← Back
BuildNYC
Limited service hotel, often national chain
859 7TH AVENUE
MANHATTAN · BIN 1083722
💬 Discuss this project
1911Year Built
26Stories
H3Building Class
C6-6Zoning
207,700 sfGross Floor Area
6Units
LL97 CoveredRent Stabilized14 Active Violations 13 unresolved · 1 paperwork only 1 old, status unconfirmed ▸FISP: UNSAFE
Limited service hotel, often national chain · Owner of record: Wellington Property Owner · 22,240 sf lot · 9.34 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Whole building & multi-floor projectsExtell DevelopmentUnder Construction4 filings
RoofT-MobileUnder Construction1p · 3 filings
Floor 18Extell DevelopmentUnder Construction2p · 1 filing
Floor 17
Floor 16
Floor 15
Floor 14
Floor 13
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 2
Floor 1
CellarExtell DevelopmentUnder Construction2p · 1 filing
Sub-BasementT-Mobile1 filing · 3 docs
Site & exteriorExtell DevelopmentUnder Construction5 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Extell Development3709/25/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KZ Engineering1004/20/2026
Ancora Engineering1004/02/2026
Paul Perdek, Prof. Engineering101/20/2026
Prudigm Engineering106/30/2025
A Saxon Design Group103/09/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Synergy Building Consultants703/21/2026
Expedite Dem1403/21/2026
AE Design Solution203/21/2026
NYC Approvals203/21/2026
CCM Services Group103/21/2026
Domani Consulting403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Arsenal ScaffoldScaffold1409/03/2026
Vema GroupScaffold803/21/2026
Titan Industrial ServiceScaffold509/25/2026
Himalaya TowersGeneral Contractor407/08/2026
Titan Industrial ServiceGeneral Contractor307/08/2026
Welkin EnterprisesPlumbing207/08/2026
Northeast Specialist GroupGeneral Contractor203/21/2026
Associated Electric Cont of NElectrical203/21/2026
Elmac ElectricElectrical103/21/2026
Johnson RaymondElectrical103/21/2026
Borowide Elect'l ContractorsElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KZ Engineering4665604/20/2026
Ancora Engineering6818704/02/2026
R Marsac Consulting329103/09/2022
Building Lifecycle
All (157)Filed (23)Permit Issued (29)Signed Off (1)Facade (FISP) (15)Violation (57)Inspection (3)Objection (8)Special Inspection (21)
09/24/2026
Permit issued — Protection and Mechanical Methods
M01177085-S3-PMM
09/23/2026
Permit issued — Protection and Mechanical Methods
M01177085-S1-PMM
09/02/2026
Permit issued — Construction Fence
M01248739-I1-SF
09/01/2026
Permit issued — Supported Scaffold
M01248739-I1-FN
09/01/2026
Permit issued — Supported Scaffold
M01248739-I1-SH
08/31/2026
Permit issued — Supported Scaffold
M01249829-I1-SF
08/31/2026
Permit issued — Protection and Mechanical Methods
M01257145-I1-PMM
06/04/2026
Cycle 10 facade report submitted
06/03/2026
Cycle 10 facade inspection completed
06/03/2026
Cycle 10 facade report signed — UNSAFE
04/29/2026
Violation issued (HPD, open)
A
04/22/2026
Permit issued — Full Demolition
M01177085-I1-FD
04/20/2026
Filed — Alteration
Installation of temporary construction fence, supported scaffold, and heavy duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01248739-P1
04/20/2026
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
04/09/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Karol Zdancewicz
04/07/2026
Filed — Alteration
Installation of temporary needle beam per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01319540-P1
04/06/2026
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
04/03/2026
Filed — Alteration
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01249829-P1
04/03/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
Gregory Moormann
04/03/2026
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
04/03/2026
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
04/02/2026
Filed — Full Demolition
full demolition of 26 story structure using hand held and mechanical means to assist.
M01177085-P4
04/02/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
Gregory Moormann
03/31/2026
Permit issued — Sidewalk Shed
M01248739-I1-SH
03/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Karol Zdancewicz
03/27/2026
Violation issued (ECB, closed)
Construction
03/27/2026
Violation issued (ECB, closed)
Construction
03/27/2026
Violation issued (ECB, closed)
Construction
03/27/2026
Violation issued (ECB, closed)
Construction
03/27/2026
Violation issued (ECB, closed)
Site Safety
03/10/2026
Permit issued — Full Demolition
M01177085-I1-FD
03/09/2026
Filed — Full Demolition
full demolition of 26 story structure using hand held and mechanical means to assist.
M01177085-P3
03/07/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
Gregory Moormann
02/27/2026
Cycle 10 facade report submitted
02/27/2026
Cycle 10 facade report signed — UNSAFE
02/26/2026
Cycle 10 facade inspection completed
02/11/2026
Permit issued — Protection and Mechanical Methods
M01177085-S3-PMM
02/09/2026
Permit issued — Protection and Mechanical Methods
M01177085-S1-PMM
02/05/2026
Filed — Full Demolition
full demolition of 26 story structure using hand held and mechanical means to assist.
M01177085-P2
01/26/2026
Permit issued — Construction Fence
M01348217-I1-FN
01/24/2026
Objection resolved — Addressed
01/20/2026
Filed — Alteration
INSTALLATION OF TEMPORARY PLYWOOD ENCLOSURE AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01348217-I1
01/15/2026
Objection raised — Structural
12/26/2025
Special inspection requirement — Post-installed Anchors
Gregory Moormann
12/26/2025
Special inspection requirement — Structural Steel - Details
Gregory Moormann
12/26/2025
Special inspection requirement — Structural Steel - High Strength Bolting
Gregory Moormann
12/26/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Gregory Moormann
12/23/2025
Filed — Alteration
Installation of 7,100# temporary single car personnel hoist in conjunction with FD# M01177085, per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01257145-P1
12/23/2025
Filed — Full Demolition
full demolition of 26 story structure using hand held and mechanical means to assist.
M01177085-P1
12/19/2025
Permit issued — Protection and Mechanical Methods
M01319540-I1-PMM
12/19/2025
Special inspection requirement — Structural Stability – Alterations of existing Buildings
12/18/2025
Filed — Alteration
Installation of temporary needle beam per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01319540-I1
12/15/2025
Special inspection requirement — Structural Steel - High Strength Bolting
Gregory Moormann
12/15/2025
Special inspection requirement — Post-installed Anchors
Gregory Moormann
12/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Gregory Moormann
12/15/2025
Special inspection requirement — Structural Steel - Details
Gregory Moormann
11/17/2025
Violation issued (HPD, open)
I
09/26/2025
Permit issued — Supported Scaffold
M01249829-I1-SF
09/26/2025
Permit issued — Sidewalk Shed
M01248739-I1-FN
09/26/2025
Permit issued — Sidewalk Shed
M01248739-I1-SF
Latest 60 of 157 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWProtection and Mechanical MethodsPermit IssuedTitan Industrial Service09/24/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedTitan Industrial Service09/23/2026
DOB NOWConstruction FencePermit IssuedArsenal Scaffold09/02/2026
DOB NOWSupported ScaffoldPermit IssuedArsenal Scaffold09/01/2026
DOB NOWSupported ScaffoldPermit IssuedArsenal Scaffold09/01/2026
DOB NOWSupported ScaffoldPermit IssuedArsenal Scaffold08/31/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedArsenal Scaffold08/31/2026
DOB NOWFull DemolitionPermit IssuedTitan Industrial Service04/22/2026
DOB NOWSidewalk ShedPermit IssuedArsenal Scaffold03/31/2026
DOB NOWFull DemolitionPermit IssuedTitan Industrial Service03/10/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedTitan Industrial Service02/11/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedTitan Industrial Service02/09/2026
DOB NOWConstruction FencePermit IssuedTitan Industrial Service01/26/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedArsenal Scaffold12/19/2025
DOB NOWSupported ScaffoldPermit IssuedArsenal Scaffold09/26/2025
DOB NOWSidewalk ShedPermit IssuedArsenal Scaffold09/26/2025
DOB NOWSidewalk ShedPermit IssuedArsenal Scaffold09/26/2025
DOB NOWSupported ScaffoldPermit IssuedArsenal Scaffold09/26/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedArsenal Scaffold09/25/2025
DOB NOWStandpipePermit IssuedWelkin Enterprises08/13/2025
DOB NOWGeneral ConstructionPermit IssuedTitan Industrial Service08/12/2025
DOB NOWStandpipePermit IssuedWelkin Enterprises07/09/2025
DOB NOWGeneral ConstructionPermit IssuedNortheast Specialist Group05/29/2024
DOB NOWAntennaSigned-offHimalaya Towers01/19/2023
DOB NOWAntennaSigned-offHimalaya Towers09/08/2022
DOB NOWSupported ScaffoldPermit IssuedVema Group11/13/2019
DOB NOWSidewalk ShedPermit IssuedVema Group11/13/2019
DOB NOWSidewalk ShedPermit IssuedVema Group11/13/2018
DOB NOWSidewalk ShedPermit IssuedVema Group09/18/2018
BISOTISSUEDManhattan Construction06/23/2020
BISOTISSUEDManhattan Construction06/23/2020
BISOTISSUEDVema Group04/15/2020
BISOTISSUEDManhattan Construction07/10/2019
BISMHISSUEDRight Temp Mechanical06/13/2019
BISOTISSUEDVema Group06/12/2019
BISOTISSUEDManhattan Construction03/06/2019
BISOTISSUEDManhattan Construction03/06/2019
BISMHISSUEDRight Temp Mechanical05/29/2018
BISOTISSUEDManhattan Construction05/11/2018
BISOTISSUEDManhattan Construction05/04/2018
+ 15 more permits on file
1 project · most recent 06/30/2025
FiledStatusContractorScope
06/30/2025——1 outlets
1 project · most recent 06/30/2025
FiledStatusContractorScope
06/30/2025Permit IssuedWelkin Enterprises—
4 projects · most recent 08/28/2025
FiledStatusContractorScope
08/28/2025Permit IssuedSolas Electrical—
08/28/2025Permit IssuedSolas Electrical—
07/23/2021CompleteTriboro Electrical Contracting Co—
08/16/2018Permit IssuedBorowide Elect'l Contractors—
2 projects · most recent 01/20/2026
FiledStatusContractorScope
01/20/2026Permit IssuedTitan Industrial Service1 scope_items
06/26/2025Permit IssuedNortheast Specialist Group1 scope_items
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/28/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/28/2025Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)CertifiedView ↗
08/28/2025Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
04/20/2026Post-installed AnchorsKarol Zdancewiczspecial
04/09/2026Structural Stability – Alterations of existing buildingsKarol Zdancewiczspecial
04/06/2026Post-installed AnchorsKarol Zdancewiczspecial
04/03/2026Structural Stability – Alterations of existing BuildingsGregory Moormannspecial
04/03/2026Post-installed AnchorsKarol Zdancewiczspecial
04/03/2026Post-installed AnchorsKarol Zdancewiczspecial
04/02/2026Structural Stability – Alterations of existing BuildingsGregory Moormannspecial
03/30/2026Structural Stability – Alterations of existing buildingsKarol Zdancewiczspecial
03/07/2026Structural Stability – Alterations of existing BuildingsGregory Moormannspecial
12/26/2025Post-installed AnchorsGregory Moormannspecial
12/26/2025Structural Steel - DetailsGregory Moormannspecial
12/26/2025Structural Steel - High Strength BoltingGregory Moormannspecial
12/26/2025Structural Stability – Alterations of existing buildingsGregory Moormannspecial
12/19/2025Structural Stability – Alterations of existing Buildings—special
12/15/2025Structural Steel - High Strength BoltingGregory Moormannspecial
12/15/2025Post-installed AnchorsGregory Moormannspecial
12/15/2025Structural Stability – Alterations of existing buildingsGregory Moormannspecial
12/15/2025Structural Steel - DetailsGregory Moormannspecial
06/27/2025FinalGregory Moormannprogress
06/17/2025Standpipe SystemsGregory Moormannspecial
05/22/2025FinalGregory Moormannprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
T-MobileTelecom siteSub-basement, Roof
Project M00651899 Alteration · LOC Issued · 03/09/2022
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 254 on file (BIS + DOB NOW)
▸Plans & Drawings23
▸DOB NOWPlans/Sketch22
09/06/2026M00065816-I1Request digital key ↗
08/23/2026M08023136-I1Request digital key ↗
08/23/2026M08023136-P1Request digital key ↗
Showing 3 of 22 on file for this type
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/05/2026M00263108-I1Request digital key ↗
▸Applications & Permits38
▸BISPLAN / WORK APPROVAL APPLICATION26
06/04/2019123688553Open ↗
06/13/2018122990175Open ↗
06/08/2018122990175Open ↗
Showing 3 of 26 on file for this type
▸BISWORK PERMIT APPLICATION11
06/13/2019122923284Open ↗
06/12/2019122842718Open ↗
05/30/2018122923284Open ↗
Showing 3 of 11 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
11/24/2015121406148Open ↗
▸Seals & Professional Certifications61
▸DOB NOWDPL-1: Design Professional Seal & Signature23
09/06/2026M00065816-I1Open ↗
09/05/2026M00263108-I1Open ↗
09/02/2026M00651899-I1Open ↗
Showing 3 of 23 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION21
06/04/2019123688553Open ↗
06/04/2019123688553Open ↗
05/07/2018122923284Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/23/2026M01242802-I1Open ↗
09/01/2026M01257145-P1Open ↗
09/01/2026M01319540-P1Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
04/24/2017122842718Open ↗
04/07/2017122990175Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
04/24/2017122842718Open ↗
04/12/2017122990175Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026M08023136-I1Open ↗
08/27/2026M08023136-P1Open ↗
▸Trade Schedules & Equipment8
▸BISSCHEDULE B - PLUMBING2
01/10/2012120938021Open ↗
01/10/2012120930920Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
06/04/2019123688553Open ↗
04/12/2017122990175Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026M01177085-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026M01177085-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/13/2026M01177085-I1Open ↗
▸DOB NOWElectric Cut-Off1
08/13/2026M01177085-I1Open ↗
▸Safety & Tenant Protection21
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist17
08/17/2026M01248739-P1Open ↗
08/13/2026M01249829-P1Open ↗
08/13/2026M01177085-P4Open ↗
Showing 3 of 17 on file for this type
▸BISTenant Protection Plan and Notes4
06/19/2017122923284Open ↗
06/19/2017122923284Open ↗
04/24/2017122842718Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos25
▸BISASBESTOS: CERTIFICATION (DEP ACP5)11
06/04/2019123688553Open ↗
06/13/2018122990175Open ↗
06/13/2018122414100Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/18/2026M01177085-P4Open ↗
08/14/2026M00651899-I1Open ↗
08/13/2026M01177085-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
01/10/2012120930920Open ↗
09/15/2010120450797Open ↗
09/15/2010120450797Open ↗
Showing 3 of 4 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
10/17/2012121406148Open ↗
▸DOB NOWRodent Control1
08/13/2026M01177085-I1Open ↗
▸Energy Compliance19
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS15
06/04/2019123688553Open ↗
06/04/2019123688553Open ↗
05/07/2018122923284Open ↗
Showing 3 of 15 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
09/23/2020122842718Open ↗
02/06/2018122355101Open ↗
11/24/2015121406148Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/23/2020122842718Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/23/2020122842718Open ↗
▸BISTECHNICAL REPORT: PILE DRIVING1
01/23/2017122355101Open ↗
▸Approvals, Objections & Sign-offs11
▸BISADMINISTRATIVE OBJECTIONS5
10/17/2012121406148Open ↗
01/10/2012120938021Open ↗
01/10/2012120930920Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
09/23/2020122842718Open ↗
02/06/2018122355101Open ↗
11/24/2015121406148Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/13/2018122414100Open ↗
05/25/2018122842718Open ↗
▸BISCONSTRUCTION CODE DETERMINATION1
10/09/2013121406148Open ↗
▸Cost, Insurance & Ownership15
▸BISCOST AFFIDAVIT15
09/23/2020122842718Open ↗
06/04/2019123688553Open ↗
02/06/2018122355101Open ↗
Showing 3 of 15 on file for this type
▸Filing & Intake Forms21
▸BISEFILING COVER SHEET11
06/04/2019123688553Open ↗
06/19/2017122923284Open ↗
06/19/2017122923284Open ↗
Showing 3 of 11 on file for this type
▸BISBOROUGH INTAKE FORM8
06/08/2018122990175Open ↗
06/08/2018122414100Open ↗
05/22/2018122842718Open ↗
Showing 3 of 8 on file for this type
▸BISADDITIONAL INFORMATION2
05/31/2018122923284Open ↗
12/13/2012121406148Open ↗
▸Other Documents10
▸DOB NOWProperty Ownership Certification4
08/18/2026M01177085-P4Open ↗
08/13/2026M01177085-P1Open ↗
08/13/2026M01177085-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStructure Photographs4
08/13/2026M01177085-I1Open ↗
08/13/2026M01177085-P4Open ↗
08/13/2026M01177085-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWCommunity Board Notification1
08/13/2026M01177085-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1