← Back
Multi-story retail building (2+)
981 3 AVENUE
MANHATTAN · BIN 1038642
💬 Discuss this project
1912Year Built
4Stories
K2Building Class
C5-2Zoning
7,400 sfGross Floor Area
1Units
0 Open Violations
Multi-story retail building (2+) · Owner of record: 981 THIRD REALTY, LLC · 2,109 sf lot · 3.51 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalFire ProtectionCivil
Floor 43p · 2 filings · 8 docs
Floor 32p · 1 filing · 20 docs
Floor 2
Floor 12p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ORPHEUS MANAGEMENT2703/22/2026
EAST 57TH STREET RUGS803/21/2026
981 THIRD REALTY203/21/2026
EAST 57 RUGES203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LAWRENCE MAREK ARCHITECT312/13/2023
TAN ENGINEERING PC211/03/2022
M JUST ARCHITECTURE PC108/06/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JUST ARCHITECTURE203/21/2026
CHERICO KING ARCHITECT P C1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MICHELLE KUO CORPGeneral Contractor803/21/2026
CASELLA CONSTRUCTION CORP.General Contractor203/21/2026
HEMNAUTH, SUDESHElectrical103/21/2026
WALTON, MARCElectrical103/21/2026
RRP PLUMBING CORPFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHERICO KING ARCHITECT PC5674312/13/2023
TAN ENGINEERING, P.C.1291211/03/2022
Building Lifecycle
All (78)Filed (6)Permit Issued (6)Signed Off (4)Violation (36)Inspection (5)Objection (2)Special Inspection (19)
05/08/2024
Signed off — Alteration
M00690566-I1
04/02/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/29/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/29/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/04/2024
Signed off — Alteration
IT IS PROPOSED TO REMOVE OF ALL INTERIOR NON LOAD-BEARING PARTITIONS, FINISHES AND HUNG CEILING FROM 1st FLOOR TO 4th FLOOR. INSTALL NEW NON LOAD-BEARING PARTITIONS, WALL AND CEILING FINISHES. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00595673-I1
02/28/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
12/14/2023
Special inspection requirement — Interior lighting power
LAWRENCE MAREK
12/14/2023
Special inspection requirement — Lighting controls
LAWRENCE MAREK
12/14/2023
Special inspection requirement — Energy Code Compliance Inspections
LAWRENCE MAREK
12/14/2023
Special inspection requirement — Fire-Resistance Rated Construction
LAWRENCE MAREK
12/13/2023
Filed — Alteration
IT IS PROPOSED TO REMOVE OF ALL INTERIOR NON LOAD-BEARING PARTITIONS, FINISHES AND HUNG CEILING FROM 1st FLOOR TO 4th FLOOR. INSTALL NEW NON LOAD-BEARING PARTITIONS, WALL AND CEILING FINISHES. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00595673-P2
12/04/2023
Special inspection requirement — Lighting controls
LAWRENCE MAREK
12/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
12/04/2023
Special inspection requirement — Energy Code Compliance Inspections
LAWRENCE MAREK
12/04/2023
Special inspection requirement — Fire-Resistance Rated Construction
LAWRENCE MAREK
12/04/2023
Special inspection requirement — Interior lighting power
LAWRENCE MAREK
10/19/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
10/16/2023
Signed off — Alteration
MODIFY AND RELOCATE EXISTING DUCT WORK FROM FLOOR 001 TO 004. REPLACE DIFFUSERS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00690731-I1
10/11/2023
Permit issued — Sprinklers
M00690566-I1-EW-SP
10/10/2023
Permit issued — Mechanical Systems
M00690731-I1-MS
12/13/2022
Filed — Alteration
IT IS PROPOSED TO REMOVE OF ALL INTERIOR NON LOAD-BEARING PARTITIONS, FINISHES AND HUNG CEILING FROM 1st FLOOR TO 4th FLOOR. INSTALL NEW NON LOAD-BEARING PARTITIONS, WALL AND CEILING FINISHES. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00595673-P1
12/12/2022
Special inspection requirement — Energy Code Compliance Inspections
LAWRENCE MAREK
12/12/2022
Special inspection requirement — Fire-Resistance Rated Construction
LAWRENCE MAREK
12/12/2022
Special inspection requirement — Lighting controls
LAWRENCE MAREK
12/12/2022
Special inspection requirement — Interior lighting power
LAWRENCE MAREK
11/03/2022
Filed — Alteration
M00690566-I1
11/03/2022
Filed — Alteration
MODIFY AND RELOCATE EXISTING DUCT WORK FROM FLOOR 001 TO 004. REPLACE DIFFUSERS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00690731-I1
08/12/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
04/06/2022
Permit issued — General Construction
M00595673-I1-GC
03/02/2022
Special inspection requirement — Energy Code Compliance Inspections
Roger Tan
03/02/2022
Special inspection requirement — Final
Roger Tan
03/02/2022
Special inspection requirement — Mechanical Systems
Roger Tan
02/18/2022
Signed off — Alteration
Install a 8'-0" temporary wood fence to be removed only after completion of all work.
M00572220-I1
12/07/2021
Permit issued — General Construction
M00595673-I1-GC
09/27/2021
Permit issued — General Construction
M00595673-I1-GC
09/20/2021
Filed — Alteration
IT IS PROPOSED TO REMOVE OF ALL INTERIOR NON LOAD-BEARING PARTITIONS, FINISHES AND HUNG CEILING FROM 1st FLOOR TO 4th FLOOR. INSTALL NEW NON LOAD-BEARING PARTITIONS, WALL AND CEILING FINISHES. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00595673-I1
08/11/2021
Permit issued — Construction Fence
M00572220-I1-FN
08/09/2021
Objection raised — Structural
08/09/2021
Objection resolved — Addressed
08/06/2021
Filed — Alteration
Install a 8'-0" temporary wood fence to be removed only after completion of all work.
M00572220-I1
08/06/2021
Special inspection requirement — Final
John Natoli
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/20/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/05/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/26/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/31/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/31/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/10/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/26/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/27/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/27/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/10/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/10/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/20/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
07/20/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/02/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 78 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offRALPH W. LANDOLFI JR.10/11/2023
DOB NOWMechanical SystemsSigned-off18-15 REALTY LLC10/10/2023
DOB NOWGeneral ConstructionSigned-off18-15 REALTY LLC04/06/2022
DOB NOWGeneral ConstructionSigned-off18-15 REALTY LLC12/07/2021
DOB NOWGeneral ConstructionSigned-off18-15 REALTY LLC09/27/2021
DOB NOWConstruction FenceSigned-offCASELLA CONSTRUCTION CORP.08/11/2021
BISOTISSUEDCASELLA CONSTRUCTION CORP.12/08/2021
BISOTRE-ISSUEDCASELLA CONSTRUCTION CORP.08/13/2021
BISOTISSUEDAP-TECH CONTRACTING CORP04/03/2018
BISMHISSUED38 EAST 57TH RUGS LLC08/31/2007
BISPLISSUEDWEXLER PLBG & HTG INC01/23/2007
BISOTISSUEDCAPITAL BUILDERS GROUP INC01/18/2007
BISSPISSUEDABCO-PEERLESS SPRKLR CORP10/07/2005
BIS—ISSUEDFRANK TORRONE & SONS INC09/26/2005
BIS—ISSUEDFRANK TORRONE & SONS INC09/26/2005
BISPLISSUEDWEXLER PLUMBING & HEATING08/24/2005
BISMHISSUEDCAPITAL BUILDERS GROUP INC07/25/2005
BISEQISSUEDCAPITAL BUILDERS GROUP INC07/25/2005
BISOTISSUEDWONDER WORKS CONSTR CORP02/02/2001
BISOTISSUEDWONDER WORKS CONSTR CORP03/16/2000
BISOTISSUEDWONDER WORKS CONSTR CORP04/29/1998
BISPLISSUEDNEW YORK STANDARD MECH CORP03/06/1998
BISOTISSUEDWONDER WORKS CONSTR CORP02/09/1998
BISMHISSUEDDIAMOND MECH CORP10/30/1997
BISSPISSUEDCAPITOL FIRE SPKL CO,INC10/24/1997
BISEQISSUEDSPRING SCAFFOLDING INC.09/22/1997
BISOTISSUEDDIAMOND MCHANCL.CORP08/18/1997
BIS—ISSUEDWONDER WORKS CONSTR CORP07/02/1997
BISOTISSUEDWONDER WORKS CONSTR CORP07/01/1997
BISEQISSUEDWONDER WORKS CONSTR CORP07/01/1997
BISMHISSUEDYUANG FA CONST. INC08/23/1995
BIS—ISSUEDACE SIGN & RIGGING CORP02/08/1994
BIS—ISSUEDACE SIGN & RIGGING CORP02/08/1994
BIS—ISSUEDACE SIGN & RIGGING CORP02/08/1994
BISMHISSUEDHSU & ASSOC INC06/09/1993
BISPLISSUEDCHINATOWN PLBG & HTG INC06/02/1993
BISEQISSUEDHSU & ASSOC INC04/22/1993
BISMHISSUEDHSU & ASSOC INC04/22/1993
BISFPISSUEDLUND FIRE PRODUCTS CO INC.05/26/1992
1 project · most recent 02/02/2022
General Wiring
FiledStatusContractorScope
02/02/2022CompleteJEM ELEC'L CONTR. CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/02/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/29/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/29/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/28/2024Pass-Final General Construction Non-Directive 14PassView ↗
10/19/2023Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
12/14/2023Fire-Resistant Penetrations and JointsCherico Kingspecial
12/14/2023Interior lighting powerLAWRENCE MAREKenergy_progress
12/14/2023Lighting controlsLAWRENCE MAREKenergy_progress
12/14/2023Energy Code Compliance InspectionsLAWRENCE MAREKprogress
12/14/2023Fire-Resistance Rated ConstructionLAWRENCE MAREKprogress
12/04/2023Lighting controlsLAWRENCE MAREKenergy_progress
12/04/2023Fire-Resistant Penetrations and JointsCherico Kingspecial
12/04/2023Energy Code Compliance InspectionsLAWRENCE MAREKprogress
12/04/2023Fire-Resistance Rated ConstructionLAWRENCE MAREKprogress
12/04/2023Interior lighting powerLAWRENCE MAREKenergy_progress
12/12/2022Energy Code Compliance InspectionsLAWRENCE MAREKprogress
12/12/2022Fire-Resistance Rated ConstructionLAWRENCE MAREKprogress
12/12/2022Lighting controlsLAWRENCE MAREKenergy_progress
12/12/2022Interior lighting powerLAWRENCE MAREKenergy_progress
08/12/2022Fire-Resistant Penetrations and JointsCherico Kingspecial
03/02/2022Energy Code Compliance InspectionsRoger Tanprogress
03/02/2022FinalRoger Tanprogress
03/02/2022Mechanical SystemsRoger Tanspecial
08/06/2021FinalJohn Natoliprogress
▾Documents — 114 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/01/2026M00690566-I1Request digital key ↗
09/01/2026M00690731-I1Request digital key ↗
09/01/2026M00595673-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits14
▸BISPLAN / WORK APPROVAL APPLICATION9
06/17/2021123170291Open ↗
04/28/2020140896332Open ↗
03/14/2018122807418Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION4
12/08/2021140896332Open ↗
08/13/2021140896332Open ↗
04/04/2018123170291Open ↗
Showing 3 of 4 on file for this type
▸BISTEMPORARY FENCE APPLICATION & PERMIT1
08/12/2021140896332Open ↗
▸Seals & Professional Certifications37
▸DOB NOWProgress Inspector Seal & Signature14
09/01/2026M00690731-I1Open ↗
08/30/2026M00595673-P1Open ↗
08/30/2026M00595673-P1Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
11/15/2017123170291Open ↗
07/07/2016122807418Open ↗
09/29/2010120433762Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/01/2026M00690566-I1Open ↗
09/01/2026M00595673-I1Open ↗
09/01/2026M00595673-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026M00690731-I1Open ↗
08/30/2026M00595673-P1Open ↗
08/26/2026M00595673-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
11/15/2017123170291Open ↗
08/09/2010120433762Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/15/2017123170291Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
04/28/2020140896332Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/09/2010120433762Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
04/28/2020140896332Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/01/2026M00690566-I1Open ↗
09/01/2026M00595673-P1Open ↗
09/01/2026M00595673-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/28/2020140896332Open ↗
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
04/04/2018123170291Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
08/09/2010120433762Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY6
05/24/2022140896332Open ↗
05/24/2022140896332Open ↗
08/20/2021123170291Open ↗
Showing 3 of 6 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
05/24/2022140896332Open ↗
08/20/2021123170291Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/15/2017123170291Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00595673-I1Open ↗
▸Inspections & Test Reports10
▸BISTECHNICAL REPORT: RESPONSIBILITY6
05/24/2022140896332Open ↗
05/24/2022140896332Open ↗
08/20/2021123170291Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
05/25/2022140896332Open ↗
05/25/2022140896332Open ↗
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT1
08/12/2021140896332Open ↗
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT1
08/12/2021140896332Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
05/25/2022140896332Open ↗
08/20/2021123170291Open ↗
09/29/2010120433762Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
02/21/2013121522370Open ↗
08/09/2010120433762Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT9
05/24/2022140896332Open ↗
05/24/2022140896332Open ↗
08/20/2021123170291Open ↗
Showing 3 of 9 on file for this type
▸BISDEPT OF FINANCE VERIFICATION1
04/03/2013121522370Open ↗
▸Filing & Intake Forms9
▸BISEFILING COVER SHEET4
11/15/2017123170291Open ↗
07/07/2016122807418Open ↗
02/21/2013121522370Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION3
05/19/2020140896332Open ↗
05/14/2020140896332Open ↗
04/03/2013121522370Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/28/2020140896332Open ↗
▸BISBOROUGH INTAKE FORM1
12/08/2021140896332Open ↗
▸Other Documents4
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
03/13/2013121522370Open ↗
03/11/2013121522370Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
05/19/2020140896332Open ↗
▸BISPLOT DIAGRAM1
07/07/2016122807418Open ↗