← Back
Two stories - detached, small or mid-size
131-25 227 STREET
QUEENS · BIN 4278830
💬 Discuss this project
1935Year Built
2.5Stories
A1Building Class
R2Zoning
1,577 sfGross Floor Area
1Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: 466 EAST 26 LLC · 3,200 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 12 docs
Floor 12p · 1 filing · 12 docs
Cellar1p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
169-12 FOCH BLVD1109/13/2026
466 EAST 26 LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/05/2024$485K—— → —$308/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CNS INSPECTION SERVICES LLC307/23/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
R H DRUMMOND EXP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SHANE WALTERSGeneral Contractor407/08/2026
L&J PLG & HTG CO OF NY INPlumbing107/08/2026
LLOYD G DRUMMOND PLBG&GENPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NORMAN C. LOK818207/23/2026
Building Lifecycle
All (24)Filed (3)Permit Issued (4)Signed Off (1)Violation (4)Inspection (8)Special Inspection (4)
07/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NORMAN LOK
07/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
NORMAN LOK
07/27/2026
Special inspection requirement — Interior lighting power
NORMAN LOK
07/27/2026
Special inspection requirement — Insulation placement and R values
NORMAN LOK
07/23/2026
Filed — Alteration
Application filed with conjuntion with Q01029347-I1 for plumbing work as per plan.
Q01029347-P1
06/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/15/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/15/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/12/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/04/2026
Permit issued — General Construction
Q01029347-I1-GC
06/01/2026
Signed off — Alteration
Application filed with conjuntion with Q01029347-I1 for plumbing work as per plan.
Q01029347-S1
10/29/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/07/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/07/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/01/2024
Permit issued — Plumbing
Q01029347-S1-PL
06/05/2024
Violation issued (ECB, closed)
Construction
06/05/2024
Violation issued (ECB, closed)
Construction
05/30/2024
Permit issued — Plumbing
Q01029347-S1-PL
05/21/2024
Permit issued — General Construction
Q01029347-I1-GC
05/16/2024
Filed — Alteration
Application filed with conjuntion with Q01029347-I1 for plumbing work as per plan.
Q01029347-S1
05/16/2024
Filed — Alteration
Application filed with conjuntion with Q01029347-I1 for plumbing work as per plan.
Q01029347-I1
03/18/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/15/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSHANE WALTERS06/04/2026
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN11/01/2024
DOB NOWPlumbingSigned-offLLOYD G DRUMMOND PLBG&GEN05/30/2024
DOB NOWGeneral ConstructionSigned-offSHANE WALTERS05/21/2024
1 project · most recent 07/23/2026
Water/Sanitary
FiledStatusContractorScope
07/23/2026Signed-offL&J PLG & HTG CO OF NY INWater/Sanitary
1 project · most recent 04/03/2024
General Wiring
FiledStatusContractorScope
04/03/2024Permit IssuedCLAIRMONT ELEC'L CONTR'GGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
06/22/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/15/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/15/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/15/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/12/2026Fail-Final General Construction Non-Directive 14FailView ↗
10/29/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/07/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/07/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
07/27/2026Fire-Resistant Penetrations and JointsNORMAN LOKspecial
07/27/2026Fire-Resistance Rated ConstructionNORMAN LOKprogress
07/27/2026Interior lighting powerNORMAN LOKenergy_progress
07/27/2026Insulation placement and R valuesNORMAN LOKenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026Q01029347-P1Request digital key ↗
08/22/2026Q01029347-S1Request digital key ↗
08/22/2026Q01029347-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026Q01029347-P1Open ↗
08/22/2026Q01029347-S1Open ↗
08/22/2026Q01029347-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q01029347-I1Open ↗
08/26/2026Q01029347-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01029347-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/22/2026Q01029347-P1Open ↗
08/22/2026Q01029347-S1Open ↗
08/22/2026Q01029347-I1Open ↗