← Back
Over six families without stores
619 GLENMORE AVENUE
BROOKLYN · East New York (North) · BIN 3088574
💬 Discuss this project
1930Year Built
4Stories
C1Building Class
R5BZoning
16,175 sfGross Floor Area
15Units
Rent Stabilized68 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: CYPRESS COURT ASSOCIATES L P · 5,000 sf lot · 3.24 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof6p · 1 filing · 16 docs
Cellar8p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINGS GROUP NY909/22/2026
CYPRESS COURT ASSOCIATES LP503/22/2026
PITKIN-BERRIMAN HDFC503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LORING CONSULTING ENGINEERS, INC.303/04/2025
OLD STRUCTURES ENGINEERING112/10/2024
ESKW/A111/06/2024
MOHAMMAD AHEAD, PE102/23/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BETRO DESIGN GROUP503/21/2026
ARSENAL BUILDING CONSULTANTS LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KINGS GROUP NY CORPGeneral Contractor709/22/2026
HIGH QUALITY ELECTRIC OFElectrical103/22/2026
Building Lifecycle
All (141)Filed (6)Permit Issued (5)Violation (60)Objection (44)Special Inspection (26)
09/21/2026
Permit issued — Sidewalk Shed
B01009058-I1-SH
07/22/2026
Violation issued (HPD, open)
A
06/23/2026
Permit issued — Sidewalk Shed
B01009058-I1-SH
05/04/2026
Violation issued (HPD, closed)
A
04/01/2026
Objection resolved — Addressed
03/19/2026
Permit issued — Sidewalk Shed
B01009058-I1-SH
01/20/2026
Objection resolved — Addressed
12/08/2025
Violation issued (ECB, open)
Construction
09/27/2025
Violation issued (HPD, open)
B
09/27/2025
Violation issued (HPD, open)
B
09/27/2025
Violation issued (HPD, open)
B
09/27/2025
Violation issued (HPD, open)
B
09/27/2025
Violation issued (HPD, open)
B
09/18/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/18/2025
Objection resolved — Addressed
07/17/2025
Objection raised — Other
07/17/2025
Objection resolved — Addressed
07/13/2025
Violation issued (HPD, closed)
C
07/13/2025
Violation issued (HPD, closed)
B
07/13/2025
Violation issued (HPD, open)
A
07/13/2025
Violation issued (HPD, open)
B
07/13/2025
Violation issued (HPD, closed)
C
07/13/2025
Violation issued (HPD, open)
A
07/13/2025
Violation issued (HPD, open)
B
07/13/2025
Violation issued (HPD, closed)
C
07/13/2025
Violation issued (HPD, closed)
C
07/13/2025
Violation issued (HPD, open)
B
07/13/2025
Violation issued (HPD, open)
B
06/13/2025
Objection raised — Cost
06/09/2025
Violation issued (HPD, closed)
A
05/30/2025
Objection resolved — Addressed
05/30/2025
Objection resolved — Addressed
05/30/2025
Objection resolved — Addressed
05/30/2025
Objection resolved — Addressed
04/24/2025
Objection resolved — Resolved
04/11/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
04/11/2025
Special inspection requirement — HVAC-R and service water heating system controls
03/28/2025
Objection resolved — Addressed
03/28/2025
Objection resolved — Addressed
03/20/2025
Special inspection requirement — Post-installed Anchors
03/13/2025
Violation issued (HPD, open)
C
03/09/2025
Permit issued — Sidewalk Shed
B01009058-I1-SH
03/06/2025
Objection raised — Scope
03/06/2025
Objection raised — Plumbing
03/04/2025
Filed — Alteration
Facade repairs, roof replacement, window replacement, partial joist replacement, selected door replacement, repairs to existing parapet walls with new terra cotta coping and minor interior repairs as per plans filed. No change in use, egress or occupancy.
B01124944-S2
02/04/2025
Objection raised — Plumbing
02/04/2025
Objection raised — Plumbing
02/04/2025
Objection raised — Plumbing
02/04/2025
Objection raised — Plumbing
01/30/2025
Filed — Alteration
Facade repairs, roof replacement, window replacement, partial joist replacement, selected door replacement, repairs to existing parapet walls with new terra cotta coping and minor interior repairs as per plans filed. No change in use, egress or occupancy.
B01124944-S3
01/17/2025
Objection raised — Admin
01/17/2025
Objection resolved — Addressed
01/17/2025
Objection raised — Structural
01/17/2025
Objection resolved — Addressed
01/17/2025
Objection raised — Scope
01/17/2025
Objection resolved — Addressed
01/17/2025
Objection raised — Scope
01/17/2025
Objection resolved — Addressed
01/16/2025
Filed — Alteration
INSTALL THREE NEW BOILERS, PUMPS, FLUES AND ASSOCIATED PIPING AND EQUIPMENT AND REMOVE TWO EXISTING BOILERS AS PER PLANS FILED.
B01165603-I1
01/16/2025
Objection raised — Structural
Latest 60 of 141 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedKINGS GROUP NY CORP09/21/2026
DOB NOWSidewalk ShedPermit IssuedKINGS GROUP NY CORP06/23/2026
DOB NOWSidewalk ShedPermit IssuedKINGS GROUP NY CORP03/19/2026
DOB NOWSidewalk ShedPermit IssuedKINGS GROUP NY CORP03/09/2025
DOB NOWSidewalk ShedPermit IssuedKINGS GROUP NY CORP03/15/2024
BISPLISSUEDSTEVE PLUMBING09/11/1996
BIS—RE-ISSUEDM & S CONSTRUCTION AND GENERAL04/06/1994
BIS—ISSUEDSEVILLE CONSTR CO INC08/31/1993
1 project · most recent 03/04/2025
Gas Water/Sanitary
FiledStatusContractorScope
03/04/2025——Gas, Water/Sanitary
1 project · most recent 03/08/2024
FiledStatusContractorScope
03/08/2024Permit IssuedHIGH QUALITY ELECTRIC OF—
1 project · most recent 03/04/2025
Masonry Wood
FiledStatusContractorScope
03/04/2025——Masonry, Wood
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
09/18/2025Structural Stability – Alterations of existing buildings—special
04/11/2025HVAC-R and service water piping design and insulation—energy_progress
04/11/2025HVAC-R and service water heating system controls—energy_progress
03/20/2025Post-installed Anchors—special
12/17/2024HVAC-R and service water heating equipment—energy_progress
12/17/2024HVAC-R and service water heating system controls—energy_progress
12/17/2024Final—progress
12/17/2024Shutoff dampers—energy_progress
12/17/2024Tenant Protection Plan Compliance—special
12/17/2024Maintenance information—energy_progress
12/17/2024Mechanical Systems—special
12/17/2024Energy Code Compliance Inspections—progress
12/17/2024Tenant Protection Plan Compliance—special
12/17/2024Heating Systems—special
12/17/2024HVAC-R and service water piping design and insulation—energy_progress
11/06/2024Tenant Protection Plan Compliance—special
11/06/2024Masonry—special
11/06/2024Final—progress
10/09/2024Fire-Resistant Penetrations and Joints—special
10/09/2024Fenestration and door U-factor and product ratings—energy_progress
10/09/2024Lighting controls—energy_progress
10/09/2024Fenestration air leakage—energy_progress
10/09/2024Insulation placement and R values—energy_progress
10/09/2024Energy Code Compliance Inspections—progress
10/09/2024Final—progress
Latest 25 of 26.
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/25/2026B01009058-I1Request digital key ↗
08/23/2026B01124944-S2Request digital key ↗
08/23/2026B01124944-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/25/2026B01009058-I1Open ↗
08/23/2026B01165603-I1Open ↗
08/13/2026B01124944-S3Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/23/2026B01124944-S2Open ↗
08/23/2026B01165603-I1Open ↗
08/13/2026B01124944-S1Open ↗
Showing 3 of 5 on file for this type
▸Approvals, Objections & Sign-offs4
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter4
08/13/2026B01165603-I1Open ↗
08/13/2026B01124944-S2Open ↗
08/13/2026B01124944-S1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents1
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01124944-I1Open ↗