← Back
Home for indigent children, aged, homeless
67-35 112 STREET
QUEENS · Forest Hills · BIN 4441126
💬 Discuss this project
1940Year Built
2Stories
N2Building Class
R4Zoning
32,450 sfGross Floor Area
0Units
0 Open ViolationsFDNY Report ↗
Home for indigent children, aged, homeless · Owner of record: FORESTDALE INC · 142,793 sf lot · 0.23 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 15p · 3 filings · 20 docs
Cellar3p · 2 filings · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FORESTDALE1303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SMITH & ARCHITECTS204/17/2025
EP ENGINEERING LLC512/05/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PAUL FUSCO CONSULTING203/21/2026
JAM CONSULTANTS, INC.803/21/2026
METROPOLIS GROUP INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MJE MECHANICAL LLCGeneral Contractor303/21/2026
UL ELECTRICAL CORP.Electrical103/22/2026
KISHAN PLUMBING INCGeneral Contractor107/08/2026
LINMAR CONSTRUCTION CORPGeneral Contractor107/08/2026
CROWN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EP INSPECTIONS AND COMMIS7079704/17/2025
Building Lifecycle
All (81)Filed (7)Permit Issued (4)Signed Off (4)Violation (35)Inspection (3)Objection (10)Special Inspection (18)
01/23/2026
Violation issued (FDNY_ORDER, closed)
09/29/2025
Signed off — Alteration
INTERIOR ALTERATIONS TO INCLUDE PARTITION, MILLWORK AND FINISHES - BUILDING 3. NO CHANGE TO USE, OCCUPANCY OR EGRESS
Q01204425-I1
05/22/2025
Permit issued — General Construction
Q01204425-I1-GC
05/05/2025
Objection resolved — Addressed
05/05/2025
Objection resolved — Addressed
04/29/2025
Objection raised — Admin
04/29/2025
Objection raised — Scope
04/17/2025
Filed — Alteration
INTERIOR ALTERATIONS TO INCLUDE PARTITION, MILLWORK AND FINISHES - BUILDING 3. NO CHANGE TO USE, OCCUPANCY OR EGRESS
Q01204425-I1
04/16/2025
Special inspection requirement — Interior lighting power
MOLLY GLENN
04/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOLLY GLENN
04/02/2025
Special inspection requirement — Final
MOLLY GLENN
12/19/2024
Signed off — Alteration
Mechanical modification to include HVAC replacement and replacement of associated ductwork No change of use, occupancy or egress under this application
Q00816189-I1
12/18/2024
Permit issued — Mechanical Systems
Q00816189-I1-MS
12/10/2024
Signed off — Alteration
Replacement of existing fixtures, cap and piping plumbing work, no change of use or egress or occupancy under this application
Q00816233-I1
12/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
12/10/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
12/10/2024
Special inspection requirement — Maintenance information
Christopher Burgess
12/05/2024
Filed — Alteration
Replacement of existing fixtures, cap and piping plumbing work, no change of use or egress or occupancy under this application
Q00816233-P3
12/03/2024
Special inspection requirement — Maintenance information
Christopher Burgess
12/03/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
12/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
11/22/2024
Signed off — Alteration
Interior renovation of an existing office space, including the installation of non-load-bearing partitions and new partitions, and finishes. No change of use, egress, or occupancy is in accordance with the plans submitted with this application.
Q00815977-I1
02/29/2024
Filed — Alteration
Replacement of existing fixtures, cap and piping plumbing work, no change of use or egress or occupancy under this application
Q00816233-P1
02/24/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/22/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/03/2023
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
08/22/2023
Permit issued — Plumbing
Q00816233-I1-PL
08/15/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
08/15/2023
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Burgess
08/15/2023
Special inspection requirement — Shutoff dampers
Christopher Burgess
08/15/2023
Special inspection requirement — Mechanical Systems
Christopher Burgess
08/15/2023
Special inspection requirement — Maintenance information
Christopher Burgess
08/15/2023
Special inspection requirement — Duct leakage testing, insulation and design
Christopher Burgess
08/15/2023
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Burgess
08/15/2023
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
Christopher Burgess
08/15/2023
Special inspection requirement — Final
Christopher Burgess
08/10/2023
Filed — Alteration
Mechanical modification to include HVAC replacement and replacement of associated ductwork No change of use, occupancy or egress under this application
Q00816189-P1
08/08/2023
Permit issued — General Construction
Q00815977-I1-GC
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Objection raised — Scope
04/25/2023
Objection resolved — Addressed
Latest 60 of 81 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKISHAN PLUMBING INC05/22/2025
DOB NOWMechanical SystemsSigned-offMJE MECHANICAL LLC12/18/2024
DOB NOWPlumbingSigned-offCROWN PLUMBING INC08/22/2023
DOB NOWGeneral ConstructionSigned-offLINMAR CONSTRUCTION08/08/2023
BISMHISSUEDLINMAR CONSTRUCTION CORP01/10/2019
BISPLISSUEDPAR PLUMBING CO., INC06/19/2018
BISOTISSUEDLINMAR CONSTRUCTION CORP05/01/2018
BISOTISSUEDANJ CONSTRUCTION CORP10/14/2004
BISPLISSUEDDNA PLUMBING CONTR. INC12/09/2002
BISMHISSUEDCOOLING GUARD CORP11/13/2002
3 projects · most recent 04/04/2024
General Wiring
FiledStatusContractorScope
04/04/2024CompleteA.L. ELECTRICAL CORP.General Wiring
08/06/2018CompleteA.L. ELECTRICAL CORP.General Wiring
06/18/2018CompleteUL ELECTRICAL CORP.1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/24/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/03/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
04/16/2025Interior lighting powerMOLLY GLENNenergy_progress
04/16/2025Fire-Resistant Penetrations and JointsMOLLY GLENNspecial
04/02/2025FinalMOLLY GLENNprogress
12/10/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
12/10/2024HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
12/10/2024Maintenance informationChristopher Burgessenergy_progress
12/03/2024Maintenance informationChristopher Burgessenergy_progress
12/03/2024HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
12/03/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
08/15/2023HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
08/15/2023HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
08/15/2023Shutoff dampersChristopher Burgessenergy_progress
08/15/2023Mechanical SystemsChristopher Burgessspecial
08/15/2023Maintenance informationChristopher Burgessenergy_progress
08/15/2023Duct leakage testing, insulation and designChristopher Burgessenergy_progress
08/15/2023HVAC-R and service water heating equipmentChristopher Burgessenergy_progress
08/15/2023Exhaust and Vent Systems in Plenums and DuctsChristopher Burgessspecial
08/15/2023FinalChristopher Burgessprogress
▾Documents — 62 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/24/2026Q00816189-I1Request digital key ↗
08/24/2026Q00816189-P1Request digital key ↗
08/23/2026Q00816233-P3Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION4
12/22/2018421626832Open ↗
11/15/2018421626832Open ↗
04/30/2018421626832Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
01/14/2019421626832Open ↗
07/03/2018421626832Open ↗
05/10/2018421626832Open ↗
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026Q00815977-I1Open ↗
08/20/2026Q01204425-I1Open ↗
08/13/2026Q00816189-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/28/2026Q00816189-I1Open ↗
08/28/2026Q00816189-I1Open ↗
08/26/2026Q01204425-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
03/28/2019421626832Open ↗
01/05/2019421626832Open ↗
05/10/2018421626832Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026Q00816189-I1Open ↗
08/26/2026Q01204425-I1Open ↗
08/24/2026Q00816233-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/30/2018421626832Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/30/2018421626832Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
12/22/2018421626832Open ↗
11/15/2018421626832Open ↗
04/30/2018421626832Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
03/28/2019421626832Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/15/2026Q00815977-I1Open ↗
08/13/2026Q00816189-I1Open ↗
08/13/2026Q00816233-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/30/2018421618262Open ↗
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
04/30/2018421626832Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01204425-I1Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
01/05/2019421626832Open ↗
05/10/2018421626832Open ↗
04/30/2018421618262Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
03/28/2019421626832Open ↗
▸Approvals, Objections & Sign-offs4
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/13/2026Q01204425-I1Open ↗
08/13/2026Q00815977-I1Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/28/2019421626832Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/18/2019421626832Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/28/2019421626832Open ↗
04/30/2018421618262Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET2
04/30/2018421626832Open ↗
04/30/2018421626832Open ↗
▸BISADDITIONAL INFORMATION1
12/15/2018421626832Open ↗
▸BISBOROUGH INTAKE FORM1
11/15/2018421626832Open ↗