← Back
Church, synagogue, chapel
One Bennett Park
524 FORT WASHINGTON AVENUE · Washington Heights (North) · BIN 1076762
💬 Discuss this project
1959Year Built
6Stories
M1Building Class
R7-2Zoning
330,234 sfGross Floor Area
2Units
18 Open Violations 16 unresolved · 2 paperwork only ▸
Church, synagogue, chapel · Owner of record: BENNETT PROPERTY OWNER LLC · 45,971 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionCivilGeneralOther
Permit Issued — active, not yet Signed-off
Site & exteriorUnder Construction6p · 2 filings · 4 docs
Filed — no permit issued393p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BENNETT PROPERTY OWNER3708/21/2026
FORT TRYON TOWERS2703/21/2026
OWNERS REP908/04/2026
FORT TRYON TOWER SPE303/21/2026
THOMPSON DEVELOPMENT GROUP303/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/28/2022$6.0M—— → —$242/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES1003/21/2026
EXPEDITE DEM603/21/2026
AE DESIGN SOLUTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FOUNDATIONS INTERIOR DESIGNGeneral Contractor908/21/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor808/04/2026
CAPIZZO, VITOElectrical103/21/2026
CARL KIMMELElectrical103/21/2026
EDGAR LEVENSTEINElectrical103/21/2026
ALLEN, RICHARDElectrical103/21/2026
KING, ARTHURElectrical103/21/2026
PIMPINELLA, FRANKElectrical103/21/2026
V. VASS ELECTRIC CORPElectrical103/22/2026
FAJARDO, JOSEElectrical103/21/2026
BONNETT, BILLYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STROH ENGINEERING SERVICE3316105/30/2023
RA ENGINEERING LLP6986110/25/2022
Building Lifecycle
All (187)Filed (14)Permit Issued (14)Violation (60)Objection (69)Special Inspection (30)
08/20/2026
Permit issued — Construction Fence
M08022728-I1-FN
08/10/2026
Violation issued (ECB, open)
Construction
08/03/2026
Permit issued — Sidewalk Shed
M00727544-I1-SH
05/27/2026
Permit issued — Construction Fence
M08022728-I1-FN
05/06/2026
Permit issued — Sidewalk Shed
M00727544-I1-SH
04/02/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/31/2026
Objection raised — Other
03/31/2026
Objection resolved — Addressed
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/05/2025
Special inspection requirement — Energy Code Compliance Inspections
09/26/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/28/2025
Permit issued — Construction Fence
M08022728-I1-FN
05/05/2025
Permit issued — Sidewalk Shed
M00727544-I1-SH
03/21/2025
Permit issued — Construction Fence
M08022728-I1-FN
12/10/2024
Violation issued (ECB, closed)
Construction
10/24/2024
Permit issued — Construction Fence
M08022728-I1-FN
10/21/2024
Objection resolved — Resolved
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/14/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
NIDAL ABISAAB
07/29/2024
Objection raised — Other
07/29/2024
Objection resolved — Addressed
06/04/2024
Permit issued — Construction Fence
M08022728-I1-FN
05/07/2024
Permit issued — Sidewalk Shed
M00727544-I1-SH
02/21/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/06/2024
Filed — Full Demolition
full demolition of existing building consisting of 3 levels above grad, and three levels below grade.
M00868056-S2
01/19/2024
Objection raised — Other
01/19/2024
Objection resolved — Addressed
12/30/2023
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
12/30/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
12/30/2023
Special inspection requirement — Luminous Exit Path Markings
12/11/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/11/2023
Violation issued (ECB, closed)
Construction
12/05/2023
Special inspection requirement — Metering
12/05/2023
Special inspection requirement — Lighting in dwelling units
12/05/2023
Special inspection requirement — Interior lighting power
12/05/2023
Special inspection requirement — Exterior lighting power
12/05/2023
Special inspection requirement — Electrical motors and elevators
12/05/2023
Special inspection requirement — Lighting controls
09/13/2023
Objection raised — Other
09/13/2023
Objection resolved — Addressed
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/06/2023
Permit issued — Construction Fence
M08022728-I1-FN
06/06/2023
Objection raised — Admin
06/06/2023
Objection raised — Other
06/06/2023
Objection raised — Inspections
06/06/2023
Objection raised — Fire_Protection
06/06/2023
Objection raised — Scope
06/06/2023
Objection raised — Structural
06/06/2023
Objection raised — Structural
06/06/2023
Objection raised — Inspections
06/06/2023
Objection raised — Admin
06/06/2023
Objection raised — Scope
06/06/2023
Objection raised — Other
06/05/2023
Objection raised — C-26
06/05/2023
Objection resolved — Addressed
06/05/2023
Objection raised — Other
06/05/2023
Objection resolved — Addressed
Latest 60 of 187 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESIGN08/20/2026
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC.08/03/2026
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESIGN05/27/2026
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC.05/06/2026
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESI05/28/2025
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC05/05/2025
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESI03/21/2025
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESI10/24/2024
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESI06/04/2024
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC05/07/2024
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESI06/06/2023
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC05/11/2023
DOB NOWConstruction FencePermit IssuedFOUNDATIONS INTERIOR DESI03/01/2023
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC05/13/2022
BISEQISSUEDFOUNDATIONS GROUP I, INC08/10/2017
BIS—ISSUEDFOUNDATIONS GROUP I, INC08/10/2017
BISEQISSUEDFOUNDATIONS GROUP I, INC11/17/2016
BIS—ISSUEDFOUNDATIONS GROUP I, INC11/17/2016
BIS—ISSUEDTHE J CONSTRUCTION CO LLC08/19/2016
BISEQISSUEDTHE J CONSTRUCTION CO LLC08/19/2016
BIS—ISSUEDFOUNDATIONS GROUP I, INC08/12/2016
BISEQISSUEDFOUNDATIONS GROUP I, INC08/12/2016
BIS—ISSUEDTHE J CONSTRUCTION CO LLC08/19/2015
BIS—ISSUEDTHE J CONSTRUCTION CO LLC08/18/2015
BISEQISSUEDTHE J CONSTRUCTION CO LLC08/18/2015
BIS—ISSUEDTHE J CONSTRUCTION CO LLC10/31/2014
BISEQISSUEDTHE J CONSTRUCTION CO LLC10/31/2014
BISEQISSUEDTHE J CONSTRUCTION CO LLC10/31/2014
BIS—ISSUEDTHE J CONSTRUCTION CO LLC10/31/2014
BIS—ISSUEDSHAWMUT WOODWORKING & SUPPLY12/31/2013
BISEQISSUEDSHAWMUT WOODWORKING & SUPPLY11/21/2012
BIS—ISSUEDSHAWMUT WOODWORKING & SUPPLY11/21/2012
BIS—ISSUEDSHAWMUT WOODWORKING & SUPPLY11/07/2012
BISEQISSUEDSHAWMUT WOODWORKING & SUPPLY11/07/2012
BISEQISSUEDSHAWMUT WOODWORKING & SUPPLY03/19/2012
BIS—ISSUEDSHAWMUT WOODWORKING & SUPPLY03/19/2012
BISEQISSUEDSHAWMUT WOODWORKING & SUPPLY03/13/2012
BIS—ISSUEDSHAWMUT WOODWORKING & SUPPLY03/13/2012
BISEQISSUEDTHE MANHATTAN COMPANY OF*01/06/2012
BIS—ISSUEDTHE MANHATTAN COMPANY OF*10/05/2011
+ 24 more permits on file
1 project · most recent 05/23/2023
Associated Ducts and Piping Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/23/2023——Associated Ducts and Piping, Heating and Air Conditioning Systems
Heat / Cool
Daikin REYQ144AAYDA 12 tons · Vrf Outdoor ×27
4MXS36RMVJUA 3 tons · Split System ×1
RX36NMVJUA 3 tons · Heat Pump Outdoor ×1
RXYQ96XAYDA 8 tons · Vrf Outdoor ×1
Ducts & Piping
Daikin FXMQ09PBVJU 9,500 BTU · Vrf Indoor ×181
FXMQ12PBVJU 12,000 BTU · Vrf Indoor ×96
FXMQ07PBVJU 7,200 BTU · Vrf Indoor ×49
FXMQ18PBVJU 18,000 BTU · Vrf Indoor ×32
FXAQ18PVJU 18,000 BTU · Vrf Indoor ×4
FXMQ24PBVJU 24,000 BTU · Vrf Indoor ×4
FXMQ48PBVJU 48,000 BTU · Vrf Indoor ×4
FTSX18LVJU 18,000 BTU · Split System ×2
FXMQ36PBVJU 36,000 BTU · Vrf Indoor ×2
FXMQ48PVBJU 48,000 BTU · Vrf Indoor ×2
FXTQ48PBVJU 48,000 BTU · Vrf Indoor ×2
FTX36NVJU 36,000 BTU · Fan Coil Indoor ×1
3 projects · most recent 11/02/2025
FiledStatusContractorScope
11/02/2025Permit IssuedAPN ELECTRICAL CORP—
02/07/2023Permit IssuedCONTACT PLUS ELEC'L CORP—
04/22/2022Permit IssuedV. VASS ELECTRIC CORP—
1 project · most recent 05/23/2023
Concrete
FiledStatusContractorScope
05/23/2023——Concrete
2 projects · most recent 01/24/2023
Fence Sidewalk Shed
FiledStatusContractorScope
01/24/2023Permit IssuedFOUNDATIONS INTERIOR DESIFence
05/02/2022Permit IssuedCORE SCAFFOLD SYSTEMS INCSidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
11/05/2025Energy Code Compliance Inspections—progress
08/14/2024Subsurface Investigations (Borings/Test Pits)NIDAL ABISAABspecial
12/30/2023Wall Panels, Curtain Walls, and Veneers—special
12/30/2023Exterior Insulation and Finish Systems (EIFS)—special
12/30/2023Luminous Exit Path Markings—special
12/05/2023Metering—energy_progress
12/05/2023Lighting in dwelling units—energy_progress
12/05/2023Interior lighting power—energy_progress
12/05/2023Exterior lighting power—energy_progress
12/05/2023Electrical motors and elevators—energy_progress
12/05/2023Lighting controls—energy_progress
05/24/2023Structural Stability – Alterations of existing BuildingsPETER STROHspecial
05/24/2023DemolitionPETER STROHspecial
04/20/2023Fire-Resistant Penetrations and Joints—special
04/18/2023HVAC-R and service water piping design and insulation—energy_progress
04/18/2023Maintenance information—energy_progress
04/18/2023HVAC-R and service water heating system controls—energy_progress
04/18/2023HVAC-R and service water heating equipment—energy_progress
04/06/2023Air barrier continuity plan testing—energy_progress
04/06/2023Maintenance information—energy_progress
04/06/2023Air barrier - visual inspection—energy_progress
12/21/2022Sprinkler Systems—special
12/21/2022Standpipe Systems—special
10/25/2022Post-installed Anchors—special
10/21/2022Post-installed Anchors—special
Latest 25 of 44.
▾Documents — 103 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
09/02/2026M00727544-I1Request digital key ↗
08/28/2026M00868056-S1Request digital key ↗
08/28/2026M00868056-S2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits25
▸BISWORK PERMIT APPLICATION15
08/21/2017104126447Open ↗
12/13/2016120942454Open ↗
09/01/2016120942454Open ↗
Showing 3 of 15 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION9
06/08/2023141022042Open ↗
09/22/2021104126447Open ↗
01/11/2012120942454Open ↗
Showing 3 of 9 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation1
06/08/2023141022042Open ↗
▸Zoning, Tax Lot & Property Records5
▸BISTAX LOT- TENTATIVE LOT NUMBER ISSUED2
11/05/2011120857340Open ↗
10/11/2011120857340Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026M00775662-I1Open ↗
▸DOB NOWRestrictive Declaration/Easement 11
08/13/2026M00775662-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026M00775662-I1Open ↗
▸Seals & Professional Certifications30
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/28/2026M00868056-S2Open ↗
08/28/2026M00868056-S1Open ↗
08/28/2026M00868056-I1Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
03/19/2008110094754Open ↗
03/05/2008110094754Open ↗
11/07/2007110012860Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
01/11/2012120942454Open ↗
10/11/2011120857340Open ↗
02/06/2008110082240Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
01/11/2012120942454Open ↗
10/11/2011120857340Open ↗
02/06/2008110082240Open ↗
Showing 3 of 4 on file for this type
▸BISPC FULL REPORT1
11/07/2007110012860Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
06/08/2023141022042Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/08/2023141022042Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
06/19/2008110207972Open ↗
▸Safety & Tenant Protection3
▸BISBPP: STREET TREES SITE PLAN1
06/08/2023141022042Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026M00775662-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026M00775662-I1Open ↗
▸Environmental & Asbestos7
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER5
06/19/2008110207972Open ↗
04/07/2008110129030Open ↗
03/05/2008110094754Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS-EXEMPTION (ASB4)2
01/11/2012120942454Open ↗
10/11/2011120857340Open ↗
▸Inspections & Test Reports2
▸DOB NOWSoil Report2
08/13/2026M00775662-S6Open ↗
08/13/2026M00775662-S1Open ↗
▸Approvals, Objections & Sign-offs13
▸BISADMINISTRATIVE OBJECTIONS8
01/11/2012120942454Open ↗
06/19/2008110207972Open ↗
04/07/2008110129030Open ↗
Showing 3 of 8 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
08/21/2017104126447Open ↗
08/21/2017104126447Open ↗
11/06/2014120942454Open ↗
Showing 3 of 4 on file for this type
▸BISSUPERSEDING LETTER1
12/13/2016120942454Open ↗
▸Cost, Insurance & Ownership1
▸BISPROJECT-SPECIFIC GL INSURANCE1
08/21/2017104126447Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET4
01/11/2012120942454Open ↗
10/11/2011120857340Open ↗
06/19/2008110207972Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
06/08/2023141022042Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
06/08/2023141022042Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification2
08/15/2026M00868056-I1Open ↗
08/13/2026M00775662-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026M00868056-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026M00775662-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026M00775662-I1Open ↗