← Back
Elevator apt, semi-fireproof without stores
715 NOBLE AVENUE
BRONX · BIN 2092699
💬 Discuss this project
1967Year Built
6Stories
D1Building Class
R6Zoning
225,216 sfGross Floor Area
174Units
LL97 CoveredRent Stabilized49 Open Violations 48 unresolved · 1 paperwork only ▸FISP: SAFE
Elevator apt, semi-fireproof without stores · Owner of record: NYC HOUSING AUTHORITY · 110,000 sf lot · 2.05 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction71p · 1 filing · 20 docs
Floor 6Under Construction61p · 1 filing · 20 docs
Floor 5Under Construction63p · 1 filing · 20 docs
Floor 4Under Construction59p · 1 filing · 20 docs
Floor 3Under Construction61p · 1 filing · 20 docs
Floor 2Under Construction66p · 1 filing · 20 docs
Floor 1Under Construction70p · 1 filing · 20 docs
CellarUnder Construction81p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK CITY HOUSING AUTHORITY2507/08/2026
DOUGLASTON DEVELOPMENT1507/08/2026
J E LEVINE BUILDER103/22/2026
LEVINE BUILDERS103/22/2026
CARLITOS CONTRACTING103/22/2026
NYCHA303/21/2026
S N BUILDERS203/21/2026
NYC HOUSING AUTHORITY503/21/2026
ABA SACK WERN LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.2003/21/2026
A1 EXPEDITING SERVICE203/21/2026
Rigid Structural Design, LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CARLITOS CONTRACTING CORPGeneral Contractor404/09/2026
DUAL FUEL PLUBING & HTINGPlumbing307/08/2026
J.E. LEVINE BUILDER INCGeneral Contractor207/08/2026
VIEW 360 CONSTRUCTION INCGeneral Contractor207/08/2026
RYAN JOSEPHElectrical203/21/2026
ANTHONY CERRITOElectrical203/21/2026
D.D.S. MECH PBG&HTG CORPPlumbing107/08/2026
INPRO PLUMBING CORPPlumbing107/08/2026
A & R ELEC'L MAINT. INC.Electrical103/22/2026
DILPREET SINGHElectrical103/21/2026
LIT MODE ELECL CONTG INCElectrical103/22/2026
DUAL FUEL COMPANY LLCGeneral Contractor107/08/2026
HISPANIC ENTERPRISES INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
20/20 INSPECTIONS INC1471211/24/2025
MILROSE CONSULTANTS LLC2003702/27/2025
Building Lifecycle
All (136)Filed (15)Permit Issued (13)Signed Off (4)Facade (FISP) (16)Violation (49)Inspection (7)Objection (2)Special Inspection (30)
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
A
04/29/2026
Violation issued (HPD, closed)
C
04/21/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/19/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/27/2026
Permit issued — General Construction
X00883731-I1-GC
12/30/2025
Cycle 9 facade report signed — SAFE
12/24/2025
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING IN PUBLIC AREAS: REPLACE EXISTING FIXTURES AND EQUIPMENT WITH NEW AS DIRECTED. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X00883731-S6
12/23/2025
Cycle 9 facade report submitted
12/19/2025
Cycle 9 facade inspection completed
12/10/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/03/2025
Signed off — Alteration
X01088736-I1
12/02/2025
Permit issued — Structural
X00883731-S5-ST
11/28/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/26/2025
Signed off — Alteration
NYCHA EMERGENCY WORK FOR RESIDENTIAL COOKING GAS: PROPOSED RESIDENTIAL COOKING GAS PIPE REPLACEMENT WORK AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00996349-I1
11/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACOB HAAS
11/25/2025
Special inspection requirement — Tenant Protection Plan Compliance
JACOB HAAS
11/24/2025
Filed — Alteration
NYCHA EMERGENCY WORK FOR RESIDENTIAL COOKING GAS: PROPOSED RESIDENTIAL COOKING GAS PIPE REPLACEMENT WORK AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00996349-P1
11/24/2025
Special inspection requirement — Tenant Protection Plan Compliance
JACOB HAAS
11/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACOB HAAS
10/20/2025
Violation issued (HPD, closed)
A
10/20/2025
Violation issued (HPD, closed)
A
10/20/2025
Violation issued (HPD, closed)
A
10/20/2025
Violation issued (HPD, closed)
C
10/20/2025
Violation issued (HPD, closed)
C
10/20/2025
Violation issued (HPD, closed)
C
10/20/2025
Violation issued (HPD, closed)
C
10/20/2025
Violation issued (HPD, closed)
A
10/20/2025
Violation issued (HPD, closed)
A
07/23/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/22/2025
Signed off — Alteration
FACADE INSPECTION
X00990147-I1
07/16/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/09/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING IN PUBLIC AREAS: REPLACE EXISTING FIXTURES AND EQUIPMENT WITH NEW AS DIRECTED. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X00883731-P4
06/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Drutjons
06/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Drutjons
06/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Drutjons
06/30/2025
Special inspection requirement — Tenant Protection Plan Compliance
06/11/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING IN PUBLIC AREAS: REPLACE EXISTING FIXTURES AND EQUIPMENT WITH NEW AS DIRECTED. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X00883731-P3
05/13/2025
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Drutjons
05/13/2025
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Drutjons
05/13/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Drutjons
05/13/2025
Special inspection requirement — Tenant Protection Plan Compliance
04/16/2025
Violation issued (ECB, closed)
Unknown
03/17/2025
Filed — Alteration
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X01181236-I1
03/17/2025
Permit issued — Supported Scaffold
X01181236-I1-SF
03/06/2025
Violation issued (HPD, closed)
C
03/06/2025
Violation issued (HPD, closed)
C
03/06/2025
Violation issued (HPD, closed)
C
03/04/2025
Permit issued — Structural
X00883731-S6-GC-CX
03/03/2025
Permit issued — Plumbing
X00883731-S1-PL
03/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Drutjons
03/03/2025
Special inspection requirement — Final
Christopher Drutjons
03/03/2025
Special inspection requirement — Tenant Protection Plan Compliance
Christopher Drutjons
03/03/2025
Special inspection requirement — Mechanical Systems
Christopher Drutjons
03/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
Latest 60 of 136 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedJ.E. LEVINE BUILDER INC01/27/2026
DOB NOWStructuralPermit IssuedHISPANIC ENTERPRISES12/02/2025
DOB NOWSupported ScaffoldPermit IssuedVIEW 360 CONSTRUCTION INC03/17/2025
DOB NOWStructuralSigned-offVIEW 360 CONSTRUCTION INC03/04/2025
DOB NOWPlumbingSigned-offINPRO PLUMBING CORP03/03/2025
DOB NOWPlumbingSigned-offDUAL FUEL PLUBING & HTING02/20/2025
DOB NOWMechanical SystemsSigned-offDUAL FUEL COMPANY LLC02/18/2025
DOB NOWGeneral ConstructionPermit IssuedJ.E. LEVINE BUILDER INC02/14/2025
DOB NOWSidewalk ShedSigned-offCARLITOS CONTRACTING CORP01/22/2025
DOB NOWSidewalk ShedSigned-offCARLITOS CONTRACTING CORP01/22/2025
DOB NOWSuspended ScaffoldPermit IssuedJEPOL CONSTRUCTION INC06/07/2024
DOB NOWPlumbingSigned-offD.D.S. MECH PBG&HTG CORP03/04/2024
DOB NOWSuspended ScaffoldPermit IssuedJEPOL CONSTRUCTION INC01/24/2024
BISOTISSUEDS & N BUILDERS INC10/13/2015
BISEQISSUEDS & N BUILDERS INC08/07/2015
BISOTISSUEDS & N BUILDERS INC09/29/2014
BISEQISSUEDS & N BUILDERS INC09/29/2014
BISOTISSUEDS & N BUILDERS INC04/15/2014
BISEQISSUEDS & N BUILDERS INC11/29/2013
BISPLISSUEDDELPHI PLBG. & HTG., INC02/27/2009
BISPLISSUEDDELPHI PLBG. & HTG., INC02/14/2008
BISBLISSUEDDOUGLAS SIMMONS11/26/2007
BISPLISSUEDARISTA PLBG & HTG CORP01/26/2004
BISPLISSUEDMARIC PLBG & HTG INC05/04/2000
BISBLISSUEDDOUGLAS SIMMONS05/04/2000
BISOTISSUEDD & S PLUMBING & HEATING CORP.03/26/1999
BISEQISSUEDDORIEL SCAFFOLDING INC10/29/1998
BISEQISSUEDSPIDER CONSTRUCTION & WATERPROOF02/20/1998
BISPLISSUEDTRATAROS PLBG/ACE CONSTRUCTION11/19/1997
BISOTISSUEDTRATAROS PLUMBING11/07/1997
BISOTISSUEDD&S PLG & HTG CORP/ZAFFUTO CONST04/20/1995
BISPLISSUEDD&S PLG. & HTG. CORP/ZAFFUTO CON04/20/1995
1 project · most recent 07/09/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/09/2025Permit IssuedJ.E. LEVINE BUILDER INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Innova AWP10N3L2 8,000 BTU · Heat Pump Outdoor ×368
AWP10R3L2 8,330 BTU · Heat Pump Outdoor ×2
Ventilation
Panasonic FV-0511VQ1 80 CFM · Exhaust Fan ×2
Ruskin S11 300 CFM · Erv ×2
1 project · most recent 07/09/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/09/2025Signed-offINPRO PLUMBING CORPGas, Storm, Water/Sanitary
8 projects · most recent 02/09/2026
General Wiring
FiledStatusContractorScope
02/09/2026CompleteA & R ELEC'L MAINT. INC.—
02/09/2026CompleteA & R ELEC'L MAINT. INC.—
02/06/2026CompleteSUNKEEPER SOLAR LLC2 meters, 1 new_meters
06/26/2025CompleteWIRETECH ELECTRIC CORPGeneral Wiring
04/15/2025Permit IssuedDENALI ELECTRIC CORP—
04/11/2025CompleteWIRETECH ELECTRIC CORPGeneral Wiring
11/20/2024CompleteA & R ELEC'L MAINT. INC.General Wiring
08/05/2024Permit IssuedLIT MODE ELECL CONTG INC—
1 project · most recent 07/09/2025
Steel Concrete Masonry Wood
FiledStatusContractorScope
07/09/2025Permit IssuedJ.E. LEVINE BUILDER INCSteel, Concrete, Masonry, Wood
1 project · most recent 03/17/2025
Scaffold
FiledStatusContractorScope
03/17/2025Permit IssuedVIEW 360 CONSTRUCTION INCScaffold
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/21/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/19/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/10/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/28/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/23/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/16/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/11/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
11/25/2025Fire-Resistant Penetrations and JointsJACOB HAASspecial
11/25/2025Tenant Protection Plan ComplianceJACOB HAASspecial
11/24/2025Tenant Protection Plan ComplianceJACOB HAASspecial
11/24/2025Fire-Resistant Penetrations and JointsJACOB HAASspecial
06/30/2025HVAC-R and service water piping design and insulationChristopher Drutjonsenergy_progress
06/30/2025HVAC-R and service water heating system controlsChristopher Drutjonsenergy_progress
06/30/2025HVAC-R and service water heating equipmentChristopher Drutjonsenergy_progress
06/30/2025Tenant Protection Plan Compliance—special
05/13/2025HVAC-R and service water heating equipmentChristopher Drutjonsenergy_progress
05/13/2025HVAC-R and service water heating system controlsChristopher Drutjonsenergy_progress
05/13/2025HVAC-R and service water piping design and insulationChristopher Drutjonsenergy_progress
05/13/2025Tenant Protection Plan Compliance—special
03/03/2025HVAC-R and service water heating equipmentChristopher Drutjonsenergy_progress
03/03/2025FinalChristopher Drutjonsprogress
03/03/2025Tenant Protection Plan ComplianceChristopher Drutjonsspecial
03/03/2025Mechanical SystemsChristopher Drutjonsspecial
03/03/2025Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
03/03/2025HVAC-R and service water heating system controlsChristopher Drutjonsenergy_progress
03/03/2025HVAC-R and service water piping design and insulationChristopher Drutjonsenergy_progress
03/03/2025Maintenance informationChristopher Drutjonsenergy_progress
03/03/2025Energy Code Compliance InspectionsChristopher Drutjonsprogress
02/12/2025Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
02/12/2025Mechanical SystemsChristopher Drutjonsspecial
02/12/2025Tenant Protection Plan Compliance—special
02/12/2025Energy Code Compliance InspectionsChristopher Drutjonsprogress
Latest 25 of 51.
▾Documents — 192 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/21/2026X00990147-I1Request digital key ↗
08/21/2026X00996349-P1Request digital key ↗
08/21/2026X00996349-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits24
▸BISPLAN / WORK APPROVAL APPLICATION12
12/11/2015220471987Open ↗
12/08/2015220336848Open ↗
10/06/2015220471987Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION11
10/14/2015220471987Open ↗
10/14/2015220471987Open ↗
09/09/2015220471987Open ↗
Showing 3 of 11 on file for this type
▸BISAFTER-HOUR WORK PERMIT APPLICATION1
11/25/2014220336848Open ↗
▸Seals & Professional Certifications70
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION23
03/14/2016220471987Open ↗
02/12/2016220471987Open ↗
01/15/2016220471987Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/21/2026X00996349-P1Open ↗
08/21/2026X00996349-I1Open ↗
08/20/2026X01088736-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
09/29/2026X00883731-P4Open ↗
08/27/2026X00883731-S5Open ↗
08/26/2026X00883731-P3Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/28/2026X00996349-I1Open ↗
08/28/2026X00996349-P1Open ↗
08/27/2026X00883731-S5Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
08/06/2015240108842Open ↗
11/29/2013240042930Open ↗
11/27/2013240042921Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY4
08/06/2015240108842Open ↗
11/29/2013240042930Open ↗
11/27/2013240042921Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION4
08/06/2015240108842Open ↗
11/29/2013240042930Open ↗
11/27/2013240042921Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/30/2013220336848Open ↗
▸BISPC FULL REPORT1
10/16/2007210018675Open ↗
▸Trade Schedules & Equipment4
▸BISPLUMBING - SUPPORTING DOCUMENTATION2
10/23/2009210018675Open ↗
10/23/2009210018675Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
10/23/2009210018675Open ↗
10/23/2009210018675Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/21/2026X00996349-I1Open ↗
08/19/2026X00883731-S3Open ↗
08/19/2026X00883731-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/09/2015220471987Open ↗
08/06/2015240108842Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)2
01/19/2016220336848Open ↗
04/16/2014220336848Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
10/16/2007210018675Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
01/05/2016220336848Open ↗
09/30/2013220336848Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/13/2016220336848Open ↗
▸BISTR8: Energy Code Progress Inspections1
04/16/2014220336848Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
11/27/2013240042921Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: RESPONSIBILITY4
08/06/2015240108842Open ↗
11/29/2013240042930Open ↗
11/27/2013240042921Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
01/05/2016220336848Open ↗
04/16/2014220336848Open ↗
▸BISMANUFACTURE STATEMENT: QUALITY OF MASONRY UNITS-REQUIRED PRIOR TO CONSTRUCTION OF MASONRY (B FORM 10H)1
03/06/2014220336848Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
08/06/2015240108842Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
03/06/2014220336848Open ↗
▸Approvals, Objections & Sign-offs37
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter14
08/21/2026X00996349-P1Open ↗
08/21/2026X00996349-I1Open ↗
08/20/2026X01088736-I1Open ↗
Showing 3 of 14 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST13
03/14/2016220471987Open ↗
03/08/2016220471987Open ↗
02/12/2016220471987Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDEP Variance (V5) letter6
08/13/2026X00883731-S1Open ↗
08/13/2026X00883731-S5Open ↗
08/13/2026X00883731-S2Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
12/01/2015240108842Open ↗
08/30/2010210018675Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/16/2007210018675Open ↗
▸BISLANDMARKS APPROVAL1
09/29/2014240042921Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
02/12/2016220471987Open ↗
01/05/2016220336848Open ↗
09/02/2015220471987Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms10
▸BISEFILING JOB APPLICATION COVER SHEET4
08/06/2015240108842Open ↗
11/29/2013240042930Open ↗
11/27/2013240042921Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION4
01/15/2016220471987Open ↗
12/08/2015220336848Open ↗
09/04/2015240108842Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET2
09/02/2015220471987Open ↗
09/30/2013220336848Open ↗
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026X00883731-S6Open ↗
▸DOB NOWIRA Certification1
08/13/2026X00990147-I1Open ↗