← Back
Predominantly retail with other uses
690 MADISON AVENUE
MANHATTAN · Upper East Side-Carnegie Hill · BIN 1040891
💬 Discuss this project
1879Year Built
5Stories
K4Building Class
C5-1Zoning
6,620 sfGross Floor Area
1Units
Rent Stabilized20 Open Violations ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: 690 MADISON AVENUE LLC · 1,429 sf lot · 4.63 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Roof116p · 6 filings · 20 docs
Floor 5173p · 8 filings · 20 docs
Floor 4176p · 8 filings · 20 docs
Floor 3173p · 7 filings · 20 docs
Floor 2169p · 8 filings · 20 docs
Floor 1174p · 8 filings · 20 docs
Cellar132p · 6 filings · 20 docs
Site & exterior9p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SL GREEN REALTY CORP5707/08/2026
HERMES OF PARIS3003/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/05/2024$34.0M—— → —$5,136/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
OUTSOURCE CONSULTANTS, INC.1803/21/2026
SPRING SCAFFOLDING LLC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SCHIMENTI CONSTRUCTION COGeneral Contractor1307/08/2026
SPRING SCAFFOLDING LLCGeneral Contractor407/08/2026
BEDROCK MECHANICAL INCFire Protection107/08/2026
BEDROCK PLBG. & HTG., INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DNA CONTROLLED INSPECTION554611/26/2024
ROSINI ENGINEERING, PC3282510/18/2024
THE EIPEL ENGINEERING GRO2714208/13/2024
SOCOTEC ENGINEERING4983411/27/2023
Building Lifecycle
All (136)Filed (21)Permit Issued (11)Signed Off (9)Violation (60)Inspection (7)Special Inspection (28)
02/19/2026
Signed off — Alteration
STRUCTURAL WORK AS SHOWN ON PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
M00952382-S1
12/12/2025
Violation issued (ECB, closed)
Elevators
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/05/2025
Signed off — Alteration
MECHANICAL WORK AS SHOWN ON PLANS FILED HEREWITH ON FLOORS CELLAR, 001-005, ROOF.
M00952376-I1
08/21/2025
Signed off — Alteration
GENERAL CONSTRUCTION FOR INTERIOR RENOVATIONS ON FLOORS CEL, 001-005, ROOF AS INDICATED ON PLANS
M00962503-I1
08/21/2025
Signed off — Alteration
EXTERIOR CONSTRUCTION INCLUDING FACADE WORK AS SHOWN ON PLANS FILED HEREWITH . NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
M00953294-I1
06/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/29/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLAN. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
M01005092-I1
12/16/2024
Signed off — Alteration
SPRINKLER MODIFICATIONS AS SHOWN ON PLANS FIILED HEREWITH, INCLUDING TEMPORARY CORE SPRINKLER PROTECTION ON CELLAR, 001-005, ROOF.
M00952380-I1
12/04/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
11/26/2024
Filed — Alteration
PLUMBING WORK AS SHOWN ON PLANS FILED HEREWITH ON FLOORS CELLAR, 001-005, ROOF.
M00952378-P2
11/26/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/21/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/20/2024
Signed off — Alteration
STRUCTURAL WORK AS SHOWN ON PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
M00952382-I1
11/08/2024
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLAN. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
M01005092-S1
11/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM FITZJOHN
10/18/2024
Filed — Alteration
SPRINKLER MODIFICATIONS AS SHOWN ON PLANS FIILED HEREWITH, INCLUDING TEMPORARY CORE SPRINKLER PROTECTION ON CELLAR, 001-005, ROOF.
M00952380-P2
10/18/2024
Filed — Alteration
MECHANICAL WORK AS SHOWN ON PLANS FILED HEREWITH ON FLOORS CELLAR, 001-005, ROOF.
M00952376-P1
10/18/2024
Special inspection requirement — Mechanical Systems
David Rosini
10/18/2024
Special inspection requirement — Final
David Rosini
10/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM FITZJOHN
10/18/2024
Special inspection requirement — Sprinkler Systems
David Rosini
10/16/2024
Special inspection requirement — Sprinkler Systems
David Rosini
10/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/19/2024
Filed — Alteration CO
Alt-1 application for change of use on the 5th floor to commercial retail space as indicated on plans. No change of egress, obtain a new C of O.
M00952370-P3
09/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM FITZJOHN
08/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/22/2024
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
08/15/2024
Special inspection requirement — Final
Joseph Tarella
08/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
08/13/2024
Filed — Alteration
PLUMBING WORK AS SHOWN ON PLANS FILED HEREWITH ON FLOORS CELLAR, 001-005, ROOF.
M00952378-P1
08/13/2024
Filed — Alteration
SPRINKLER MODIFICATIONS AS SHOWN ON PLANS FIILED HEREWITH, INCLUDING TEMPORARY CORE SPRINKLER PROTECTION ON CELLAR, 001-005, ROOF.
M00952380-P1
08/13/2024
Filed — Alteration
GENERAL CONSTRUCTION FOR INTERIOR RENOVATIONS ON FLOORS CEL, 001-005, ROOF AS INDICATED ON PLANS
M00962503-P1
08/13/2024
Filed — Alteration
STRUCTURAL WORK AS SHOWN ON PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
M00952382-P1
08/05/2024
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Bix Ellenbecker
08/05/2024
Special inspection requirement — Final
Bix Ellenbecker
08/05/2024
Special inspection requirement — Structural Wood Frame
Bix Ellenbecker
08/05/2024
Special inspection requirement — Final
Joseph Tarella
08/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM FITZJOHN
08/05/2024
Special inspection requirement — Sprinkler Systems
David Rosini
08/05/2024
Special inspection requirement — Concrete - Cast-In-Place
Bix Ellenbecker
08/05/2024
Special inspection requirement — Masonry
Bix Ellenbecker
08/05/2024
Special inspection requirement — Post-installed Anchors
Bix Ellenbecker
08/05/2024
Special inspection requirement — Structural Cold-Formed Steel
Bix Ellenbecker
08/05/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Bix Ellenbecker
08/05/2024
Special inspection requirement — Structural Steel - Details
Bix Ellenbecker
08/05/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Bix Ellenbecker
08/05/2024
Special inspection requirement — Structural Steel - Welding
Bix Ellenbecker
08/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM FITZJOHN
07/25/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/24/2024
Filed — Alteration CO
Alt-1 application for change of use on the 5th floor to commercial retail space as indicated on plans. No change of egress, obtain a new C of O.
M00952370-P1
07/01/2024
Permit issued — General Construction
M00952370-I1-GC
05/20/2024
Signed off — Alteration
INTERIOR NON-STRUCTURAL DEMOLITION AS INDICATED ON PLANS FILEDHEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
M00857888-I1
03/22/2024
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLAN. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
M01005092-P1
02/16/2024
Permit issued — General Construction
M00953294-I1-GC
02/13/2024
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLAN. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
M01005092-I1
Latest 60 of 136 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedSCHIMENTI CONSTRUCTION CO07/01/2024
DOB NOWGeneral ConstructionSigned-offSCHIMENTI CONSTRUCTION CO02/16/2024
DOB NOWSupported ScaffoldSigned-offSPRING SCAFFOLDING LLC02/13/2024
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC02/13/2024
DOB NOWPlumbingSigned-offBEDROCK PLBG. & HTG., INC01/11/2024
DOB NOWSprinklersSigned-offBEDROCK MECHANICAL INC01/11/2024
DOB NOWGeneral ConstructionPermit IssuedSCHIMENTI CONSTRUCTION CO01/02/2024
DOB NOWStructuralSigned-offSCHIMENTI CONSTRUCTION CO12/01/2023
DOB NOWFoundationSigned-offSCHIMENTI CONSTRUCTION CO12/01/2023
DOB NOWGeneral ConstructionSigned-offSCHIMENTI CONSTRUCTION CO12/01/2023
DOB NOWMechanical SystemsSigned-offSCHIMENTI CONSTRUCTION CO12/01/2023
BISSPISSUEDUNITED FIRE PROT CORP10/16/2020
BISOTISSUEDDICKINSON CAMERON CONSTRUCTION10/04/2010
BISEQISSUEDS&E BRIDGE & SCAFFOLD LLC.09/10/2010
BISEQISSUEDS&E BRIDGE & SCAFFOLD LLC.07/16/2010
BISBLISSUEDMACCARONE PLUMBING INC01/28/2010
BISOTISSUEDSHAWMUT WOODWORKING & SUPPLY11/06/2009
BISMHISSUEDSHAWMUT WOODWORKING & SUPPLY11/06/2009
BISPLISSUEDMACCARONE PLUMBING INC10/02/2009
BISMHISSUEDSHAWMUT WOODWORKING & SUPPLY09/30/2009
BISOTISSUEDSHAWMUT WOODWORKING & SUPPLY07/28/2009
BISOTISSUEDSHAWMUT WOODWORKING & SUPPLY07/01/2009
BISMHISSUEDSHAWMUT WOODWORKING & SUPPLY06/29/2009
BIS—ISSUEDSHAWMUT WOODWORKING & SUPPLY06/26/2009
BISEQISSUEDALLSAFE LLC06/15/2009
BISOTISSUEDAMERICON CONSTRUCTION INC.11/19/2008
BISMHISSUEDAMERICON CONSTRUCTION INC.11/19/2008
BISOTISSUEDVENEZIA INTERIORS CORP04/24/2001
BIS—ISSUEDTRIAD PROJECT MGMT04/01/1996
BISPLISSUEDGREENE MECH. C03/28/1996
BISSPISSUEDSUNSET PLG & FIRE PROTECTION03/21/1996
BISMHISSUEDTRIAD PROJECT MGMT LTD02/13/1996
BISOTISSUEDTRIAD PROJECT MGMT LTD01/31/1996
BISEQISSUEDTRIAD PROJECT MANAGEMENT LTD01/31/1996
BISOTISSUEDTRIAD PROJECT MGMT LTD01/31/1996
BISPLISSUEDKAPLAN BRESLAW INC01/18/1996
BISOTISSUEDTRIAD PROJECT MGMT LTD10/03/1995
BISMHISSUEDTRIAD PROJECT MGMT LTD10/03/1995
BISEQISSUEDATLANTIC SCAFFOLDING08/31/1995
BISOTISSUEDTRIAD PROJECT MANAGEMENT LTD08/29/1995
+ 1 more permits on file
1 project · most recent 11/26/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
11/26/2024Signed-offBEDROCK PLBG. & HTG., INCGas, Storm, Water/Sanitary
5 projects · most recent 05/22/2024
General Wiring
FiledStatusContractorScope
05/22/2024CompleteALLIANCE ELEVATOR COMPANY—
01/05/2024Permit IssuedLIVE WIRE ELECTRIC 1 LLCGeneral Wiring
12/03/2023CompleteALLIANCE ELEVATOR COMPANY—
10/30/2023CompleteTOP SHELF ELECTRIC CORP—
06/06/2023CompleteM.C. ELECTRICAL NY INC—
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
06/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/04/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/26/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/21/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/30/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/22/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
07/25/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
11/27/2024Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
11/05/2024Fire-Resistant Penetrations and JointsWILLIAM FITZJOHNspecial
10/18/2024Mechanical SystemsDavid Rosinispecial
10/18/2024FinalDavid Rosiniprogress
10/18/2024Fire-Resistant Penetrations and JointsWILLIAM FITZJOHNspecial
10/18/2024Sprinkler SystemsDavid Rosinispecial
10/16/2024Sprinkler SystemsDavid Rosinispecial
10/01/2024Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
09/11/2024Fire-Resistant Penetrations and JointsWILLIAM FITZJOHNspecial
08/15/2024FinalJoseph Tarellaprogress
08/15/2024Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
08/05/2024Subsurface Conditions – Fill Placement & In-Place DensityBix Ellenbeckerspecial
08/05/2024FinalBix Ellenbeckerprogress
08/05/2024Structural Wood FrameBix Ellenbeckerprogress
08/05/2024FinalJoseph Tarellaprogress
08/05/2024Fire-Resistant Penetrations and JointsWILLIAM FITZJOHNspecial
08/05/2024Sprinkler SystemsDavid Rosinispecial
08/05/2024Concrete - Cast-In-PlaceBix Ellenbeckerspecial
08/05/2024MasonryBix Ellenbeckerspecial
08/05/2024Post-installed AnchorsBix Ellenbeckerspecial
08/05/2024Structural Cold-Formed SteelBix Ellenbeckerspecial
08/05/2024Structural Stability – Alterations of existing buildingsBix Ellenbeckerspecial
08/05/2024Structural Steel - DetailsBix Ellenbeckerspecial
08/05/2024Structural Steel - High Strength BoltingBix Ellenbeckerspecial
08/05/2024Structural Steel - WeldingBix Ellenbeckerspecial
Latest 25 of 28.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Van Cleef & ArpelsRetailCellar, Floors 1–5, Roof
Project M00953294 Alteration · LOC Issued · 02/05/2024
Project M00952370 Alteration CO · Permit Entire · 11/27/2023
Project M00952382 Alteration · LOC Issued · 11/27/2023
Project M00962503 Alteration · LOC Issued · 11/27/2023
Project M00952376 Alteration · LOC Issued · 11/22/2023
Project M00952380 Alteration · LOC Issued · 11/22/2023
Project M00857888 Alteration · LOC Issued · 04/17/2023
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 429 on file (BIS + DOB NOW)
▸Plans & Drawings21
▸DOB NOWPlans/Sketch21
08/31/2026M00857888-I1Request digital key ↗
08/28/2026M00952382-I1Request digital key ↗
08/28/2026M00952382-P1Request digital key ↗
Showing 3 of 21 on file for this type
▸Applications & Permits84
▸BISPLAN / WORK APPROVAL APPLICATION43
11/12/2025120093718Open ↗
11/12/2025104425089Open ↗
11/12/2025120033347Open ↗
Showing 3 of 43 on file for this type
▸BISWORK PERMIT APPLICATION24
10/19/2020120093683Open ↗
10/12/2010120093692Open ↗
09/16/2010120468314Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWLPC Approval/Permit15
08/13/2026M00952382-I1Open ↗
08/13/2026M00952378-I1Open ↗
08/13/2026M00962503-P1Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
08/17/2020120093683Open ↗
▸Seals & Professional Certifications106
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION38
09/27/2011120071359Open ↗
09/27/2011120071359Open ↗
08/19/2011120093683Open ↗
Showing 3 of 38 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature21
09/05/2026M00952380-P2Open ↗
09/02/2026M00952382-P1Open ↗
09/02/2026M00952382-P1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature21
08/31/2026M00857888-I1Open ↗
08/28/2026M00952382-I1Open ↗
08/28/2026M00952382-P1Open ↗
Showing 3 of 21 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM10
09/16/2010120468314Open ↗
07/28/2010120424308Open ↗
07/20/2010120416246Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST9
09/17/2010120468314Open ↗
07/28/2010120424308Open ↗
07/20/2010120416246Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/02/2026M00952382-P1Open ↗
09/02/2026M00952382-P1Open ↗
09/01/2026M00953294-I1Open ↗
Showing 3 of 7 on file for this type
▸Trade Schedules & Equipment34
▸BISEQUIPMENT USE PERMITS14
01/26/2011120093709Open ↗
01/26/2011120093709Open ↗
01/26/2011120093709Open ↗
Showing 3 of 14 on file for this type
▸BISSELF-CERT PLUMBING NOTICE7
07/01/2010120093709Open ↗
03/11/2010120093683Open ↗
02/16/2010120093709Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING5
08/17/2020120093683Open ↗
02/23/2010120093709Open ↗
01/15/2010120093683Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION-PERMIT4
01/26/2011120093709Open ↗
01/26/2011120093709Open ↗
01/06/2011120093709Open ↗
Showing 3 of 4 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA2
09/29/2010120293306Open ↗
06/22/2010120293306Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
01/20/2010120247599Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
02/11/2010120093709Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist3
08/13/2026M00952370-P3Open ↗
08/13/2026M00952370-I1Open ↗
08/13/2026M00952370-P1Open ↗
▸BISSTREET TREE CHECKLIST1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos37
▸DOB NOWDEP ACP-5: Asbestos Assessment Report18
08/31/2026M00857888-I1Open ↗
08/28/2026M00952382-S1Open ↗
08/28/2026M00952382-I1Open ↗
Showing 3 of 18 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'14
07/28/2010120424308Open ↗
07/27/2010120424308Open ↗
03/16/2010120293306Open ↗
Showing 3 of 14 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER5
09/16/2010120468314Open ↗
07/20/2010120416246Open ↗
01/20/2010120247599Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports10
▸BISTECHNICAL REPORT: RESPONSIBILITY3
11/13/2020120093683Open ↗
11/13/2020120093683Open ↗
08/17/2020120093683Open ↗
▸BISSTRUCTURAL STEEL - WELDING2
08/25/2022120033347Open ↗
08/25/2022120033347Open ↗
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS1
08/25/2022120033347Open ↗
▸BISHYDRAULIC FLOW CALCULATIONS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISCONCRETE - CAST-IN-PLACE1
08/25/2022120033347Open ↗
▸BISSTRUCTURAL STEEL - HIGH STRENGTH BOLTING1
08/25/2022120033347Open ↗
▸BISHYDRO FLOW TEST LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs67
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST37
02/01/2021120035087Open ↗
11/13/2020120093683Open ↗
11/09/2020120035087Open ↗
Showing 3 of 37 on file for this type
▸BISADMINISTRATIVE OBJECTIONS15
09/17/2010120468314Open ↗
07/28/2010120424308Open ↗
07/20/2010120416246Open ↗
Showing 3 of 15 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
02/15/2011120095011Open ↗
09/29/2010120293306Open ↗
05/06/2010120093692Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
01/29/2010120035087Open ↗
01/20/2010120035087Open ↗
Showing 2 of 4 on file for this type
▸BISLANDMARKS APPROVAL3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISLANDMARKS SIGNOFF2
10/24/2022120033347Open ↗
10/24/2022120035087Open ↗
▸BISSUPERSEDING LETTER1
10/19/2020120093683Open ↗
▸BISFINAL1
10/31/2022120033347Open ↗
▸Cost, Insurance & Ownership23
▸BISCOST AFFIDAVIT20
11/13/2020120093683Open ↗
08/17/2020120093683Open ↗
02/15/2011120095011Open ↗
Showing 3 of 20 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
10/13/2022120035087Open ↗
08/25/2022120033347Open ↗
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
11/14/2016120035087Open ↗
▸Filing & Intake Forms25
▸BISBOROUGH INTAKE FORM12
01/24/2020120035087Open ↗
11/04/2019120035087Open ↗
08/13/2019120035087Open ↗
Showing 3 of 12 on file for this type
▸BISADDITIONAL INFORMATION8
08/17/2020120093683Open ↗
10/17/2016120035087Open ↗
10/17/2016120035087Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING COVER SHEET5
09/17/2010120468314Open ↗
07/28/2010120424308Open ↗
07/20/2010120416246Open ↗
Showing 3 of 5 on file for this type
▸Other Documents18
▸DOB NOWProof of Historic Building12
08/13/2026M00952378-I1Open ↗
08/13/2026M00962503-P1Open ↗
08/13/2026M00952378-P1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProperty Ownership Certification3
08/13/2026M00952370-P1Open ↗
08/13/2026M00952370-P3Open ↗
08/13/2026M00952370-I1Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
01/05/2011110350236Open ↗
▸BISSupporting Document: Fee Except1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPLOT DIAGRAM1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type