← Back
Two family converted from one family
84 86 STREET
BROOKLYN · BIN 3153352
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R3-1Zoning
1,496 sfGross Floor Area
2Units
Two family converted from one family · 3,333 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Floor 25p · 2 filings · 9 docs
Floor 16p · 2 filings · 9 docs
Cellar5p · 2 filings · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/16/2021$1.3M—DESPINA KOTSIS TRUST → Private party$887/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAMANN ENGINEERING, PLLC403/17/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BIG ORANGE EXPEDITING803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMERICAN STANDARD P&H CORORP.Plumbing907/08/2026
DARIUSZ GRYGLEWSKIElectrical503/21/2026
FSM ELECTRICAL CORPORATIO 004264General Contractor403/22/2026
COOLQUEST MECHANICAL INCGeneral Contractor303/21/2026
BIG ORANGE SAFETY FIRSTGeneral Contractor207/08/2026
SUPERB PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HAMANN ENGINEERING, PLLC4949203/17/2022
Nothing on file for this building.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedBIG ORANGE SAFETY FIRST08/09/2022
DOB NOWMechanical SystemsPermit IssuedCOOLQUEST MECHANICAL INC03/23/2022
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.09/24/2021
DOB NOWPlumbingSigned-offSUPERB PLUMBING & HEATING07/20/2021
DOB NOWGeneral ConstructionPermit IssuedBIG ORANGE SAFETY FIRST06/23/2021
1 project · most recent 03/17/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/17/2022Permit IssuedCOOLQUEST MECHANICAL INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-3C30NA 30,000 BTU · Heat Pump Outdoor ×1
MXZ-5C42NA 42,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 03/21/2025
General Wiring
FiledStatusContractorScope
03/21/2025CompleteFSM ELECTRICAL CORPORATIOGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
10/19/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/17/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/10/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/07/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/10/2021Pass-Final PL - UndergroundPassView ↗
11/04/2021Fail-Final PL - UndergroundFailView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
03/17/2022HVAC-R and service water piping design and insulationCARL HAMANNenergy_progress
03/17/2022HVAC-R and service water heating system controlsCARL HAMANNenergy_progress
03/17/2022HVAC-R and service water heating equipmentCARL HAMANNenergy_progress
03/17/2022Energy Code Compliance InspectionsCARL HAMANNprogress
03/17/2022Maintenance informationCARL HAMANNenergy_progress
03/16/2022FinalCARL HAMANNprogress
03/16/2022Mechanical SystemsCARL HAMANNspecial
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/01/2026B00534219-I1Request digital key ↗
09/01/2026B00534234-I1Request digital key ↗
09/01/2026B00534234-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B00534234-I1Open ↗
08/13/2026B00534234-P1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00534219-I1Open ↗
09/01/2026B00534234-I1Open ↗
09/01/2026B00534234-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026B00700334-I1Open ↗
08/26/2026B00700334-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B00700334-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/01/2026B00534219-I1Open ↗
09/01/2026B00534234-P1Open ↗
09/01/2026B00534234-I1Open ↗
Showing 3 of 4 on file for this type