← Back
BuildNYC
Two family brick
61-41 LINDEN STREET
QUEENS · Ridgewood · BIN 4087533
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R5BZoning
3,444 sfGross Floor Area
2Units
6 Active Violations 5 unresolved · 1 paperwork only 1 old, status unconfirmed ▸
Two family brick · Owner of record: 6141 Linden Properties · 2,000 sf lot · 1.72 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 225p · 2 filings · 20 docs
Floor 121p · 2 filings · 20 docs
Cellar20p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Kingston1107/08/2026
25 Crescent Property403/21/2026
55 St Maspeth203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/09/2022$866K—6141 LINDEN FUNDING LLC → 6141 LINDEN PROPERTIES LLC$251/sf building
05/21/2020$899K—6141 LINDEN CORP. → 6141 LINDEN FUNDING, LLC$261/sf building
03/31/2017$640K—ROGERS CAPITAL CORP. → B&H CAPITAL GROUP LLC$186/sf building
06/29/2015$480K—Private party → 6141 LINDEN CORP$139/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Flushing711/17/2025
St Design & Consulting102/09/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
K A Interior Design803/21/2026
R H Drummond Exp203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CYC General ContractingGeneral Contractor303/21/2026
KJK ElectricElectrical203/22/2026
T.N.T. Plumbing & HeatingPlumbing207/08/2026
Kle ConstructionGeneral Contractor107/08/2026
Peter Miceli PlumbingPlumbing109/16/2016
Top Design InteriorsGeneral Contractor107/01/2016
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Flushing Engineering Service4373711/17/2025
2 by 4 Architecture4737306/25/2023
Building Lifecycle
12/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
12/09/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
KY FU
12/09/2025
Special inspection requirement — HVAC-R and service water heating system controls
KY FU
12/09/2025
Special inspection requirement — HVAC-R and service water heating equipment
KY FU
12/09/2025
Special inspection requirement — Energy Code Compliance Inspections
KY FU
73 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT.N.T. Plumbing & Heating11/15/2024
DOB NOWGeneral ConstructionSigned-offKle Construction02/20/2024
DOB NOWPlumbingSigned-offT.N.T. Plumbing & Heating08/09/2023
DOB NOWGeneral ConstructionSigned-offCYC General Contracting05/02/2023
BISPLISSUEDPeter Miceli Plumbing09/16/2016
BISOTISSUEDTop Design Interiors07/01/2016
1 project · most recent 11/17/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/17/2025Signed-offT.N.T. Plumbing & HeatingGas, Water/Sanitary
2 projects · most recent 01/31/2023
General Wiring
FiledStatusContractorScope
01/31/2023Permit IssuedKJK ElectricGeneral Wiring
01/04/2023CompleteKJK Electric—
1 project · most recent 02/09/2023
FiledStatusContractorScope
02/09/2023———
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/14/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/07/2024Pass-Final General Construction Non-Directive 14PassView ↗
10/09/2024Fail-Final General Construction Non-Directive 14FailView ↗
04/18/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/15/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
12/09/2025Fire-Resistant Penetrations and JointsKY FUspecial
12/09/2025HVAC-R and service water piping design and insulationKY FUenergy_progress
12/09/2025HVAC-R and service water heating system controlsKY FUenergy_progress
12/09/2025HVAC-R and service water heating equipmentKY FUenergy_progress
12/09/2025Energy Code Compliance InspectionsKY FUprogress
10/27/2025HVAC-R and service water piping design and insulationKY FUenergy_progress
10/27/2025Fire-Resistant Penetrations and JointsKY FUspecial
10/27/2025Energy Code Compliance InspectionsKY FUprogress
10/27/2025HVAC-R and service water heating system controlsKY FUenergy_progress
10/27/2025HVAC-R and service water heating equipmentKY FUenergy_progress
03/06/2025HVAC-R and service water heating system controlsKY FUenergy_progress
03/06/2025HVAC-R and service water piping design and insulationKY FUenergy_progress
03/06/2025Fire-Resistant Penetrations and JointsKY FUspecial
03/06/2025Energy Code Compliance InspectionsKY FUprogress
03/06/2025HVAC-R and service water heating equipmentKY FUenergy_progress
03/26/2024HVAC-R and service water piping design and insulationKY FUenergy_progress
03/26/2024HVAC-R and service water heating system controlsKY FUenergy_progress
03/26/2024Fire-Resistant Penetrations and JointsKY FUspecial
03/26/2024Energy Code Compliance InspectionsKY FUprogress
03/26/2024HVAC-R and service water heating equipmentKY FUenergy_progress
07/05/2023Fenestration areasCHI WANG LEEenergy_progress
07/05/2023Lighting in dwelling unitsCHI WANG LEEenergy_progress
07/05/2023Air barrier - visual inspectionCHI WANG LEEenergy_progress
07/05/2023Insulation placement and R valuesCHI WANG LEEenergy_progress
07/05/2023Fire-Resistance Rated ConstructionCHI WANG LEEprogress
Latest 25 of 34.
77 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account