| Owner | Filings | Most Recent |
|---|---|---|
| PLATINUM | 17 | 07/08/2026 |
| JASCO | 4 | 07/08/2026 |
| JANA BUILDERS | 6 | 03/22/2026 |
| BUILDERS CORP JANA | 2 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/26/2024 | $1.8M | — | SMITH ST. 3.477.49, LLC → ADAR CONSULTING PARTNERS LLC | $878/sf building |
| 08/18/2017 | $1.0M | — | 501 SMITH STREET LLC → SMITH ST. 3.477.49, LLC | $518/sf building |
| 05/01/2017 | $1.0M | — | RED HOOK CONCRETE LOADING CORP. → 501 SMITH STREET LLC | $500/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| CHUN ENGINEERING CONSULTANT PLLC | 9 | 05/17/2025 |
| NEW YORK DESIGN ARCHITECTS, LLP | 2 | 02/20/2025 |
| MJE PROFESSIONAL SERVICES | 1 | 10/03/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| SNR EXPEDITING DESIGN | 2 | 03/21/2026 |
| NEW YORK DESIGN ARCHITECT LLP | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| JANA BUILDERS CORP | General Contractor | 8 | 07/08/2026 |
| MG DECORATIONS LTD | General Contractor | 3 | 03/21/2026 |
| JASCO, INC | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| DAL H CHUN ENGINEER PC | 1972 | 8 | 05/17/2025 |
| AKS ARCHITECTURAL & ENGIN | 1957 | 1 | 02/20/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | JANA BUILDERS CORP | 07/10/2025 |
| DOB NOW | Mechanical Systems | Signed-off | MG DECORATIONS LTD | 05/19/2025 |
| DOB NOW | Structural | Signed-off | JANA BUILDERS CORP | 11/01/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | JASCO, INC | 10/04/2024 |
| DOB NOW | Construction Fence | Signed-off | JANA BUILDERS CORP | 09/27/2024 |
| DOB NOW | General Construction | Permit Issued | JANA BUILDERS CORP | 09/18/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/17/2025 | Permit Issued | JANA BUILDERS CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM48NAMHZ 4 tons · Heat Pump Outdoor ×4 Ventilation Panasonic WhisperCeiling 100 CFM · Exhaust Fan ×4 |
| 02/20/2025 | — | — | Heating and Air Conditioning Systems | Heat / Cool Trane TUHYE1443AN41AN 144,000 BTU · Condensing Unit ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/17/2025 | — | — | Gas, Storm, Water/Sanitary |
| 02/20/2025 | — | — | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/12/2025 | Complete | BLZ ELECTRIC INC. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/17/2025 | Permit Issued | JANA BUILDERS CORP | Steel, Masonry |
| Date | Type | Result | Report |
|---|---|---|---|
| 02/25/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 02/23/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 07/22/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/18/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/22/2024 | Pass-Final PL - Underground | Pass | View ↗ |
| 04/16/2024 | Fail-Final PL - Underground | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/30/2025 | Fire-Resistant Penetrations and Joints | DAL CHUN | special |
| 06/30/2025 | Maintenance information | DAL CHUN | energy_progress |
| 06/30/2025 | Air barrier - visual inspection | DAL CHUN | energy_progress |
| 06/30/2025 | Fenestration air leakage | DAL CHUN | energy_progress |
| 06/30/2025 | Exterior lighting power | DAL CHUN | energy_progress |
| 06/30/2025 | Metering | DAL CHUN | energy_progress |
| 06/30/2025 | Permanent certificate | DAL CHUN | energy_progress |
| 06/30/2025 | Interior lighting power | DAL CHUN | energy_progress |
| 06/30/2025 | Lighting controls | DAL CHUN | energy_progress |
| 06/30/2025 | Fenestration areas | DAL CHUN | energy_progress |
| 06/30/2025 | Insulation placement and R values | DAL CHUN | energy_progress |
| 06/30/2025 | Lowest Floor Elevation | DAL CHUN | progress |
| 06/30/2025 | Energy Code Compliance Inspections | DAL CHUN | progress |
| 06/30/2025 | Fire-Resistance Rated Construction | DAL CHUN | progress |
| 06/30/2025 | Preliminary | DAL CHUN | progress |
| 06/30/2025 | Structural Stability – Alterations of existing buildings | DAL CHUN | special |
| 06/30/2025 | Fenestration and door U-factor and product ratings | DAL CHUN | energy_progress |
| 05/19/2025 | Mechanical Systems | DAL CHUN | special |
| 05/19/2025 | Fire-Resistant Penetrations and Joints | DAL CHUN | special |
| 05/19/2025 | Final | DAL CHUN | progress |
| 05/19/2025 | Shutoff dampers | DAL CHUN | energy_progress |
| 05/19/2025 | HVAC-R and service water heating equipment | DAL CHUN | energy_progress |
| 05/19/2025 | HVAC-R and service water piping design and insulation | DAL CHUN | energy_progress |
| 05/19/2025 | HVAC-R and service water heating system controls | DAL CHUN | energy_progress |
| 05/15/2025 | Mechanical Systems | DAL CHUN | special |