← Back
General warehouse
67 VAN DAM STREET
BROOKLYN · BIN 3258578
💬 Discuss this project
1992Year Built
1Stories
E1Building Class
M1-2Zoning
5,000 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
General warehouse · Owner of record: AAOL LLC · 5,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof3p · 1 filing · 3 docs
Floor 11p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
R M REALTY1607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/30/2021$2.4M—R & M MARCANTONIO REALTY CORP → AAOL LLC$480/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADAL ENGINEERING PLLC112/15/2022
WRG ENGINEERING, P.C.508/31/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DEPARTMENT OF DESIGN & CONSTRUCTION603/21/2026
WRG ENGINEERING P C403/21/2026
BIG ORANGE EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BELFOR LONG ISLAND LLCGeneral Contractor603/21/2026
ROBERT J. SANKEY P&H INCPlumbing303/22/2026
VILLAGE P & H NY INCPlumbing207/08/2026
AURA PLUMBING INCFire Protection107/08/2026
VILLAGE P H NYGeneral Contractor103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ADAL ENGINEERING PLLC4205112/15/2022
WRG ENGINEERING, P.C.4403508/31/2021
Building Lifecycle
All (28)Filed (6)Permit Issued (4)Signed Off (2)Violation (4)Inspection (2)Objection (6)Special Inspection (4)
02/20/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/14/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/28/2023
Permit issued — Sprinklers
B00795772-I1-EW-SP
12/15/2022
Filed — Alteration
Installation of new sprinkler system in one story commercial blg as per plans attached herewith. No change in use, egress and occupancy.
B00795772-I1
12/14/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dariusz Makara
08/18/2022
Special inspection requirement — Sprinkler Systems
Dariusz Makara
09/21/2021
Signed off — Alteration
Removal of existing shower and converting bathrooms to ADA compliance Bathrooms
B00358024-I1
09/09/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Winston Garcia
09/08/2021
Objection resolved — Addressed
09/01/2021
Objection raised — Scope
08/31/2021
Filed — Alteration
Removal of existing shower and converting bathrooms to ADA compliance Bathrooms
B00358024-P4
07/09/2021
Objection resolved — Addressed
07/02/2021
Objection raised — Scope
06/30/2021
Filed — Alteration
Removal of existing shower and converting bathrooms to ADA compliance Bathrooms
B00358024-P3
06/15/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Winston Garcia
02/18/2021
Signed off — Alteration
B00292070-I1
11/18/2020
Permit issued — Plumbing
B00358024-I1-PL
11/02/2020
Objection resolved — Addressed
10/30/2020
Objection raised — Other
10/29/2020
Filed — Alteration
Removal of existing shower and converting bathrooms to ADA compliance Bathrooms
B00358024-P2
07/08/2020
Permit issued — Structural
B00292070-I1-ST
06/19/2020
Filed — Alteration
Removal of existing shower and converting bathrooms to ADA compliance Bathrooms
B00358024-I1
05/05/2020
Permit issued — Structural
B00292070-I1-ST
01/21/2020
Filed — Alteration
B00292070-I1
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/08/2019
Violation issued (ECB, closed)
Construction
06/25/1992
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offAURA PLUMBING INC09/28/2023
DOB NOWPlumbingSigned-offVILLAGE P & H NY INC11/18/2020
DOB NOWStructuralSigned-offBELFOR LONG ISLAND LLC07/08/2020
DOB NOWStructuralSigned-offBELFOR LONG ISLAND LLC05/05/2020
BISOTISSUEDBELFOR LONG ISLAND LLC05/15/2020
BIS—ISSUEDOWNER02/22/1991
1 project · most recent 12/15/2022
FiledStatusContractorScope
12/15/2022Signed-offAURA PLUMBING INC—
1 project · most recent 12/15/2022
Water/Sanitary
FiledStatusContractorScope
12/15/2022——Water/Sanitary
1 project · most recent 09/10/2020
General Wiring
FiledStatusContractorScope
09/10/2020CompleteGOTHAM WIRING LICENSEDGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
02/20/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/14/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
12/14/2022Fire-Resistant Penetrations and JointsDariusz Makaraspecial
08/18/2022Sprinkler SystemsDariusz Makaraspecial
09/09/2021Fire-Resistant Penetrations and JointsWinston Garciaspecial
06/15/2021Fire-Resistant Penetrations and JointsWinston Garciaspecial
▾Documents — 42 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - Plumbing4
09/02/2026B00358024-I1Request digital key ↗
08/15/2026B00358024-P2Request digital key ↗
08/15/2026B00358024-P3Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Structural1
09/02/2026B00292070-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/28/2026B00795772-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
05/21/2020340716069Open ↗
02/12/2020340716069Open ↗
▸BISWORK PERMIT APPLICATION1
05/15/2020340716069Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/28/2026B00795772-I1Open ↗
08/13/2026B00358024-I1Open ↗
08/13/2026B00358024-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/25/2026B00358024-I1Open ↗
09/23/2026B00795772-I1Open ↗
09/23/2026B00795772-I1Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/12/2020340716069Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
02/12/2020340716069Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/28/2026B00795772-I1Open ↗
08/13/2026B00292070-I1Open ↗
08/13/2026B00358024-P4Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/12/2020340716069Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
02/18/2021340716069Open ↗
09/30/2020340716069Open ↗
04/14/2020340716069Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
02/18/2021340716069Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
02/18/2021340716069Open ↗
04/14/2020340716069Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/18/2021340716069Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/18/2021340716069Open ↗
04/14/2020340716069Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION4
09/30/2020340716069Open ↗
08/11/2020340716069Open ↗
04/14/2020340716069Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
02/12/2020340716069Open ↗