← Back
Two family converted from one family
72-66 YELLOWSTONE BLVD
QUEENS · BIN 4074847
💬 Discuss this project
1940Year Built
1Stories
B3Building Class
R4BZoning
1,892 sfGross Floor Area
2Units
0 Open Violations
Two family converted from one family · 2,200 sf lot · 0.86 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof1p · 1 filing · 20 docs
Floor 21 filing · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KAJ NY CONSTRUCTION407/08/2026
KAIETEUR CONSTRUCTION303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/31/2023$1.3M—— → —$693/sf building
11/17/2021$700K—— → —$370/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J.K.DESIGN510/24/2022
MOHAMMAD AHEAD, PE104/06/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAIETEUR CONSTRUCTION INC.General Contractor307/08/2026
KAJ NY CONSTRUCTION INCGeneral Contractor107/08/2026
BMT PLUMBING&HEATING LLCPlumbing107/08/2026
BT'S PLUMBING AND HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010410/24/2022
Building Lifecycle
All (52)Filed (6)Permit Issued (5)Signed Off (3)Violation (4)Inspection (4)Special Inspection (30)
02/07/2023
Signed off — Alteration
Installation of new gas fired equipment and plumbing fixtures for the renovation and conversion of the existing one family dwelling into a two family dwellings. Filed in conjunction with ALT I application Q00648109
Q00697185-I1
12/04/2022
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Q00713277-I1
11/26/2022
Signed off — Alteration
Installation of a temporary construction fence, filed in conjunction with ALT I app#Q00648109-I1
Q00666209-I1
11/10/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/09/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/03/2022
Inspection — Pass-Final Fence Non-Directive 14
Pass
View inspection ↗
11/02/2022
Permit issued — Plumbing
Q00697185-I1-PL
10/27/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
10/27/2022
Special inspection requirement — Shutoff dampers
XIUCHENG LI
10/27/2022
Special inspection requirement — Fenestration air leakage
XIUCHENG LI
10/27/2022
Special inspection requirement — Permanent certificate
XIUCHENG LI
10/27/2022
Special inspection requirement — Fenestration areas
XIUCHENG LI
10/27/2022
Special inspection requirement — Insulation placement and R values
XIUCHENG LI
10/27/2022
Special inspection requirement — Mechanical Systems
XIUCHENG LI
10/27/2022
Special inspection requirement — Masonry
XIUCHENG LI
10/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
10/27/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
10/27/2022
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
10/27/2022
Special inspection requirement — Final
XIUCHENG LI
10/27/2022
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
10/27/2022
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
10/27/2022
Special inspection requirement — Lighting controls
XIUCHENG LI
10/27/2022
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
10/27/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
10/27/2022
Special inspection requirement — Air barrier - visual inspection
XIUCHENG LI
10/24/2022
Filed — Alteration CO
Existing one family dwelling to be vertically enlarged and converted into a two family dwellings. New drywall partitions ,and plumbing fixtures as per plans. .
Q00648109-P1
06/16/2022
Violation issued (ECB, closed)
Construction
06/16/2022
Violation issued (ECB, closed)
Site Safety
06/16/2022
Violation issued (ECB, closed)
Site Safety
06/07/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/17/2022
Special inspection requirement — Maintenance information
XIUCHENG LI
05/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/17/2022
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
05/17/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
05/17/2022
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
05/17/2022
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
05/16/2022
Filed — Alteration
Installation of new gas fired equipment and plumbing fixtures for the renovation and conversion of the existing one family dwelling into a two family dwellings. Filed in conjunction with ALT I application Q00648109
Q00697185-P1
05/13/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/13/2022
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
05/13/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
05/13/2022
Special inspection requirement — Maintenance information
XIUCHENG LI
05/13/2022
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
05/13/2022
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
04/07/2022
Permit issued — Sidewalk Shed
Q00713277-I1-SH
04/06/2022
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Q00713277-I1
04/01/2022
Permit issued — Plumbing
Q00697185-I1-PL
03/25/2022
Violation issued (ECB, closed)
Construction
03/21/2022
Filed — Alteration
Installation of new gas fired equipment and plumbing fixtures for the renovation and conversion of the existing one family dwelling into a two family dwellings. Filed in conjunction with ALT I application Q00648109
Q00697185-I1
01/28/2022
Permit issued — Construction Fence
Q00666209-I1-FN
01/27/2022
Permit issued — Structural
Q00648109-I1-GC-CX
01/24/2022
Filed — Alteration
Installation of a temporary construction fence, filed in conjunction with ALT I app#Q00648109-I1
Q00666209-I1
12/22/2021
Filed — Alteration CO
Existing one family dwelling to be vertically enlarged and converted into a two family dwellings. New drywall partitions ,and plumbing fixtures as per plans. .
Q00648109-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBMT PLUMBING&HEATING LLC11/02/2022
DOB NOWSidewalk ShedSigned-offKAJ NY CONSTRUCTION INC04/07/2022
DOB NOWPlumbingSigned-offBT'S PLUMBING AND HEATING04/01/2022
DOB NOWConstruction FenceSigned-offKAIETEUR CONSTRUCTION INC01/28/2022
DOB NOWStructuralPermit IssuedKAIETEUR CONSTRUCTION INC01/27/2022
1 project · most recent 10/24/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
10/24/2022Permit IssuedKAIETEUR CONSTRUCTION INCAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MXZ-4C36NA2 36,000 BTU · Condensing Unit ×8
Heating
Mitsubishi Electric MXZ-4C36NA2 36,000 BTU · Heat Pump Outdoor ×8
2 projects · most recent 04/19/2022
General Wiring
FiledStatusContractorScope
04/19/2022CompleteRICHARD NEU—
02/22/2022CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 10/24/2022
Masonry Wood
FiledStatusContractorScope
10/24/2022Permit IssuedKAIETEUR CONSTRUCTION INCMasonry, Wood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/10/2022Pass-Final CND-Occupancy InspectionPassView ↗
11/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/03/2022Pass-Final Fence Non-Directive 14PassView ↗
06/07/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
10/27/2022Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
10/27/2022Shutoff dampersXIUCHENG LIenergy_progress
10/27/2022Fenestration air leakageXIUCHENG LIenergy_progress
10/27/2022Permanent certificateXIUCHENG LIenergy_progress
10/27/2022Fenestration areasXIUCHENG LIenergy_progress
10/27/2022Insulation placement and R valuesXIUCHENG LIenergy_progress
10/27/2022Mechanical SystemsXIUCHENG LIspecial
10/27/2022MasonryXIUCHENG LIspecial
10/27/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
10/27/2022Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
10/27/2022Energy Code Compliance InspectionsXIUCHENG LIprogress
10/27/2022FinalXIUCHENG LIprogress
10/27/2022Fire-Resistance Rated ConstructionXIUCHENG LIprogress
10/27/2022HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
10/27/2022Lighting controlsXIUCHENG LIenergy_progress
10/27/2022HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
10/27/2022HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
10/27/2022Air barrier - visual inspectionXIUCHENG LIenergy_progress
05/17/2022Maintenance informationXIUCHENG LIenergy_progress
05/17/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
05/17/2022Energy Code Compliance InspectionsXIUCHENG LIprogress
05/17/2022HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
05/17/2022HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
05/17/2022HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
05/13/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
Latest 25 of 30.
▾Documents — 42 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/26/2026Q00666209-I1Request digital key ↗
08/26/2026Q00697185-P1Request digital key ↗
08/26/2026Q00697185-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00648109-P1Open ↗
08/13/2026Q00648109-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00648109-I1Open ↗
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature6
09/05/2026Q00697185-P1Open ↗
09/05/2026Q00697185-P1Open ↗
09/01/2026Q00648109-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/26/2026Q00666209-I1Open ↗
08/26/2026Q00697185-I1Open ↗
08/26/2026Q00697185-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/05/2026Q00697185-P1Open ↗
09/01/2026Q00648109-I1Open ↗
08/26/2026Q00697185-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/25/2026Q00648109-I1Open ↗
08/25/2026Q00648109-P1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00648109-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026Q00697185-I1Open ↗
08/26/2026Q00697185-P1Open ↗
08/25/2026Q00648109-I1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026Q00648109-I1Open ↗
08/13/2026Q00697185-I1Open ↗
▸Other Documents9
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00648109-P1Open ↗
08/13/2026Q00648109-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q00648109-P1Open ↗
08/13/2026Q00648109-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/25/2026Q00648109-P1Open ↗
08/25/2026Q00648109-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026Q00648109-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q00648109-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00648109-I1Open ↗