← Back
Gas or electric utility
GULF AVENUE
STATEN ISLAND · BIN 5129201
💬 Discuss this project
0Year Built
—Stories
U2Building Class
M2-1Zoning
0 sfGross Floor Area
0Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Gas or electric utility · Owner of record: BROOKLYN UNION GAS COMPANY · 480,045 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbing
Roof7p · 3 filings · 20 docs
Floor 19p · 2 filings · 20 docs
Basement6p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NATIONAL GRID5608/29/2026
BROOKLYN UNION GAS CO403/22/2026
HERBERT CONST CO103/22/2026
HERBERT CONSTRUCTION103/22/2026
JLL103/22/2026
KEYSPAN103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RPO803/21/2026
CONSTRUCTION PERMIT SERVICES303/21/2026
JAM CONSULTANTS, INC.603/21/2026
EA DESIGN GROUP203/21/2026
CONVERSANO ASSOCIATES, INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BANCKER CONSTRUCTION CORPGeneral Contractor807/08/2026
CROSS CHECK MECH. CORPPlumbing807/08/2026
R.W. DAKE & CO.,INCGeneral Contractor404/09/2026
MATCO SERVICE CORPGeneral Contractor307/08/2026
D.R. CONTRACTINGGeneral Contractor303/21/2026
CLUNE CONSTRUCTION CO LPGeneral Contractor207/08/2026
EISENSTEIN, SAMUELElectrical203/21/2026
PAR PLUMBING CO., INCPlumbing107/08/2026
DAVID MILLERElectrical103/21/2026
JOSEPH MARONEElectrical103/21/2026
MILLER DAVIDElectrical103/21/2026
PAIGE, JAMES ROBERTElectrical103/21/2026
SANTORA, FRANKElectrical103/21/2026
AMC ELEC'L SERVICES, INC.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALL CITY ENGINEERING PC7115608/06/2025
AEIS LLC280109/13/2024
OLA CONSULTING ENGINEERS,1955107/26/2024
ALAN MARGOLIN & ASSOC423211/17/2022
CROSSCHECK INSPECTION SER544103/23/2022
Building Lifecycle
All (142)Filed (23)Permit Issued (22)Signed Off (11)Violation (23)Inspection (11)Objection (22)Special Inspection (30)
09/04/2026
Objection raised — Scope
09/04/2026
Objection raised — Accessibility
08/14/2026
Signed off — Alteration
Herewith filing to replace existing unit on the roof with a new one as per the plans. No change in use, egress or occupancy.
S01071172-S1
08/13/2026
Filed — Alteration
HEREBY FILING INSTALLATION OF NEW VEHICULAR PARKING AREA, STORM WATER MANAGEMENT, TRENCH DRAIN & PAVEMENT AT EXISTING LOADING DOCK. APPROVED DETERMINATION # PDA00013785. SUBSEQUENT STRUCTURAL AND FOUNDATION WORK TO BE FILED SEPARATELY.
S01425859-I1
07/15/2026
Filed — Alteration
Herewith filing to replace existing unit on the roof with a new one as per the plans. No change in use, egress or occupancy.
S01071172-P3
07/02/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
07/02/2026
Special inspection requirement — Final
06/12/2026
Signed off — Alteration
REMOVE EXISTING GAS FIRED CHILLER AND GAS FIRED UNIT HEATERS. REPLACE EXISTING 2 SET BOILER MODULES WITH NEW IN THE BOILER ROOM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
S00939087-I1
05/29/2026
Filed — Alteration
Herewith filing to replace existing unit on the roof with a new one as per the plans. No change in use, egress or occupancy.
S01071172-P2
04/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/02/2026
Violation issued (FDNY_NOV, closed)
02/02/2026
Violation issued (FDNY_NOV, closed)
01/27/2026
Violation issued (FDNY_ORDER, closed)
01/27/2026
Objection resolved — Addressed
01/26/2026
Objection raised — Admin
01/08/2026
Filed — Alteration
Herewith filing to replace existing unit on the roof with a new one as per the plans. No change in use, egress or occupancy.
S01071172-P1
01/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/23/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
12/12/2025
Permit issued — Plumbing
S01071172-S1-PL
10/27/2025
Permit issued — General Construction
S01091681-I1-GC-CX
10/16/2025
Signed off — Alteration
DESIGN INCLUDES REPLACING EXISTING 2 SET BOILER MODULES WITH NEW. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
S00936172-I1
10/03/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
08/18/2025
Special inspection requirement — Maintenance information
Liangkai Xia
08/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
Liangkai Xia
08/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
Liangkai Xia
08/18/2025
Special inspection requirement — Energy Code Compliance Inspections
Liangkai Xia
08/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Liangkai Xia
08/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Liangkai Xia
08/06/2025
Filed — Alteration
REMOVE EXISTING GAS FIRED CHILLER AND GAS FIRED UNIT HEATERS. REPLACE EXISTING 2 SET BOILER MODULES WITH NEW IN THE BOILER ROOM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
S00939087-P3
07/23/2025
Permit issued — Plumbing
S00939087-I1-PL
07/23/2025
Permit issued — Boiler Equipment
S00936172-I1-BE
07/02/2025
Permit issued — Plumbing
S00939087-I1-PL
07/02/2025
Permit issued — Boiler Equipment
S00936172-I1-BE
06/03/2025
Signed off — Alteration
DESIGN INCLUDES REPLACE EXISTING COOLING TOWER AND CHILLER SET WITH AIR COOLED CHILLER, REPLACE EXISTING GAS FIRED OUTSIDE AIR UNIT WITH NEW. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
S00950074-I1
05/27/2025
Filed — Alteration
DESIGN INCLUDES REPLACE EXISTING COOLING TOWER AND CHILLER SET WITH AIR COOLED CHILLER, REPLACE EXISTING GAS FIRED OUTSIDE AIR UNIT WITH NEW. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
S00950074-P2
05/15/2025
Signed off — Alteration
Herewith filing to replace existing unit on the roof with a new one as per the plans. No change in use, egress or occupancy.
S01071172-I1
03/28/2025
Special inspection requirement — HVAC-R and service water heating system controls
Liangkai Xia
03/28/2025
Special inspection requirement — Chimneys and vents
Liangkai Xia
03/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Liangkai Xia
03/28/2025
Special inspection requirement — Mechanical Systems
Liangkai Xia
03/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Liangkai Xia
03/28/2025
Special inspection requirement — Final
Liangkai Xia
03/28/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Liangkai Xia
03/28/2025
Special inspection requirement — HVAC-R and service water heating equipment
Liangkai Xia
03/28/2025
Special inspection requirement — Maintenance information
Liangkai Xia
02/12/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/13/2025
Violation issued (FDNY_NOV, closed)
12/17/2024
Violation issued (FDNY_ORDER, closed)
12/10/2024
Permit issued — Mechanical Systems
S00950074-I1-MS
11/20/2024
Objection raised — Scope
11/20/2024
Objection resolved — Addressed
11/15/2024
Permit issued — Foundation
S01091681-I1-GC-CX
11/04/2024
Filed — Alteration
REMOVE EXISTING GAS FIRED CHILLER AND GAS FIRED UNIT HEATERS. REPLACE EXISTING 2 SET BOILER MODULES WITH NEW IN THE BOILER ROOM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
S00939087-P2
11/04/2024
Special inspection requirement — HVAC-R and service water heating system controls
Liangkai Xia
11/04/2024
Special inspection requirement — Maintenance information
Liangkai Xia
11/04/2024
Special inspection requirement — Energy Code Compliance Inspections
Liangkai Xia
11/04/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Liangkai Xia
11/04/2024
Special inspection requirement — HVAC-R and service water heating equipment
Liangkai Xia
10/08/2024
Permit issued — Mechanical Systems
S01071172-I1-MS
10/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Liangkai Xia
Latest 60 of 142 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROSS CHECK MECH. CORP12/12/2025
DOB NOWGeneral ConstructionPermit IssuedR.W. DAKE & CO.,INC10/27/2025
DOB NOWPlumbingSigned-offCROSS CHECK MECH. CORP07/23/2025
DOB NOWBoiler EquipmentSigned-offCROSS CHECK MECH. CORP07/23/2025
DOB NOWPlumbingSigned-offCROSS CHECK MECH. CORP07/02/2025
DOB NOWBoiler EquipmentSigned-offCROSS CHECK MECH. CORP07/02/2025
DOB NOWMechanical SystemsSigned-offMATCO SERVICE CORP12/10/2024
DOB NOWFoundationPermit IssuedR.W. DAKE & CO.,INC11/15/2024
DOB NOWMechanical SystemsSigned-offMATCO SERVICE CORP10/08/2024
DOB NOWPlumbingSigned-offCROSS CHECK MECH. CORP10/02/2024
DOB NOWPlumbingSigned-offCROSS CHECK MECH. CORP09/05/2024
DOB NOWBoiler EquipmentSigned-offCROSS CHECK MECH. CORP09/05/2024
DOB NOWProtection and Mechanical MethodsSigned-offBANCKER CONSTRUCTION CORP01/10/2023
DOB NOWConstruction FenceSigned-offBANCKER CONSTRUCTION CORP01/10/2023
DOB NOWGeneral ConstructionSigned-offBANCKER CONSTRUCTION CORP01/09/2023
DOB NOWGeneral ConstructionSigned-offBANCKER CONSTRUCTION CORP12/05/2022
DOB NOWProtection and Mechanical MethodsSigned-offBANCKER CONSTRUCTION CORP11/22/2022
DOB NOWConstruction FenceSigned-offBANCKER CONSTRUCTION CORP11/22/2022
DOB NOWMechanical SystemsSigned-offCLUNE CONSTRUCTION CO LP03/25/2022
DOB NOWPlumbingSigned-offPAR PLUMBING CO., INC03/23/2022
DOB NOWGeneral ConstructionSigned-offCLUNE CONSTRUCTION CO LP03/18/2022
DOB NOWCurb CutPermit IssuedD.R. CONTRACTING06/04/2019
BISFSISSUEDCHAMPION COMBUSTION CORP09/30/2019
BISMHISSUEDMATCO SERVICE CORP03/13/2019
BISOTISSUEDBLUE STAR GROUP LLC05/29/2018
BISOTISSUEDEAST END BUILDING SERVICE03/28/2018
BISFSISSUEDEAST END BUILDING SERVICE03/28/2018
BISMHISSUEDSJS CONSTRUCTION CO., INC.02/27/2018
BISOTISSUEDHIGH POWER CONSTR. CORP02/10/2009
BISFPISSUEDEMDI LTD01/21/2006
BISOTISSUEDTRIPLE G CONSTRUCTION CORP09/20/2000
BISFPISSUEDSAFETY CONSULTANT INC.12/13/1994
BIS—ISSUEDCOUNTYNEON SIGN CORP.09/28/1994
BIS—ISSUEDCOUNTYNEON SIGN CORP.09/28/1994
BISOTISSUEDCKR CONTRACTING INC.09/09/1994
BISMHISSUEDHERBERT CONSTRUCTION CO.06/13/1994
BISPLISSUEDMOST PLUMBING & HEATING CORP.06/13/1994
BISMHISSUEDHERBERT CONSTRUCTION CO.05/23/1994
BISSDISSUEDOLYMPIC PLBG & HTG05/20/1994
BISFSISSUEDFENLEY & NICOL ENVIRONMENTAL05/19/1994
+ 1 more permits on file
1 project · most recent 07/15/2026
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
07/15/2026Signed-offMATCO SERVICE CORPHeating Systems
Heating
Absolutaire R354-HMX the value inputted is a percentage for the gas-fired heater output vs input 4,348 BTU · Rooftop Unit ×1
2 projects · most recent 07/15/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/15/2026Signed-offCROSS CHECK MECH. CORPGas
08/06/2025Signed-offCROSS CHECK MECH. CORPGas, Water/Sanitary
3 projects · most recent 04/01/2025
General Wiring
FiledStatusContractorScope
04/01/2025Permit IssuedSRM ELECTRICAL SVC INC1 meters, 1 new_meters
03/03/2023CompleteAMC ELEC'L SERVICES, INC.General Wiring
05/06/2021CompleteAMC ELEC'L SERVICES, INC.General Wiring
1 project · most recent 08/13/2026
Steel
FiledStatusContractorScope
08/13/2026——Steel
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
04/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/23/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
10/03/2025Pass-Final Boiler Equipment InspectionPassView ↗
02/12/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/02/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/30/2024Fail-Final Boiler Equipment InspectionFailView ↗
09/26/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/13/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/01/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/20/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 47
DateRequirementInspectorRole
07/02/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)—special
07/02/2026Final—progress
08/18/2025Maintenance informationLiangkai Xiaenergy_progress
08/18/2025HVAC-R and service water heating system controlsLiangkai Xiaenergy_progress
08/18/2025HVAC-R and service water heating equipmentLiangkai Xiaenergy_progress
08/18/2025Energy Code Compliance InspectionsLiangkai Xiaprogress
08/18/2025Fire-Resistant Penetrations and JointsLiangkai Xiaspecial
08/18/2025HVAC-R and service water piping design and insulationLiangkai Xiaenergy_progress
03/28/2025HVAC-R and service water heating system controlsLiangkai Xiaenergy_progress
03/28/2025Chimneys and ventsLiangkai Xiaspecial
03/28/2025Fire-Resistant Penetrations and JointsLiangkai Xiaspecial
03/28/2025Mechanical SystemsLiangkai Xiaspecial
03/28/2025Energy Code Compliance InspectionsLiangkai Xiaprogress
03/28/2025FinalLiangkai Xiaprogress
03/28/2025HVAC-R and service water piping design and insulationLiangkai Xiaenergy_progress
03/28/2025HVAC-R and service water heating equipmentLiangkai Xiaenergy_progress
03/28/2025Maintenance informationLiangkai Xiaenergy_progress
11/04/2024HVAC-R and service water heating system controlsLiangkai Xiaenergy_progress
11/04/2024Maintenance informationLiangkai Xiaenergy_progress
11/04/2024Energy Code Compliance InspectionsLiangkai Xiaprogress
11/04/2024HVAC-R and service water piping design and insulationLiangkai Xiaenergy_progress
11/04/2024HVAC-R and service water heating equipmentLiangkai Xiaenergy_progress
10/07/2024Fire-Resistant Penetrations and JointsLiangkai Xiaspecial
08/21/2024Concrete - Cast-In-PlaceIAN JONATHAN GONZALESspecial
08/21/2024Subsurface Conditions – Fill Placement & In-Place DensityIAN JONATHAN GONZALESspecial
Latest 25 of 47.
▾Documents — 230 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
08/26/2026S00001632-I1Request digital key ↗
08/24/2026S00665965-I1Request digital key ↗
08/24/2026S00666046-I1Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits30
▸BISPLAN / WORK APPROVAL APPLICATION20
08/04/2022520376913Open ↗
07/14/2022520376913Open ↗
11/24/2021500237362Open ↗
Showing 3 of 20 on file for this type
▸BISWORK PERMIT APPLICATION9
11/26/2019520394500Open ↗
10/01/2019520282328Open ↗
03/14/2019520361180Open ↗
Showing 3 of 9 on file for this type
▸BISELECTRICAL OBJ: OPEN APPLICATIONS1
11/23/2021500237362Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISVERIFY TAX LOT1
11/23/2021500237362Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
11/23/2021500237362Open ↗
▸Seals & Professional Certifications85
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION21
11/26/2019520394500Open ↗
11/22/2019520394500Open ↗
11/08/2019520394500Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature21
08/24/2026S00666046-I1Open ↗
08/24/2026S00666015-I1Open ↗
08/24/2026S00779017-I1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWProgress Inspector Seal & Signature21
09/23/2026S00936172-I1Open ↗
09/02/2026S00939087-I1Open ↗
09/02/2026S00939087-I1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/23/2026S00936172-I1Open ↗
09/02/2026S01071172-I1Open ↗
09/02/2026S00939087-I1Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT6
11/08/2019520394500Open ↗
03/14/2019520361180Open ↗
01/24/2019540159567Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
11/08/2019520394500Open ↗
03/14/2019520361180Open ↗
08/10/2017520310119Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
01/24/2019540159567Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/24/2019540159567Open ↗
▸Trade Schedules & Equipment8
▸BISEQUIPMENT USE APPLICATION/PERMIT3
06/24/2019520361180Open ↗
06/24/2019520361180Open ↗
09/27/2018520310119Open ↗
▸BISEQUIPMENT USE PERMITS2
06/24/2019520361180Open ↗
09/27/2018520310119Open ↗
▸BIS* TEMP PLUMBING SIGNOFF1
11/23/2021500237362Open ↗
▸BISSCHEDULE B - PLUMBING1
09/16/2010520046888Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
11/01/2016520282328Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
06/19/2008510044710Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026S00666046-I1Open ↗
08/24/2026S00666015-I1Open ↗
08/13/2026S00665965-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
03/14/2019520361180Open ↗
11/01/2016520282328Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/16/2010520046888Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
06/19/2008510044710Open ↗
▸Energy Compliance21
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS12
11/26/2019520394500Open ↗
11/08/2019520394500Open ↗
08/12/2019520282328Open ↗
Showing 3 of 12 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
09/17/2020520394500Open ↗
08/12/2019520282328Open ↗
08/08/2019520282328Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWPreliminary Commissioning Report Certification3
08/20/2026S00939087-I1Open ↗
08/13/2026S00936172-I1Open ↗
08/13/2026S00950074-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/18/2020520394500Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
09/17/2020520394500Open ↗
01/24/2019540159567Open ↗
▸BISSOIL REPORT1
01/24/2019540159567Open ↗
▸Approvals, Objections & Sign-offs19
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
09/18/2020520394500Open ↗
08/31/2020500433603Open ↗
01/15/2020520282328Open ↗
Showing 3 of 9 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
11/09/2017520320215Open ↗
08/04/2017520310119Open ↗
11/01/2016520282328Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/17/2019520361180Open ↗
09/15/2008510044710Open ↗
▸BISLetter from Homeowner for Withdrawal1
07/30/2020520046888Open ↗
▸BISSUPERSEDING LETTER1
10/01/2019520282328Open ↗
▸DOB NOWCompliance letter1
08/13/2026S00001632-I1Open ↗
▸Cost, Insurance & Ownership14
▸BISCOST AFFIDAVIT13
09/17/2020520394500Open ↗
12/24/2019520282328Open ↗
11/08/2019520394500Open ↗
Showing 3 of 13 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
10/07/2021500237362Open ↗
▸Filing & Intake Forms16
▸BISEFILING COVER SHEET7
07/14/2022520376913Open ↗
11/08/2019520394500Open ↗
03/14/2019520361180Open ↗
Showing 3 of 7 on file for this type
▸BISBOROUGH INTAKE FORM6
08/04/2022520376913Open ↗
12/24/2019520282328Open ↗
08/12/2019520282328Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION2
07/12/2018520320215Open ↗
01/20/2018520282328Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/24/2019540159567Open ↗
▸Other Documents5
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
09/15/2008510044710Open ↗
06/26/2008510044710Open ↗
▸BISCURB CUT # REQUIRED1
11/23/2021500237362Open ↗
▸BISELECTRICAL OBJ: UNPAID FEES1
11/23/2021500237362Open ↗
▸BIS* VERIFY PW1 INFORMATION1
11/23/2021500237362Open ↗