| Owner | Filings | Most Recent |
|---|---|---|
| NYC School Construction Authority | 36 | 10/06/2026 |
| NYC Department of Education | 8 | 03/22/2026 |
| Doe Division of School Facilities | 2 | 03/21/2026 |
| National Grid | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Joseph Pawell | 2 | 10/05/2026 |
| Anne Marie Edden | 1 | 10/05/2026 |
| Lilker Associates Consulting Engineering | 6 | 10/08/2024 |
| Cta Architects | 2 | 10/07/2024 |
| Afridi Associates | 2 | 10/07/2024 |
| NYC School Construction Authority | 4 | 05/02/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| NYC School Construction Authority | 4 | 03/21/2026 |
| Municipal Building Consultants | 10 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| A & S Electric | Electrical | 8 | 03/21/2026 |
| Charan Electrical Enterp's | Electrical | 1 | 03/22/2026 |
| Gemini Electric Co | Electrical | 1 | 03/22/2026 |
| Jeco Electrical Service | Electrical | 1 | 03/21/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | MH | ISSUED | Volmar Construction | 06/30/2020 |
| BIS | OT | ISSUED | S&S Kings | 09/26/2019 |
| BIS | OT | ISSUED | S&S Kings | 08/28/2018 |
| BIS | OT | ISSUED | S&P Construction Management | 06/04/2008 |
| BIS | PL | ISSUED | Forsythe P&H | 06/21/2007 |
| BIS | EQ | ISSUED | Spring Scaffolding | 01/17/2001 |
| BIS | PL | ISSUED | A Berwind Plumbing & Heating Co | 08/11/2000 |
| BIS | OT | ISSUED | Phoenix Services | 08/02/2000 |
| BIS | EQ | ISSUED | Spring Scaffolding | 07/18/2000 |
| BIS | EQ | ISSUED | Phoenix Services | 07/17/2000 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/08/2024 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | |
| 05/02/2024 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PKA-A24KA7 24,000 BTU · Fan Coil Indoor ×2 PUY-A24NHA7 24,000 BTU · Split System ×2 Ventilation Greenheck GB-160 3,500 CFM · Exhaust Fan ×10 FGR-8X8 8,000 CFM ×8 GB-100 750 CFM · Exhaust Fan ×4 GB-120 1,250 CFM · Exhaust Fan ×4 FGR-20X30 6,000 CFM ×2 FGR-30X40 12,000 CFM ×2 G-130-A 2,000 CFM · Exhaust Fan ×2 G-130A 2,000 CFM · Exhaust Fan ×2 GB- 160 3,000 CFM · Exhaust Fan ×2 Gb-160 3,500 CFM · Exhaust Fan ×2 |
| 12/18/2023 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric TPKA0A0121LA00A 12,000 BTU · Fan Coil Indoor ×1 TPKA0A0361KA70A 36,000 BTU · Split System ×1 TRUZA0121KA70NA 12,000 BTU · Vrf Outdoor ×1 TRUZA0361KA70NA 36,000 BTU · Split System ×1 Ventilation Greenheck CSP-A390-VG 150 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/18/2023 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2024 | — | — | Gas |
| 05/02/2024 | — | — | Storm |
| 12/18/2023 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/14/2026 | Complete | H. & L. Electric | General Wiring |
| 06/15/2026 | Complete | Charan Electrical Enterp's | — |
| 11/25/2024 | Complete | Everest Electric | — |
| 07/09/2024 | Complete | MNBC Electrical | General Wiring |
| 09/25/2023 | Complete | Charan Electrical Enterp's | — |
| 01/15/2023 | Complete | Gemini Electric Co | — |
| 03/09/2022 | Complete | Charan Electrical Enterp's | — |
| 08/20/2020 | Complete | Charan Electrical Enterp's | — |
| 09/13/2019 | Complete | Charan Electrical Enterp's | General Wiring |
| 08/19/2019 | Permit Issued | BZ Electric | HVAC Wiring |
| 04/11/2019 | Permit Issued | A & S Electric | General Wiring |
| 08/11/2018 | Complete | Jamcob Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/02/2024 | — | — | Concrete, Masonry |
| 12/18/2023 | — | — | Concrete |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/02/2026 | Sprinkler Systems | — | special |
| 10/02/2026 | Excavations - Sheeting, Shoring, and Bracing | — | special |
| 10/02/2026 | Subsurface Conditions – Fill Placement & In-Place Density | — | special |
| 10/02/2026 | Final | — | progress |
| 10/02/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 10/02/2026 | Post-installed Anchors | — | special |
| 10/02/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 10/04/2024 | Fire-Resistant Penetrations and Joints | — | special |
| 10/04/2024 | Fire-Resistant Penetrations and Joints | — | special |
| 10/04/2024 | Maintenance information | — | energy_progress |
| 10/04/2024 | Interior lighting power | — | energy_progress |
| 10/04/2024 | Lighting controls | — | energy_progress |
| 10/04/2024 | Energy Code Compliance Inspections | — | progress |
| 10/01/2024 | Structural Stability – Alterations of existing buildings | — | special |
| 10/01/2024 | Post-installed Anchors | — | special |
| 10/01/2024 | Structural Steel - Welding | — | special |
| 10/01/2024 | Final | — | progress |
| 10/01/2024 | Structural Steel - High Strength Bolting | — | special |
| 10/01/2024 | Structural Steel - Details | — | special |
| 05/01/2024 | Fire-Resistant Penetrations and Joints | — | special |
| 04/30/2024 | Air barrier - visual inspection | — | energy_progress |
| 04/30/2024 | Insulation placement and R values | — | energy_progress |
| 04/30/2024 | Fenestration air leakage | — | energy_progress |
| 04/30/2024 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 04/30/2024 | Fire-Resistant Penetrations and Joints | — | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| P.S. 257 John F. Hylan | Education | Entire building | Project B01468969 Project B01120407 Project B00956644 Project B00969095 |