← Back
Multi-story department store
85 BRICKTOWN WAY
STATEN ISLAND · BIN 5170014
💬 Discuss this project
2006Year Built
1Stories
K3Building Class
M1-1Zoning
106,672 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Multi-story department store · Owner of record: CHARLESTON HD-BJ, LLC · 404,214 sf lot · 0.26 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Roof8p · 3 filings · 20 docs
Floor 125p · 1 filing · 20 docs
Mezzanine29p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
41 GREAT JONES HOLDING4307/08/2026
CHARLESTON ENTERPRISES6407/08/2026
DGC CAPITAL CONTRACTING C103/22/2026
APPLEBEE'S203/21/2026
BLUMENFELD DEVELOPMENT GROUP203/21/2026
APPLEBEES203/21/2026
DIMENSION CONSTRUCTION203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GERALD J. CALIENDO R.A., P.C.1803/21/2026
LOUIS STRIAR1603/21/2026
JS ARCHITECTURE DESIGN203/21/2026
NEW YORK ENGINEERING ASSOCIATES P403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SIGNSTAR NYCScaffold807/08/2026
DGC CAPITAL CONTRACTING CORPGeneral Contractor707/08/2026
DENAIR HVAC INCGeneral Contractor107/08/2026
NOVA ELECTRIC LLCElectrical103/22/2026
A & M WARSHAW PLBG & HTGPlumbing107/08/2026
BLUEWATER PLBG& HTG INCPlumbing107/08/2026
GULLY HEATING & COOLING IGeneral Contractor107/08/2026
PLUMBING WORKS CORPFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CROSSCHECK INSPECTION SER5441603/20/2026
NEW YORK ENGINEERING ASSO851207/31/2024
LL ENGINEERING PC1618105/03/2022
Building Lifecycle
All (139)Filed (29)Permit Issued (19)Signed Off (19)Violation (19)Inspection (13)Objection (10)Special Inspection (30)
07/31/2026
Objection resolved — Addressed
07/27/2026
Objection resolved — Addressed
07/27/2026
Objection resolved — Addressed
07/27/2026
Objection resolved — Addressed
07/16/2026
Objection raised — Other
07/16/2026
Objection raised — Other
07/16/2026
Objection raised — Other
07/16/2026
Objection raised — Other
07/09/2026
Filed — Alteration
S01425855-I1
07/02/2026
Special inspection requirement — Air barrier - visual inspection
07/02/2026
Special inspection requirement — Final
07/02/2026
Special inspection requirement — Energy Code Compliance Inspections
07/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
03/24/2026
Special inspection requirement — Energy Code Compliance Inspections
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Lighting controls
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Interior lighting power
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Air barrier - visual inspection
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Insulation placement and R values
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Fenestration air leakage
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
03/24/2026
Special inspection requirement — Fenestration areas
EUGENE BIFULCO
03/20/2026
Filed — Alteration CO
Change of occupancy for new single mercantile BJs Wholesale Club occupancy of previous three (3) tenant occupied building. Work to include new windows and doors as per plans and increasing the height of the loading dock doors and obtain an amended CO.
S01015761-P3
02/26/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Interior lighting power
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Fenestration air leakage
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Lighting controls
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Fenestration areas
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Air barrier - visual inspection
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Energy Code Compliance Inspections
EUGENE BIFULCO
02/26/2026
Special inspection requirement — Insulation placement and R values
EUGENE BIFULCO
01/16/2026
Filed — Alteration CO
Change of occupancy for new single mercantile BJs Wholesale Club occupancy of previous three (3) tenant occupied building. Work to include new windows and doors as per plans and increasing the height of the loading dock doors and obtain an amended CO.
S01015761-P2
09/15/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
EUGENE BIFULCO
09/15/2025
Special inspection requirement — Energy Code Compliance Inspections
EUGENE BIFULCO
09/15/2025
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
09/15/2025
Special inspection requirement — Air barrier - visual inspection
EUGENE BIFULCO
09/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
08/13/2025
Violation issued (FDNY_NOV, closed)
08/12/2025
Violation issued (FDNY_NOV, closed)
08/12/2025
Violation issued (FDNY_NOV, closed)
07/07/2025
Signed off — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-S4
06/17/2025
Filed — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-P6
05/29/2025
Signed off — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-S3
04/21/2025
Signed off — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-S2
04/21/2025
Signed off — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-S1
03/13/2025
Signed off — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-I1
03/11/2025
Filed — Alteration CO
Change of occupancy for new single mercantile BJs Wholesale Club occupancy of previous three (3) tenant occupied building. Work to include new windows and doors as per plans and increasing the height of the loading dock doors and obtain an amended CO.
S01015761-P1
02/14/2025
Signed off — Alteration
INSTALL TWO DAY TANKS FOR TWO EMERGENCY DIESEL GENERATORS.
S01073853-I1
02/14/2025
Signed off — Alteration
INSTALL TWO DAY TANKS FOR TWO EMERGENCY DIESEL GENERATORS.
S01073853-S1
01/30/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/08/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2025
Signed off — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-S6
11/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/27/2024
Filed — Alteration
MECHANICAL WORKTYPE FILED SUBSEQUENTLY TO GC APPLICATION IN ORDER TO INSTALL NEW MECHANICAL EQUIPMENT ON THE GROUND FLOOR AND ROOF, INCLUDING COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM AND FIRE SUPPRESSION SYSTEM. NO CHANGE TO USE OCCUPANCY OR EGRESS
S01022806-P5
11/26/2024
Signed off — Alteration
S01070157-I1
Latest 60 of 139 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDGC CAPITAL CONTRACTING CORP09/30/2024
DOB NOWMechanical SystemsSigned-offDENAIR HVAC INC08/09/2024
DOB NOWMechanical SystemsSigned-offDGC CAPITAL CONTRACTING CORP08/06/2024
DOB NOWBoiler EquipmentSigned-offJACK PICCINI, INC08/02/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/30/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/30/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/29/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/29/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/29/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/29/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/29/2024
DOB NOWSignSigned-offSIGNSTAR NYC07/29/2024
DOB NOWPlumbingSigned-offBLUEWATER PLBG& HTG INC06/14/2024
DOB NOWStructuralSigned-offDGC CAPITAL CONTRACTING CORP06/12/2024
DOB NOWPlumbingSigned-offA & M WARSHAW PLBG & HTG05/30/2024
DOB NOWGeneral ConstructionSigned-offDGC CAPITAL CONTRACTING CORP05/24/2024
DOB NOWSprinklersSigned-offBLUEWATER P&H, INC04/24/2024
DOB NOWGeneral ConstructionSigned-offDGC CAPITAL CONTRACTING CORP04/10/2024
DOB NOWMechanical SystemsSigned-offGULLY HEATING COOLING I06/08/2022
BISMHISSUEDLANE REFRIGERATION CO.,IN08/28/2019
BISFPISSUEDRELIABLE FIRE PROT. INC09/12/2016
BISMHISSUEDDWORKIN CONSTRUCTION CORP.11/13/2013
BISFPISSUEDRELIABLE FIRE PROT. INC09/13/2013
BISPLISSUEDMPC PLUMBING & HEATING INC07/26/2013
BISOTISSUEDDWORKIN CONSTRUCTION CORP.07/23/2013
BISMHISSUEDDWORKIN CONSTRUCTION CORP.07/23/2013
BISOTISSUEDSOLAR ENERGY SYSTEMS INC04/09/2013
BISOTISSUEDSOLAR ENERGY SYSTEMS INC10/23/2012
BISMHISSUEDLANE REFRIGERATION CO.,IN09/19/2008
BIS—ISSUEDNATIONAL MAINTENANCE INC07/24/2006
BIS—ISSUEDNORTH SHORE NEON SIGN CO INC07/18/2006
BIS—ISSUEDNORTH SHORE NEON SIGN CO INC07/18/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC06/06/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC05/17/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC05/17/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC05/17/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC05/17/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC05/17/2006
BISPLISSUEDDUO PLUMBING & HTG CORP.05/11/2006
BISSPISSUEDTPC II CONTRACTORS INC05/10/2006
+ 9 more permits on file
4 jobs · most recent 04/15/2025
General Wiring
FiledStatusContractorScope
04/15/2025CompleteNOVA ELECTRIC LLCGeneral Wiring
09/19/2024CompleteNOVA ELECTRIC LLC1 meters
04/09/2024CompleteNOVA ELECTRIC LLC—
10/06/2023CompleteCATELLO ELEC'L CONT., INCGeneral Wiring
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
01/30/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/29/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/29/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/26/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/03/2024Pass-Final Boiler Equipment InspectionPassView ↗
09/27/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/13/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/19/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/29/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/22/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/20/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 95
DateRequirementInspectorRole
07/02/2026Fire-Resistant Penetrations and Joints—special
07/02/2026Air barrier - visual inspection—energy_progress
07/02/2026Final—progress
07/02/2026Energy Code Compliance Inspections—progress
07/02/2026Structural Stability – Alterations of existing buildings—special
03/24/2026Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
03/24/2026Fenestration air leakageEUGENE BIFULCOenergy_progress
03/24/2026Interior lighting powerEUGENE BIFULCOenergy_progress
03/24/2026Insulation placement and R valuesEUGENE BIFULCOenergy_progress
03/24/2026Fenestration and door U-factor and product ratingsEUGENE BIFULCOenergy_progress
03/24/2026Fenestration areasEUGENE BIFULCOenergy_progress
03/24/2026Air barrier - visual inspectionEUGENE BIFULCOenergy_progress
03/24/2026Lighting controlsEUGENE BIFULCOenergy_progress
03/24/2026Energy Code Compliance InspectionsEUGENE BIFULCOprogress
03/24/2026Post-installed AnchorsEUGENE BIFULCOspecial
02/26/2026Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
02/26/2026Insulation placement and R valuesEUGENE BIFULCOenergy_progress
02/26/2026Fenestration areasEUGENE BIFULCOenergy_progress
02/26/2026Air barrier - visual inspectionEUGENE BIFULCOenergy_progress
02/26/2026Fenestration air leakageEUGENE BIFULCOenergy_progress
02/26/2026Fenestration and door U-factor and product ratingsEUGENE BIFULCOenergy_progress
02/26/2026Lighting controlsEUGENE BIFULCOenergy_progress
02/26/2026Interior lighting powerEUGENE BIFULCOenergy_progress
02/26/2026Energy Code Compliance InspectionsEUGENE BIFULCOprogress
02/26/2026Post-installed AnchorsEUGENE BIFULCOspecial
Latest 25 of 95.
▾Documents — 267 on file (BIS + DOB NOW)
▸Plans & Drawings29
▸DOB NOWPlans/Sketch29
08/24/2026S00728705-I1Request digital key ↗
08/21/2026S01014758-S1Request digital key ↗
08/21/2026S01014758-I1Request digital key ↗
Showing 3 of 29 on file for this type
▸Applications & Permits25
▸BISPLAN / WORK APPROVAL APPLICATION14
01/29/2021520378840Open ↗
04/22/2019520378840Open ↗
04/01/2016520222250Open ↗
Showing 3 of 14 on file for this type
▸BISWORK PERMIT APPLICATION11
08/29/2019520378840Open ↗
09/13/2016520222250Open ↗
11/21/2013520147010Open ↗
Showing 3 of 11 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S01015761-I1Open ↗
▸Seals & Professional Certifications107
▸DOB NOWProgress Inspector Seal & Signature30
09/02/2026S01022806-P3Open ↗
09/02/2026S01022806-P3Open ↗
09/01/2026S01022806-S3Open ↗
Showing 3 of 30 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature29
08/21/2026S01014758-S1Open ↗
08/21/2026S01014758-I1Open ↗
08/21/2026S01022806-P4Open ↗
Showing 3 of 29 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION24
04/22/2019520378840Open ↗
03/27/2017520222250Open ↗
09/13/2016520222250Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/23/2026S01073853-I1Open ↗
09/02/2026S01022806-P3Open ↗
09/01/2026S01022806-S3Open ↗
Showing 3 of 15 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
07/19/2013520147010Open ↗
07/19/2013520147010Open ↗
09/09/2009520019532Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
07/19/2013520147010Open ↗
09/09/2009520019532Open ↗
05/08/2009520003763Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment14
▸BISEQUIPMENT USE PERMITS3
07/02/2021520378840Open ↗
06/08/2009520003763Open ↗
11/20/2008510049289Open ↗
▸BISSCHEDULE B - PLUMBING3
08/13/2013520149303Open ↗
07/19/2013520147010Open ↗
09/09/2009520019532Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA3
03/02/2016520057107Open ↗
01/12/2016520057107Open ↗
01/27/2014520149303Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT3
07/02/2021520378840Open ↗
06/08/2009520003763Open ↗
11/20/2008510049289Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
09/18/2013520147010Open ↗
09/11/2013520147010Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist4
08/13/2026S01015761-P2Open ↗
08/13/2026S01015761-P1Open ↗
08/13/2026S01015761-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStreet Tree Sign Off1
08/13/2026S01015761-I1Open ↗
▸Environmental & Asbestos8
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER5
08/27/2012520079806Open ↗
01/24/2011520057107Open ↗
09/09/2009520019532Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
04/22/2019520378840Open ↗
04/01/2016520222250Open ↗
08/13/2013520149303Open ↗
▸Energy Compliance15
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
04/22/2019520378840Open ↗
10/28/2013520147010Open ↗
07/19/2013520147010Open ↗
▸BISAS-BUILT ENERGY ANALYSIS3
03/03/2021520378840Open ↗
10/28/2013520147010Open ↗
09/03/2013520079806Open ↗
▸BISTR8: Energy Code Progress Inspections2
09/03/2013520079806Open ↗
08/27/2012520079806Open ↗
▸DOB NOWPreliminary Commissioning Report Certification2
08/13/2026S01022806-S2Open ↗
08/13/2026S01022806-S3Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
09/03/2013520079806Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION (PTA4)1
09/17/2013520079806Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
03/03/2021520378840Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
08/27/2012520079806Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026S00728705-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/03/2021520378840Open ↗
▸Approvals, Objections & Sign-offs24
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST13
03/03/2021520378840Open ↗
10/23/2017500775164Open ↗
10/12/2017500775164Open ↗
Showing 3 of 13 on file for this type
▸BISADMINISTRATIVE OBJECTIONS8
04/22/2019520378840Open ↗
04/01/2016520222250Open ↗
08/13/2013520149303Open ↗
Showing 3 of 8 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
03/27/2017520222250Open ↗
09/03/2013520079806Open ↗
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
09/13/2013520079806Open ↗
▸Cost, Insurance & Ownership17
▸BISCOST AFFIDAVIT17
03/03/2021520378840Open ↗
04/22/2019520378840Open ↗
03/27/2017520222250Open ↗
Showing 3 of 17 on file for this type
▸Filing & Intake Forms11
▸BISEFILING COVER SHEET6
04/22/2019520378840Open ↗
04/01/2016520222250Open ↗
08/13/2013520149303Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION2
09/03/2013520079806Open ↗
08/27/2012520079806Open ↗
▸BISBOROUGH INTAKE FORM2
10/23/2017500775164Open ↗
10/12/2017500775164Open ↗
▸BISeFiling Job Application Cover Sheet1
09/26/2012520079806Open ↗
▸Other Documents10
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION4
09/13/2013520079806Open ↗
09/13/2013520079806Open ↗
07/20/2011520057107Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/17/2026S01015761-P2Open ↗
08/17/2026S01015761-P3Open ↗
08/17/2026S01015761-I1Open ↗
Showing 3 of 4 on file for this type
▸BISFIRE SUPP ANSUL APPROVL: FD-FSS1
03/27/2017520222250Open ↗
▸DOB NOWFinal Survey1
08/13/2026S01015761-I1Open ↗