← Back
Professional building / stand-alone funeral home
60 BRIGHTON 11 STREET
BROOKLYN · Brighton Beach · BIN 3245363
💬 Discuss this project
1931Year Built
2Stories
O7Building Class
C8-1Zoning
5,720 sfGross Floor Area
1Units
3 Open Violations 0 unresolved · 3 paperwork only ▸FDNY Report ↗
Professional building / stand-alone funeral home · Owner of record: 60 BRIGHTON 11, LLC · 7,550 sf lot · 0.76 FAR built · Flood zone X500
Locations of Work
MechanicalPlumbing
Floor 13p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
60 BRIGHTON 11, LLC203/22/2026
60 BRIGHTON II, L.L.C103/22/2026
KEHILA CHAPLES INC203/22/2026
KEHILA CHAPELS503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HANSEN ENGINEERING, PC105/03/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GRAND EXPEDITERS NYC103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HANSEN ENGINEERING PC8174105/03/2022
Building Lifecycle
All (43)Filed (1)Violation (23)Objection (13)Special Inspection (6)
05/10/2022
Objection raised — Admin
05/10/2022
Objection raised — Structural
05/10/2022
Objection resolved — Addressed
05/10/2022
Objection raised — Fire_Protection
05/10/2022
Objection raised — Accessibility
05/10/2022
Objection raised — Scope
05/10/2022
Objection raised — Mechanical
05/10/2022
Objection resolved — Addressed
05/10/2022
Objection raised — Fire_Protection
05/10/2022
Objection resolved — Addressed
05/10/2022
Objection raised — Fire_Protection
05/10/2022
Objection raised — Fire_Protection
05/10/2022
Objection resolved — Addressed
05/03/2022
Filed — Alteration
B00693079-I1
03/31/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ryan Hansen
03/31/2022
Special inspection requirement — Heating Systems
Ryan Hansen
03/31/2022
Special inspection requirement — Maintenance information
Ryan Hansen
03/31/2022
Special inspection requirement — HVAC-R and service water heating system controls
Ryan Hansen
03/31/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Ryan Hansen
03/31/2022
Special inspection requirement — HVAC-R and service water heating equipment
Ryan Hansen
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/15/2020
Violation issued (ECB, open)
Boilers
01/15/2020
Violation issued (ECB, open)
Construction
01/06/2020
Violation issued (ECB, open)
Construction
09/19/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/10/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/20/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/25/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/27/2002
Violation issued (ECB, closed)
Construction
08/22/2002
Violation issued (ECB, closed)
Construction
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/10/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/18/1989
Violation issued (ECB, closed)
Public Assembly
05/18/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/18/1989
Violation issued (ECB, closed)
Public Assembly
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDSTARLITE PLBG & HTG CORP09/04/1998
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/31/2022Fire-Resistant Penetrations and JointsRyan Hansenspecial
03/31/2022Heating SystemsRyan Hansenspecial
03/31/2022Maintenance informationRyan Hansenenergy_progress
03/31/2022HVAC-R and service water heating system controlsRyan Hansenenergy_progress
03/31/2022HVAC-R and service water piping design and insulationRyan Hansenenergy_progress
03/31/2022HVAC-R and service water heating equipmentRyan Hansenenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/14/2026B00693079-I1Request digital key ↗
▸Applications & Permits3
▸BISPLACE OF ASSEMBLY3
10/06/2015301442124Open ↗
05/01/2015301442124Open ↗
04/30/2015301442124Open ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B00693079-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B00693079-I1Open ↗