| Owner | Filings | Most Recent |
|---|---|---|
| 52 HAVEMEYER | 69 | 09/01/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/21/2021 | $2.8M | — | ABBA'S HOUSE LLC → 52 HAVEMEYER LLC | $733/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| THOMAS BARRY ARCHITECT | 12 | 05/02/2025 |
| CONCORD CONSULTING ENGINEERING PC | 5 | 02/24/2025 |
| CELIN MUNOZ CONSULTING ENGINEER, PC | 4 | 12/05/2024 |
| MSM ENGINEERING SERVICES, PLLC | 2 | 03/07/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| OPERA STUDIO ARCHITECTURE LLC | 8 | 03/21/2026 |
| M W EXPEDITING | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| K.W.MCINTOSH CONSTRUCTION | General Contractor | 8 | 09/01/2026 |
| ANDAMIO SCAFFOLDING LLC | General Contractor | 4 | 07/08/2026 |
| EARLY PLBG & HTG INC | Plumbing | 4 | 07/08/2026 |
| EARLY PLUMBING & HTG INC | Fire Protection | 2 | 07/08/2026 |
| BOROWIDE ELECT'L CONTR'S | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| OPERA STUDIO ARCHITECTURE | 5970 | 9 | 01/29/2025 |
| STEEL CORE ENGINEERING PL | 1098 | 3 | 01/29/2025 |
| TOWER CONSULTING ENGINEER | 7310 | 2 | 12/28/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Permit Issued | K.W.MCINTOSH CONSTRUCTION | 08/31/2026 |
| DOB NOW | Construction Fence | Permit Issued | K.W.MCINTOSH CONSTRUCTION | 09/09/2025 |
| DOB NOW | Boiler Equipment | Signed-off | EARLY PLBG & HTG INC | 02/26/2025 |
| DOB NOW | Plumbing | Permit Issued | EARLY PLBG & HTG INC | 10/17/2024 |
| DOB NOW | Sprinklers | Signed-off | EARLY PLUMBING & HTG INC | 10/02/2024 |
| DOB NOW | Sprinklers | Signed-off | EARLY PLUMBING & HTG INC | 04/02/2024 |
| DOB NOW | Supported Scaffold | Signed-off | ANDAMIO SCAFFOLDING LLC | 03/07/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | ANDAMIO SCAFFOLDING LLC | 03/07/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | K.W.MCINTOSH CONSTRUCTION | 10/19/2023 |
| DOB NOW | Plumbing | Permit Issued | EARLY PLBG & HTG INC | 08/07/2023 |
| DOB NOW | Plumbing | Permit Issued | EARLY PLBG & HTG INC | 10/25/2022 |
| DOB NOW | General Construction | Permit Issued | K.W.MCINTOSH CONSTRUCTION | 10/24/2022 |
| BIS | FP | ISSUED | NEW YORK BUSINESS FIRE SYSTEM IN | 05/03/2007 |
| BIS | PL | ISSUED | CALA/SACCO MECHANICAL, INC. | 02/28/2007 |
| BIS | OT | ISSUED | TJUN INDUSTRIES INC | 02/21/2007 |
| BIS | PL | ISSUED | VITUCCI PLUMB & HTG INC | 11/20/2006 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/02/2025 | Permit Issued | K.W.MCINTOSH CONSTRUCTION | Associated Ducts and Piping, Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric SUZ-KA09NA 36,000 BTU · Split System ×4 PUZ-A36NKA7 36,000 BTU · Split System ×1 SUZ-KA12NA 12,000 BTU · Split System ×1 SUZ-KA15NA 15,000 BTU · Split System ×1 Ventilation N/A ×8 |
| 01/29/2025 | Permit Issued | K.W.MCINTOSH CONSTRUCTION | Air Conditioning Systems | Cooling Mitsubishi Electric SUZ-KA12NAHZ 12,000 BTU · Heat Pump Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/02/2025 | — | — | Sprinkler System |
| 01/29/2025 | Signed-off | EARLY PLUMBING & HTG INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/02/2025 | — | — | Storm, Water/Sanitary |
| 01/29/2025 | Permit Issued | EARLY PLBG & HTG INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/19/2024 | Complete | BOROWIDE ELECT'L CONTR'S | — |
| 01/05/2022 | Permit Issued | URBAN TECH ELECTRIC INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/02/2025 | Permit Issued | K.W.MCINTOSH CONSTRUCTION | Steel, Concrete, Masonry |
| 01/29/2025 | Permit Issued | EARLY PLBG & HTG INC | Steel |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/02/2025 | Permit Issued | K.W.MCINTOSH CONSTRUCTION | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/03/2025 | Pass-Final Boiler Equipment Inspection | Pass | View ↗ |
| 05/08/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 05/08/2024 | Certified Sprinkler - SP - Roughing | Certified | View ↗ |
| 02/01/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 12/04/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 12/04/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/18/2025 | Seismic Isolation Systems | — | special |
| 02/18/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 02/18/2025 | Post-installed Anchors | — | special |
| 02/05/2025 | Seismic Isolation Systems | Alexander Sheyman | special |
| 02/05/2025 | Sprinkler Systems | Alexander Sheyman | special |
| 02/05/2025 | Fire-Resistant Penetrations and Joints | Thomas Barry | special |
| 02/05/2025 | Post-installed Anchors | Alexander Sheyman | special |
| 01/28/2025 | Fire-Resistant Penetrations and Joints | Thomas Barry | special |
| 01/22/2025 | Fire-Resistant Penetrations and Joints | Thomas Barry | special |
| 12/04/2024 | Concrete - Cast-In-Place | — | special |
| 12/04/2024 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 12/03/2024 | Post-installed Anchors | — | special |
| 12/03/2024 | Excavations - Sheeting, Shoring, and Bracing | — | special |
| 12/03/2024 | Subgrade Inspections | — | special |
| 12/03/2024 | Masonry | — | special |
| 12/03/2024 | Structural Cold-Formed Steel | — | special |
| 12/03/2024 | Structural Steel - Details | — | special |
| 12/03/2024 | Structural Steel - High Strength Bolting | — | special |
| 12/03/2024 | Structural Steel - Welding | — | special |
| 12/03/2024 | Concrete - Cast-In-Place | — | special |
| 12/03/2024 | Structural Stability – Alterations of existing buildings | — | special |
| 12/03/2024 | Subgrade Inspections | — | special |
| 12/03/2024 | Subsurface Conditions – Fill Placement & In-Place Density | — | special |
| 12/03/2024 | Underpinning | — | special |
| 11/14/2024 | Sprinkler Systems | — | special |