.A.M. Associates2203/21/2026
Louis Striar603/21/2026
Building Brothers1003/21/2026
CSMR Designs103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Select Commercial Construction*General Contractor1107/08/2026
National MaintenanceSign hanger507/08/2026
Forest Brook Electrical ContractingElectrical203/22/2026
Louis L.buttermark & SonsFire Protection207/08/2026
B.R. Fries & AssociatesGeneral Contractor203/21/2026
Delta HVACspecialty_contractor207/08/2026
Z-Car-DSign hanger207/08/2026
Retail ExpertsGeneral Contractor207/08/2026
Rite Way Plumbing & HeatingPlumbing107/08/2026
Village P & H NYPlumbing107/08/2026
Acm ElectricElectrical103/22/2026
Village P & H NYFire Protection107/08/2026
Interstate ElectricElectrical103/22/2026
Select Commercial Construction*Scaffold107/08/2026
Signstar NYCSign hanger107/08/2026
Alma Plumbing SprinklerFire Protection107/08/2026
Buckmiller Automatic SprinklerFire Protection107/08/2026
Liquid Plumbing & Heating SCSPlumbing107/08/2026
Louis L.buttermark & SonsPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Catalpa Special Inspectio2004211/20/2025
Vincent J. Liotta P. E1974411/19/2025
Skyline Engineering267405/26/2022
Ryan Special Engineering2018502/12/2021
Special Inspection Services1200209/16/2020
Building Lifecycle
All (201)Filed (33)Permit Issued (28)Signed Off (16)Facade (FISP) (6)Violation (60)Inspection (8)Objection (20)Special Inspection (30)
07/31/2026
Cycle 10 facade report submitted
07/31/2026
Cycle 10 facade report signed — SAFE
07/08/2026
Cycle 10 facade inspection completed
12/24/2025
Signed off — Alteration
ALTERATION FOR INTERIOR WORK TO NON-BEARING PARTITIONS AT FIRST FLOOR. NO CHANGE OF BULK, USE, OCCUPANCY OR EGRESS. MS, PL, AND SP APPLICATIONS FILED SEPARATELY.
M01212731-I1
12/23/2025
Signed off — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-S2
12/05/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/02/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/25/2025
Signed off — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-I1
11/25/2025
Signed off — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-S1
11/20/2025
Filed — Alteration
ALTERATION FOR INTERIOR WORK TO NON-BEARING PARTITIONS AT FIRST FLOOR. NO CHANGE OF BULK, USE, OCCUPANCY OR EGRESS. MS, PL, AND SP APPLICATIONS FILED SEPARATELY.
M01212731-P1
11/20/2025
Filed — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-P3
11/20/2025
Special inspection requirement — Sprinkler Systems
Vincent Liotta
11/19/2025
Filed — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-P2
11/19/2025
Filed — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-P1
11/05/2025
Special inspection requirement — Sprinkler Systems
Vincent Liotta
11/05/2025
Special inspection requirement — Tenant Protection Plan Compliance
11/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
Vincent Liotta
11/05/2025
Special inspection requirement — Final
Vincent Liotta
11/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
Vincent Liotta
11/05/2025
Special inspection requirement — Interior lighting power
ERIC BERLENT
11/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
11/05/2025
Special inspection requirement — Fire-Resistance Rated Construction
ERIC BERLENT
11/05/2025
Special inspection requirement — Final
ERIC BERLENT
11/05/2025
Special inspection requirement — Lighting controls
ERIC BERLENT
11/05/2025
Special inspection requirement — Maintenance information
Vincent Liotta
11/05/2025
Special inspection requirement — Energy Code Compliance Inspections
ERIC BERLENT
11/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Vincent Liotta
11/05/2025
Special inspection requirement — Mechanical Systems
Vincent Liotta
10/28/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/16/2025
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - COREPOWER YOGA. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01254062-I1
09/05/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/17/2025
Permit issued — Sign
M01254062-I1-SG
07/16/2025
Filed — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - COREPOWER YOGA. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01254062-I1
07/16/2025
Special inspection requirement — Final
Richard Wainer
07/03/2025
Permit issued — Sprinklers
M01219995-S2-EW-SP
07/01/2025
Permit issued — Plumbing
M01219995-S1-PL
06/30/2025
Permit issued — Mechanical Systems
M01219995-I1-MS
06/30/2025
Permit issued — General Construction
M01212731-I1-GC
06/05/2025
Objection resolved — Addressed
06/05/2025
Objection resolved — Addressed
06/05/2025
Objection resolved — Addressed
06/05/2025
Objection resolved — Addressed
06/05/2025
Objection resolved — Addressed
06/05/2025
Objection resolved — Addressed
05/12/2025
Filed — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-S2
05/12/2025
Filed — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-I1
05/12/2025
Filed — Alteration
REPLACEMENT OF EXISTING SPRINKLER HEADS WITH 47 HIGH TEMPRATURE SPRINKLER HEADS (30 CONCEALED HEADS AND 17 UPRIGHT HEADS). NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01219995-S1
05/12/2025
Objection raised — Other
05/12/2025
Objection raised — Structural
05/12/2025
Objection raised — Scope
05/12/2025
Objection raised — Structural
05/12/2025
Objection raised — Plumbing
05/12/2025
Objection raised — Structural
05/08/2025
Filed — Alteration
ALTERATION FOR INTERIOR WORK TO NON-BEARING PARTITIONS AT FIRST FLOOR. NO CHANGE OF BULK, USE, OCCUPANCY OR EGRESS. MS, PL, AND SP APPLICATIONS FILED SEPARATELY.
M01212731-I1
08/13/2024
Signed off — Alteration
Erect construction fence 3 feet from property line.
M00667872-I1
05/21/2024
Signed off — Alteration
M00667893-I1
10/11/2023
Violation issued (FDNY_NOV, closed)
08/11/2023
Violation issued (FDNY_NOV, closed)
02/17/2023
Cycle 9 facade report submitted
02/17/2023
Cycle 9 facade report signed — SWARMP
Latest 60 of 201 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignSigned-offSignstar NYC07/17/2025
DOB NOWSprinklersSigned-offBuckmiller Automatic Sprinkler07/03/2025
DOB NOWPlumbingSigned-offLiquid Plumbing & Heating SCS07/01/2025
DOB NOWMechanical SystemsSigned-offRetail Experts06/30/2025
DOB NOWGeneral ConstructionSigned-offRetail Experts06/30/2025
DOB NOWGeneral ConstructionPermit IssuedSelect Commercial Construction*08/12/2022
DOB NOWGeneral ConstructionPermit IssuedSelect Commercial Construction*08/12/2022
DOB NOWGeneral ConstructionPermit IssuedSelect Commercial Construction*08/04/2022
DOB NOWSignSigned-offZ-Car-D06/24/2022
DOB NOWSignSigned-offZ-Car-D06/23/2022
DOB NOWStructuralPermit IssuedSelect Commercial Construction*06/03/2022
DOB NOWMechanical SystemsPermit IssuedSelect Commercial Construction*04/20/2022
DOB NOWPlumbingSigned-offVillage P & H NY04/20/2022
DOB NOWSprinklersSigned-offVillage P & H NY04/20/2022
DOB NOWConstruction FenceSigned-offSelect Commercial Construction*04/08/2022
DOB NOWSprinklersPermit IssuedLouis L.buttermark & Sons09/30/2021
DOB NOWMechanical SystemsSigned-offB.R. Fries & Associates10/05/2020
DOB NOWSprinklersPermit IssuedLouis L.buttermark & Sons09/29/2020
DOB NOWPlumbingPermit IssuedLouis L.buttermark & Sons09/25/2020
DOB NOWMechanical SystemsSigned-offDelta HVAC06/12/2020
DOB NOWSprinklersSigned-offSmart Plumbing & Heating06/11/2020
DOB NOWMechanical SystemsSigned-offDelta HVAC05/19/2020
DOB NOWPlumbingSigned-offRite Way Plumbing & Heating01/29/2020
DOB NOWSignSigned-offNational Maintenance05/10/2018
DOB NOWSignSigned-offNational Maintenance05/09/2018
DOB NOWSignSigned-offNational Maintenance05/09/2018
DOB NOWSignSigned-offNational Maintenance05/09/2018
DOB NOWSignSigned-offNational Maintenance05/09/2018
BISOTISSUEDB.R. Fries & Associates09/06/2020
BISOTISSUEDAlco Store Development01/22/2020
BISOTISSUEDLeeding Builders Group08/17/2018
BISOTISSUEDWinick Productions07/19/2018
BIS—ISSUEDLeeding Builders Group03/28/2018
BISOTISSUEDLeeding Builders Group02/02/2018
BISOTISSUEDLeeding Builders Group02/02/2018
BISSPISSUEDVanguard Fire Supp02/01/2018
BISPLISSUEDTristate Plumbing Services01/03/2018
BISMHISSUEDB.R. Fries & Associates12/27/2017
BISOTRE-ISSUEDB.R. Fries & Associates12/27/2017
BISOTRE-ISSUEDB.R. Fries & Associates12/27/2017
+ 38 more permits on file
2 projects · most recent 04/05/2022
Air Conditioning Systems Ventilation Systems Associated Ducts and Piping
FiledStatusContractorScopeMake / Model / Capacity
04/05/2022Permit IssuedSelect Commercial Construction*Air Conditioning Systems, Ventilation Systems
Cooling
Carrier 50HQP072 2,600 CFM · Heat Pump Outdoor ×1
50PCH048 1,430 CFM · Heat Pump Outdoor ×1
Ventilation
Acme VQ080ES 75 CFM · Exhaust Fan ×2
09/16/2020Signed-offB.R. Fries & AssociatesAssociated Ducts and Piping
Ducts & Piping
N/A N/A 1 BTU · Ductwork ×1
11 projects · most recent 01/29/2026
General Wiring
FiledStatusContractorScope
01/29/2026CompleteProsto ElectricGeneral Wiring
07/18/2025CompleteProff Electrical—
07/15/2022Permit IssuedIsland Electric—
05/05/2022CompleteInterstate ElectricGeneral Wiring
06/28/2021CompleteAcm ElectricGeneral Wiring
11/10/2020CompleteForest Brook Electrical Contracting3 meters, 1 new_meters
08/26/2020CompleteForest Brook Electrical ContractingGeneral Wiring
08/21/2020CompleteBigman BrothersGeneral Wiring
08/11/2020CompleteAntonio Ceriello Electric—
05/21/2018CompleteRockmor Electric EnterprisesGeneral Wiring
04/23/2018CompleteRoma ElectricGeneral Wiring
1 project · most recent 05/26/2022
Concrete
FiledStatusContractorScope
05/26/2022Permit IssuedSelect Commercial Construction*Concrete
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
12/05/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/02/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/28/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/05/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/10/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/30/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/26/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/28/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 61
DateRequirementInspectorRole
11/20/2025Sprinkler SystemsVincent Liottaspecial
11/05/2025Sprinkler SystemsVincent Liottaspecial
11/05/2025Tenant Protection Plan Compliance—special
11/05/2025Interior lighting powerERIC BERLENTenergy_progress
11/05/2025Fire-Resistance Rated ConstructionERIC BERLENTprogress
11/05/2025FinalERIC BERLENTprogress
11/05/2025Energy Code Compliance InspectionsERIC BERLENTprogress
11/05/2025Fire-Resistant Penetrations and JointsERIC BERLENTspecial
11/05/2025Lighting controlsERIC BERLENTenergy_progress
11/05/2025Mechanical SystemsVincent Liottaspecial
11/05/2025FinalVincent Liottaprogress
11/05/2025HVAC-R and service water heating equipmentVincent Liottaenergy_progress
11/05/2025HVAC-R and service water piping design and insulationVincent Liottaenergy_progress
11/05/2025Maintenance informationVincent Liottaenergy_progress
11/05/2025HVAC-R and service water heating system controlsVincent Liottaenergy_progress
07/16/2025FinalRichard Wainerprogress
06/01/2022Concrete - Cast-In-PlaceMatthew Wavrospecial
06/01/2022FinalMatthew Wavroprogress
04/21/2022Concrete - Cast-In-PlaceMatthew Wavrospecial
04/21/2022FinalMatthew Wavroprogress
04/05/2022HVAC-R and service water heating system controlsMatthew Wavroenergy_progress
04/05/2022Fire-Resistant Penetrations and JointsMatthew Wavrospecial
04/05/2022Fire-Resistance Rated ConstructionMatthew Wavroprogress
04/05/2022Interior lighting powerMatthew Wavroenergy_progress
04/05/2022Lighting controlsMatthew Wavroenergy_progress
Latest 25 of 61.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
CorePower YogaFitness / RecreationFloor 1
Project M01219995 Alteration · LOC Issued · 05/12/2025
Project M01212731 Alteration · LOC Issued · 05/08/2025
TumiRetailFloor 1
Project M00727608 Alteration · Permit Entire · 07/21/2022
SolidcoreFitness / RecreationFloors 1–5
Project M00737140 Alteration · LOC Issued · 06/19/2022
Project M00737141 Alteration · LOC Issued · 06/19/2022
Project M00667838 Alteration · Permit Entire · 04/11/2022
Project M00667893 Alteration · LOC Issued · 04/06/2022
Project M00667932 Alteration · Permit Entire · 04/06/2022
Project M00668202 Alteration · Permit Entire · 04/05/2022
TargetRetailFloor 1
Project M00032216 Alteration · LOC Issued · 05/02/2018
Project M00032225 Alteration · LOC Issued · 05/02/2018
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 1,014 on file (BIS + DOB NOW)
▸Plans & Drawings35
▸DOB NOWPlans/Sketch24
09/06/2026M00032195-I1Request digital key ↗
09/06/2026M00032208-I1Request digital key ↗
09/06/2026M00032201-I1Request digital key ↗
Showing 3 of 24 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems4
09/04/2026M00392635-I1Request digital key ↗
09/04/2026M00300109-I1Request digital key ↗
08/15/2026M00300109-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler3
09/05/2026M00300011-P1Request digital key ↗
09/05/2026M00300011-I1Request digital key ↗
09/04/2026M00399370-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing3
09/05/2026M00300011-P1Request digital key ↗
09/05/2026M00300011-I1Request digital key ↗
09/04/2026M00399396-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sign1
08/15/2026M00414574-I1Request digital key ↗
▸Applications & Permits158
▸BISPLAN / WORK APPROVAL APPLICATION88
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
03/29/2019123340606Open ↗
Showing 3 of 88 on file for this type
▸BISWORK PERMIT APPLICATION69
09/06/2020140947634Open ↗
01/22/2020140883738Open ↗
08/17/2018123087569Open ↗
Showing 3 of 69 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Zoning, Tax Lot & Property Records5
▸BISZONING DIAGRAM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
05/06/2019121185519Open ↗
▸BISTAX LOT- TENTATIVE LOT NUMBER ISSUED1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISZONING EXHIBIT IV: CERTIFICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications281
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION112
04/08/2019123340606Open ↗
04/08/2019123340606Open ↗
04/08/2019123340606Open ↗
Showing 3 of 112 on file for this type
▸DOB NOWProgress Inspector Seal & Signature34
09/23/2026M00667838-I1Open ↗
09/17/2026M00300109-I1Open ↗
09/17/2026M00300109-I1Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature33
09/06/2026M00032195-I1Open ↗
09/06/2026M00032208-I1Open ↗
09/06/2026M00032201-I1Open ↗
Showing 3 of 33 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT29
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
07/20/2018123484489Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature20
09/23/2026M00300011-I1Open ↗
09/23/2026M00667838-I1Open ↗
09/23/2026M00300011-I1Open ↗
Showing 3 of 20 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST15
03/29/2019123340606Open ↗
07/20/2018123484489Open ↗
Showing 2 of 15 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION14
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
Showing 2 of 14 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY14
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
Showing 2 of 14 on file for this type
▸BISAPPLICANT OWNER SIGNATURE8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Trade Schedules & Equipment36
▸BISSCHEDULE B - PLUMBING14
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 14 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT5
04/26/2018121185519Open ↗
04/26/2018121185519Open ↗
04/26/2018121185519Open ↗
Showing 3 of 5 on file for this type
▸BISGAS CUT-OFF4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA4
11/05/2018123214253Open ↗
08/23/2018122332083Open ↗
Showing 2 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
07/30/2018123340615Open ↗
Showing 1 of 4 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSEWER CUT-OFF2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISEQUIPMENT USE PERMITS1
04/26/2018121185519Open ↗
▸Safety & Tenant Protection28
▸DOB NOWTenant Protection Plan9
09/05/2026M00300011-I1Open ↗
09/05/2026M00300011-P1Open ↗
09/04/2026M00392635-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTENANT PROTECTION PLAN AND NOTES6
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
07/20/2018123484489Open ↗
Showing 3 of 6 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISSTREET TREE CHECKLIST2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
05/06/2019121185519Open ↗
▸BISBPP: STREET TREES SITE PLAN1
10/25/2018140230426Open ↗
▸Environmental & Asbestos8
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
01/15/2020140883738Open ↗
Showing 1 of 6 on file for this type
▸BISRODENT CONTROL2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Energy Compliance38
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS17
04/08/2019123340606Open ↗
04/08/2019123340606Open ↗
12/13/2018140523672Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY9
02/19/2021140883738Open ↗
09/06/2020140947634Open ↗
09/04/2020140947634Open ↗
Showing 3 of 9 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS6
02/19/2021140883738Open ↗
04/08/2019123340606Open ↗
12/13/2018140523672Open ↗
Showing 3 of 6 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
▸Inspections & Test Reports62
▸BISTECHNICAL REPORT: RESPONSIBILITY30
02/19/2021140883738Open ↗
09/06/2020140947634Open ↗
09/04/2020140947634Open ↗
Showing 3 of 30 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER16
04/08/2019123340606Open ↗
04/08/2019123340606Open ↗
06/20/2018122945242Open ↗
Showing 3 of 16 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISTECHNICAL REPORT: SOIL INSPECTION4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISTECHNICAL REPORT: PILE DRIVING3
08/20/2018140314292Open ↗
Showing 1 of 3 on file for this type
▸BISHYDRAULIC FLOW CALCULATIONS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs118
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST54
02/19/2021140883738Open ↗
05/14/2019121185519Open ↗
05/06/2019121185519Open ↗
Showing 3 of 54 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION40
07/20/2018123484489Open ↗
Showing 1 of 40 on file for this type
▸BISCONSTRUCTION CODE DETERMINATION8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISTRANSIT AUTHORITY/MTA/PANYNJ APPROVAL2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Cost, Insurance & Ownership24
▸BISCOST AFFIDAVIT16
02/19/2021140883738Open ↗
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
Showing 3 of 16 on file for this type
▸BISPROJECT-SPECIFIC GL INSURANCE8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸Filing & Intake Forms166
▸BISADDITIONAL INFORMATION61
10/28/2020140883738Open ↗
04/29/2020140883738Open ↗
01/25/2019140230391Open ↗
Showing 3 of 61 on file for this type
▸BISBOROUGH INTAKE FORM52
05/14/2019121185519Open ↗
05/06/2019121185519Open ↗
04/08/2019123340606Open ↗
Showing 3 of 52 on file for this type
▸BISEFILING COVER SHEET30
07/20/2018123484489Open ↗
03/20/2018123214253Open ↗
Showing 2 of 30 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET22
09/04/2020140947634Open ↗
01/15/2020140883738Open ↗
Showing 2 of 22 on file for this type
▸DOB NOWAI1 Form (from plan PDF)1
08/16/2026M00667872-I1Open ↗
▸Other Documents42
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION22
12/13/2018140230391Open ↗
Showing 1 of 22 on file for this type
▸BISSupporting Document: Fee Exempt12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISPLOT DIAGRAM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISBPP-DOT: RELOCATE STREET LIGHT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type