← Back
Large suburban residence
921 OCEAN PARKWAY
BROOKLYN · BIN 3170870
💬 Discuss this project
1935Year Built
2.75Stories
A3Building Class
R5Zoning
4,360 sfGross Floor Area
1Units
Large suburban residence · 6,000 sf lot · 0.73 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 11p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/01/2016$3.1M—Private party → Private party$711/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PHILIP TOSCANO ARCHITECTS307/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DANA TREZZA303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STARLITE PLUMBING CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PHILIP TOSCANO, ARCHITECT2474307/30/2024
Building Lifecycle
All (13)Filed (3)Permit Issued (2)Signed Off (1)Inspection (3)Objection (2)Special Inspection (2)
12/16/2024
Signed off — Alteration
Plumbing work filed to relocate existing gas meter & replace a portion of exiting gas piping from lot line to relocated gas meter & from relocated meter to two (2) existing gas boilers. No change to use, egress, nor occupancy
B00959009-I1
08/19/2024
Permit issued — Plumbing
B00959009-I1-PL
08/19/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/05/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
PHILIP TOSCANO
07/30/2024
Filed — Alteration
Plumbing work filed to relocate existing gas meter & replace a portion of exiting gas piping from lot line to relocated gas meter & from relocated meter to two (2) existing gas boilers. No change to use, egress, nor occupancy
B00959009-P2
07/24/2024
Objection resolved — Addressed
07/12/2024
Objection raised — Scope
07/10/2024
Filed — Alteration
Plumbing work filed to relocate existing gas meter & replace a portion of exiting gas piping from lot line to relocated gas meter & from relocated meter to two (2) existing gas boilers. No change to use, egress, nor occupancy
B00959009-P1
02/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
PHILIP TOSCANO
01/30/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/23/2024
Permit issued — Plumbing
B00959009-I1-PL
11/15/2023
Filed — Alteration
Plumbing work filed to relocate existing gas meter & replace a portion of exiting gas piping from lot line to relocated gas meter & from relocated meter to two (2) existing gas boilers. No change to use, egress, nor occupancy
B00959009-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offB-EZ PLUMBING & HTG CORP08/19/2024
DOB NOWPlumbingSigned-offB-EZ PLUMBING & HTG CORP01/23/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/19/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/05/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/30/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
08/02/2024Fire-Resistant Penetrations and JointsPHILIP TOSCANOspecial
02/04/2024Fire-Resistant Penetrations and JointsPHILIP TOSCANOspecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026B00959009-P2Request digital key ↗
08/24/2026B00959009-I1Request digital key ↗
08/14/2026B00959009-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026B00959009-P2Open ↗
08/24/2026B00959009-P1Open ↗
08/24/2026B00959009-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026B00959009-I1Open ↗
08/23/2026B00959009-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026B00959009-P2Open ↗
08/24/2026B00959009-I1Open ↗
08/14/2026B00959009-P1Open ↗