RoofUnder Construction3p · 1 filing
ArchitectureDMElectricalFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Protection and Mechanical Methods · Sprinklers · Standpipe · Structural
INSTALLATION OF TEMPORARY ROOF PROTECTION & OVERHEAD PROTECTION OVER ADJACENT PROPERTY AS PER PLANS. TEMPORARY PROTECTION SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
2 documents · 3 drawing sheets
Floor 401p · 1 filing · 3 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
Rem: 4wc,4lavs,2sks&1urinalon31fl. Rem:4wc,4lavs,1sk&1urinalon39fl. Rem:4wc,4lavs&1urinalon40fl.and cap all lines to source.
On file for this project
3 documents · 1 drawing sheet
Floor 391p · 1 filing · 3 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
Rem: 4wc,4lavs,2sks&1urinalon31fl. Rem:4wc,4lavs,1sk&1urinalon39fl. Rem:4wc,4lavs&1urinalon40fl.and cap all lines to source.
On file for this project
3 documents · 1 drawing sheet
Floor 38
Floor 376p · 1 filing · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REPLACE 4 WC, 5 LAVS & 1 URINAL ON EXISTING ROUGHING. INSTALL NEW 1 SINK, 1 DW, 1 WATER FILTER, 1 WATER PIPING & 1 SANITARY PIPING.
On file for this project
25 documents · 6 drawing sheets
Floor 365p · 4 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REPLACE: 4 LAVS, 4 WATER CLOSETS & 1 URINAL ON EXISTING ROUGHING. NEW: 1 SINK, 1 DISHWASHER, 1 FLOOR DRAIN, 1 WATER PIPING & 1 SANITARY PIPING AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
6 documents · 2 drawing sheets
INSTALL 52 NEW SPRINKLER HEADS AND PIPING AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
3 documents · 1 drawing sheet
RENOVATION OF THE INTERIOR OFFICE SPACE & CORRIDORS ON THE 36TH FLOOR AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
6 documents
Latest 3 of 4 filings on this floor.
Floor 35
Floor 34
Floor 336p · 1 filing · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE EXISTING DUCTWORK AND EXISTING CONDENSER WATER PIPING.
On file for this project
30 documents · 6 drawing sheets
Floor 321p · 1 filing · 5 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE 60 SPRINKLER HEADS AND INSTALL 60 NEW SPRINKLER HEADS AND PIPING.
On file for this project
5 documents · 1 drawing sheet
Floor 314p · 2 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE EXISTING DUCTWORK AND EXISTING CONDENSER WATER PIPING.
On file for this project
30 documents · 4 drawing sheets
Rem: 4wc,4lavs,2sks&1urinalon31fl. Rem:4wc,4lavs,1sk&1urinalon39fl. Rem:4wc,4lavs&1urinalon40fl.and cap all lines to source.
On file for this project
3 documents · 1 drawing sheet
Floor 30
Floor 29
Floor 28
Floor 27
Floor 26
Floor 25
Floor 24
Floor 234p · 1 filing · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE EXISTING DUCTWORK AND EXISTING CONDENSER WATER PIPING.
On file for this project
30 documents · 4 drawing sheets
Floor 222p · 1 filing · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE EXISTING DUCTWORK AND EXISTING CONDENSER WATER PIPING.
On file for this project
30 documents · 2 drawing sheets
Floor 212p · 2 filings · 10 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
INSTALL 69 NEW SPRINKLER HEADS AND PIPING.
On file for this project
6 documents · 1 drawing sheet
MODIFY DUCTWORK
On file for this project
4 documents · 1 drawing sheet
Floor 20
Floor 19
Floor 186p · 3 filings · 16 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
MODIFY DUCTWORK AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
4 documents · 2 drawing sheets
REPLACE 5 LAVS, 4 WC & 1 URINAL ON EXISTING ROUGHING. INSTALL NEW 1 SINK, 1 DISHWASHER, 1 WATER PIPING & 1 SANITARY PIPING AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
3 documents · 3 drawing sheets
REMOVE 19 SPRINKLER HEADS & INSTALL 79 NEW SPRINKLER HEADS AND PIPING AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
9 documents · 1 drawing sheet
Floor 17
Floor 16
Floor 15
Floor 145p · 3 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE 1 URINAL, 4 WATER CLOSETS, 4 LAVS, 1 PANTRY SINK & 1 DISHWASHER. INSTALL 2 NEW PANTRY SINKS, 2 HOT WATER HEATERS (NON GAS), 2 DISHWASHERS, 1 URINAL, 4 LAVS & 4 WATER CLOSETS.
On file for this project
3 documents · 1 drawing sheet
REMOVE 53 SPRINKLER HEADS AND INSTALL 66 SPRINKLER HEADS AND PIPING.
On file for this project
5 documents · 2 drawing sheets
MODIFY DUCTWORK
On file for this project
13 documents · 2 drawing sheets
Floor 13
Floor 123p · 2 filings · 15 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE: 1 SINK AND CAP LINES AT SOURCE. REPLACE: 4 LAVS, 4 WC & 1 URINAL ON EXISTING ROUGHING. NEW: 1 SINK, 1 DISHWASHER, 1 FLOOR DRAIN, 1 WATER PIPING & 1 SANITARY PIPING.
On file for this project
3 documents · 1 drawing sheet
MODIFY DUCTWORK.
On file for this project
12 documents · 2 drawing sheets
Floor 11
Floor 10
Floor 9
Floor 8
Floor 715p · 5 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REMOVE 1 SINK & 1 WATER COOLER AND CAP LINES AT SOURCE. INSTALL NEW 3 SINKS, 1 DISHWASHER, 1 WC, 1 LAV, 1 WATER PIPING & 1 SANITARY PIPING.
On file for this project
3 documents · 3 drawing sheets
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents · 4 drawing sheets
MODIFY DUCTWORK AND INSTALL 1 NEW AC UNIT.
On file for this project
4 documents · 2 drawing sheets
Latest 3 of 5 filings on this floor.
Floor 61 filing · 11 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
Floor 51 filing · 11 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
Floor 41 filing · 11 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
Floor 31 filing · 11 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
Floor 21 filing · 11 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
Floor 15p · 6 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
RENOVATION OF LOBBY, ELEVATORS AND PLAZA INCLUDING EXTERIOR WALL, REVOLVING DOORS, CEILINGS, SECURITY DESK, FRONT DESK & TURNSTILES ALONG WITH PLAZA AND ARCADE PIT IMPROVEMENTS AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
4 documents · 1 drawing sheet
REM EXISTING PIPING ON CEL&1ST FLRS&CUT LINES AT SOURCE. NEW:1WATER PIPING&1SANITARY PIPING IN CEL. NEW:8 FL DRAINS,2 SKS, 1WATERPIPING,1SANITARYPIPING,1STORMPIPING&1 RPZ SECONDARY ON 1ST FL &. NEW: CONNECT PIPING TO EXISTING ON 1ST FL MECH LEVEL.
On file for this project
9 documents · 3 drawing sheets
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
Latest 3 of 6 filings on this floor.
Mezzanine2p · 3 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Standpipe · Structural
REM EXISTING PIPING ON CEL&1ST FLRS&CUT LINES AT SOURCE. NEW:1WATER PIPING&1SANITARY PIPING IN CEL. NEW:8 FL DRAINS,2 SKS, 1WATERPIPING,1SANITARYPIPING,1STORMPIPING&1 RPZ SECONDARY ON 1ST FL &. NEW: CONNECT PIPING TO EXISTING ON 1ST FL MECH LEVEL.
On file for this project
9 documents · 1 drawing sheet
CEL:REM EXIST PIPING, REL: 1 SP HD&PIPING-NEW: 2 NEW SP HEADS AND PIPING. 1ST FL: NEW: 1 DRY PIPING&5 DRY SP HEADS,86 WET SP HEADS & PIPING, 1 SP PIPING & 1 SD PIPING. 1ST FL MECH LEVEL: NEW: 1 DRY PIPING, 2 WET SP HEADS & PIPING. REL: 2 SP HEADS & PIPING
On file for this project
12 documents · 1 drawing sheet
Project M00384852Permit Issued · 11/18/2020
REMOVE & INSTALL PLUMBING FIXTURES AND RELATED PIPING. INSTALL NEW SPRINKLER HEADS AND ASSOCIATED PIPING AS SHOWN ON DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Cellar6p · 6 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
REM EXISTING PIPING ON CEL&1ST FLRS&CUT LINES AT SOURCE. NEW:1WATER PIPING&1SANITARY PIPING IN CEL. NEW:8 FL DRAINS,2 SKS, 1WATERPIPING,1SANITARYPIPING,1STORMPIPING&1 RPZ SECONDARY ON 1ST FL &. NEW: CONNECT PIPING TO EXISTING ON 1ST FL MECH LEVEL.
On file for this project
9 documents · 2 drawing sheets
FILING HEREWITH TO INCREASE # OF PERSONS, ADD ROOF TERRACE ACCESSORY USE TO OFFICES, MINOR PARTITION WORK.
On file for this project
11 documents
REMOVAL OF EXISTING DISTRIBUTION SYSTEM AND INSTALLATION OF NEW DISTRIBUTION SYSTEM ALONG WITH AIR CONDITIONING UNITS & PERIMETER TRENCH FANS AS SHOWN ON DRAWINGS FILED HEREWITH.
On file for this project
24 documents · 2 drawing sheets
Latest 3 of 6 filings on this floor.