HPD09/13/2026§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD09/13/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD09/13/2026§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD06/10/2026§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSISTING OF HEAVY DUTTY GARBAGE BAGS, RECYCLING AND CARDBOARD BOXES AT FLOOR YARD AT NORTH
HPD05/08/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH GLASS AT 2ND WINDOW FROM WEST AT NORTH WALL AT PUBLIC HALL, 4th STORY
HPD05/08/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL AT PUBLIC HALL, 1st STORY
HPD05/08/2026§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL AT PUBLIC HALL, 1st STORY
HPD05/08/2026§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL 1ST STORY AT PUBLIC HALL, 1st STORY
ECB01/29/2026CLASS 1 ITEM: INOPERATIVE DISC BRAKE MONITOR; DOES NOT ACTIVATE ROPE GRIPPER. CLASS 2 ITEMS: INOPERATIVE CAR PHONE. MISSING SAFETY KEY. REMOVE CIRCUITS FROM BREAKER PANEL THAT ARE NOT PART OF THE OPERATION OF T$1K due
DOB08/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB02/28/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED AT E 163 ST AT KENNEDYS FRIED CHICKEN STOVE AN EXHAUST FOR COMMERICAL STOVEIS DEFECTIVE. TERMINATED LIGHT ABOVE WINDOW, TERMINATION IS INCORRECT.$3K due
ECB02/26/2019CU9L10;CU26D13,CU51L10,CU52B10; 52K2; CU76K10,26L10. 9L10-CAR SADDLE WORN AND NOT SECURE; 26D13-TOP OF CAR ESCAPE HATCH NOT SECURED; 51L10-SLACK CABLE SWITCH NOT WORKING DEVICE STILL ABLE TO RUN; 52B10-HOIST$1K due
ECB12/27/2018FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT TIME OF INSPECTION I OBSERVED ON THE SIDE OF THE BUILDING LOCATED AT EAST 163RD STREET AND EXHAUST FOR A COMMERICIAL STOVE LOCATED IN THE KENNEDYS$3K due
DOB10/14/2010V-DOB VIOLATION - ACTIVE
DOB10/14/2010V-DOB VIOLATION - ACTIVE
ECB05/07/2020SERVICE NOT RESTOREDNothing owed — awaiting certificate of correction
ECB04/03/202096X10-FAILURE TO MAINTAIN BUIDLING IN CODE-COMPLIANT MANNER.SERVICE EQUIPMENT ELEVATOR PER BC3001.2;27-987.DOB RECORDS SHOWS THE ONLY ELEVATOR DEVICE IN BUILDING AS ACTIVE.UPON INSPECTION,THIS DEVICE IS FOUND TNothing owed — awaiting certificate of correction
ECB03/09/2020RESTORE TO SERVICE SO INSPECTION CAN BE MADE BY THIS DEPARTMENT (NYCDOB).Nothing owed — awaiting certificate of correction
ECB12/08/201997-X-17 UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING HAZARDOUS CONDITIONS AS PER 1RCNY 11-02. THIS DEVICE PROVIDES SERVICE IN A SIX STY BUILDING. REMEDY. RESTORE TO SERVICE IMMEDIATLEY ANDNothing owed — awaiting certificate of correction
ECB10/01/2019(CEASE USE-16R9/52B12/55B12)(42Q3/42B9/56Y13/39O2/40O2/59B5)CEASE USE CONTINUE,THE ONLY DEVICE ON THIS 6 STORY BUILDING REMAINS OUT OF SERVICE CREATING A HAZARDOUS CONDITION FOR TENANTS,VISITORS AND EMERGENCY RNothing owed — awaiting certificate of correction
ECB08/20/2019CEASE USE(52-B-12, 52-BB-12, 16-P-07) 02-X-10, 42-D-06, 59-B-07, 56-Y-13, 40-D-06, 70-D-07, 37-O-02, 39-I-10, 26-D-03, 53-U-07. CEASE USE CONTINUE AGGRAVATED 11 CONDITION PER 1RCNY 102-01(F). THE CEASE USE VIONothing owed — awaiting certificate of correction
ECB07/21/201997X17 UPON INSPECTION THE DEVICE WAS FOUND TO BE OUT OF SERVICE. AS PER 1RCNY 11-02. RMDY: RESTORE TO SERVICE IMMEDIATELY CALL 212-393- 2435.Nothing owed — awaiting certificate of correction
ECB05/09/2019C/U 52B12,55B12,16P07,02X10,42D06,59B07,56Y13,40D06,70P07,80B07,37O02100B10,39I10,30Q03,32H10,53U07,29D06,05B10,03I10,15M07,37O02;(52)C/U RESHACKLE DRUM TO CAR HOIST ROPE AND APPLY TAG IN ACCORDANCE TO CODE(55)Nothing owed — awaiting certificate of correction
ECB05/10/2018FAILURE TO MAINTAIN BUILDING CODE COMPLIANT MANNER.OBSERVED ON 05/10/2018 AT ABOVE ADDRESS(KENNEDY'S)COMMERCIAL STOVE EXHAUST IS NOT TERMINATE CORRECTLY.THE STOVE EXHAUST IS TERMINATED RIGHT ABOVE THE WINDOW ONNothing owed — awaiting certificate of correction
ECB04/03/2018B254,50A,50B,50C,50D,50E,50F,50G.50H. AS PER CLASS 2 (254) 28.301.1 FAILURE TO MAINTAIN 50A-DOGLEGS MISSING FROM FRONT AND REAR ACCESS DOORS ON BOILER; 50B-NO SHUT-OFF AND ANTI-SIPHON VALVES ON FUEL OIL SUPPLNothing owed — awaiting certificate of correction
ECB03/10/2018FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED @ SIDE OF BUILDING ON E 183RD STREET AN EXHAUST FOR A COMMERCIAL STONE INCORRECTLY TERMINATED @ THE 1ST FLOOR LEVEL OF BUILDING AND NOT AT THE TOPNothing owed — awaiting certificate of correction
ECB11/30/2017FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED IN CELLAR WASTE LINE FEAKING AND THE PIPE BROKEN IN THE BOILR ROOM A UNON LEAKING ON A WATER SUPPLY LINE IN THE ELECTRICAL ROOM AND A WATER SUPPLYNothing owed — awaiting certificate of correction
ECB11/30/2017FAILURE TO HAVE NEW OR ALTERED PLUMBING TESTED.OBSERVED IN CELLAR APPROX. FIFTEEN FEET OF FOUR INCH WASTE PIPE AND FITTINGS,TWENTY FEET OF TWO INCH WASTE PIPE AND FITTINGS AND SIX FEET OF ONE AND A HALFNothing owed — awaiting certificate of correction
ECB11/30/2017FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT SITEOF BUILDING ON E.163RD ST A COMMERCIAL STOVE EXHAUST INCORRECTLY TERM INATED AT 1ST FLOOR LEVEL.THIS EXHAUST IS SUPPORTED TO TERMINATE BY CNothing owed — awaiting certificate of correction
ECB09/30/2016MSC. VIOLATIONS: FGC408.2 FUTURE CONNECTIONS EXIST ON GAS PIPING.AT THE TIME OF MY INSPECITON, 12:30PM ON 9/30/2016 AT THE ABOVE PLACE OF OCCURRENCE ADDRESS I OBSERVED SEVERAL FUTURE CONNECTIONS ON THE GASNothing owed — awaiting certificate of correction
ECB10/02/2000OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O #33685 STATES FIRST FL. 3 APTS. & STORES IS NOW 2 APTS. AND EXTENDED HARDWARE STORE INTO APT. (E. 163 ST. SIDE) REMEDY:AMEND C OF O OR DISCONTINUE ILLEGAL USE.Nothing owed — awaiting certificate of correction