← Back
Miscellaneous utility property
10 AVENUE
QUEENS · BIN 4624541
💬 Discuss this project
0Year Built
—Stories
U9Building Class
M1-1Zoning
0 sfGross Floor Area
0Units
Miscellaneous utility property · Owner of record: NYC DEPARTMENT OF ENVIRONMENTAL PROTECTION · 2,535 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 14 docs
Floor 1Under Construction29p · 2 filings · 20 docs
CellarUnder Construction29p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK CITY DEPT OF ENVIRONMENTA1604/09/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LYN STAAR ENGINEERING, P.C.203/31/2023
HAZEN AND SAWYER103/31/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HAZEN & SAWYER, P.C.603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BOVE INDUSTRIES, INCGeneral Contractor604/09/2026
INFINITY CONTRACTING SERVGeneral Contractor304/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CNS INSPECTION SERVICES7566103/31/2023
HIRANI ENGINEERING & LAND679203/31/2023
Building Lifecycle
All (56)Filed (3)Permit Issued (9)Inspection (3)Objection (32)Special Inspection (9)
06/09/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/08/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
06/04/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/05/2026
Permit issued — Mechanical Systems
Q08051927-I1-MS
02/10/2026
Permit issued — Mechanical Systems
Q08051927-I1-MS
01/12/2026
Permit issued — Structural
Q08051851-I1-FO
01/12/2026
Permit issued — Structural
Q08051851-I1-ST
01/12/2026
Permit issued — Foundation
Q08051851-I1-GC
11/05/2025
Permit issued — Structural
Q08051851-I1-FO
10/24/2025
Permit issued — Foundation
Q08051851-I1-ST
10/24/2025
Permit issued — General Construction
Q08051851-I1-GC
02/25/2025
Permit issued — Mechanical Systems
Q08051927-I1-MS
09/12/2023
Objection resolved — Addressed
08/03/2023
Objection resolved — Addressed
08/03/2023
Objection resolved — Addressed
08/03/2023
Objection resolved — Addressed
06/13/2023
Objection resolved — Addressed
06/13/2023
Objection resolved — Addressed
06/12/2023
Objection resolved — Addressed
06/12/2023
Objection resolved — Addressed
04/06/2023
Objection raised — Admin
04/06/2023
Objection raised — Energy
04/06/2023
Objection resolved — Addressed
04/06/2023
Objection raised — Energy
04/06/2023
Objection resolved — Addressed
04/06/2023
Objection raised — Energy
04/05/2023
Objection raised — Energy
04/05/2023
Objection raised — Energy
04/05/2023
Objection resolved — Addressed
04/05/2023
Objection raised — Fire_Protection
04/05/2023
Objection resolved — Addressed
04/05/2023
Objection raised — Scope
04/05/2023
Objection raised — Scope
04/05/2023
Objection raised — Scope
04/05/2023
Objection raised — Scope
04/05/2023
Objection resolved — Addressed
04/05/2023
Objection raised — Scope
04/05/2023
Objection resolved — Addressed
04/04/2023
Objection raised — Inspections
04/04/2023
Objection resolved — Addressed
04/04/2023
Objection raised — Scope
04/04/2023
Objection raised — Other
04/04/2023
Objection resolved — Addressed
04/04/2023
Objection raised — Other
03/31/2023
Filed — Alteration
HVAC WORK AT 154TH PUMPING STATION. NYC DEP CAPITAL PROJECT WP-269 PS-DES-2.
Q08051927-I1
03/31/2023
Filed — Alteration
PLUMBING WORK AT 154TH PUMPING STATION. NYC DEP CAPITAL PROJECT WP-269 PS-DES-2.
Q08051947-I1
03/31/2023
Filed — Alteration CO
REMOVAL OF EXISTING AND INSTALLATION OF NEW UNDERGROUND CONCRETE STAIRS, PLATFORMS, ANDRAILINGS, INSTALLATION OF ELECTRICAL ROOM AND COMFORT STATION, INSTALLATION OF NEWDECORATIVE FENCES AT SITE PERIMETER. NYC DEP CAPITAL PROJECT WP-269 PS-DES-2.
Q08051851-I1
12/13/2022
Special inspection requirement — Duct leakage testing, insulation and design
KIRILL KOROSTELEV
12/13/2022
Special inspection requirement — Electrical motors and elevators
KIRILL KOROSTELEV
12/13/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
KIRILL KOROSTELEV
12/13/2022
Special inspection requirement — Maintenance information
KIRILL KOROSTELEV
12/08/2022
Special inspection requirement — Electrical motors and elevators
Jitendra Hirani
12/08/2022
Special inspection requirement — Exterior lighting power
Jitendra Hirani
12/08/2022
Special inspection requirement — Metering
Jitendra Hirani
12/08/2022
Special inspection requirement — Interior lighting power
Jitendra Hirani
12/08/2022
Special inspection requirement — Lighting controls
Jitendra Hirani
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedINFINITY CONTRACTING SERV03/05/2026
DOB NOWMechanical SystemsPermit IssuedINFINITY CONTRACTING SERV02/10/2026
DOB NOWStructuralPermit IssuedBOVE INDUSTRIES01/12/2026
DOB NOWStructuralPermit IssuedBOVE INDUSTRIES01/12/2026
DOB NOWFoundationPermit IssuedBOVE INDUSTRIES01/12/2026
DOB NOWStructuralPermit IssuedBOVE INDUSTRIES11/05/2025
DOB NOWFoundationPermit IssuedBOVE INDUSTRIES10/24/2025
DOB NOWGeneral ConstructionPermit IssuedBOVE INDUSTRIES10/24/2025
DOB NOWMechanical SystemsPermit IssuedINFINITY CONTRACTING SERV02/25/2025
1 project · most recent 03/31/2023
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/31/2023Permit IssuedINFINITY CONTRACTING SERVHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Trane UHXA 253D2B 85,300 BTU · Electric Heater ×4
UHXA 153D2B 51,200 BTU · Electric Heater ×2
ASHDB 5,000 BTU · Electric Heater ×1
Daikin FAQ18TAVJU 495 CFM · Vrf Indoor ×2
RZQ18TAVJU 19,200 BTU · Heat Pump Outdoor ×2
Ventilation
Greenheck AER-S20C-605-VG 100 CFM · Exhaust Fan ×2
QEI-15 2,800 CFM · Exhaust Fan ×2
GB-200HP 4,300 CFM · Exhaust Fan ×1
SP-B110 75 CFM · Exhaust Fan ×1
TCBRS-2-16 3,900 CFM · Exhaust Fan ×1
1 project · most recent 03/31/2023
Storm Water/Sanitary
FiledStatusContractorScope
03/31/2023——Storm, Water/Sanitary
1 project · most recent 05/16/2025
General Wiring
FiledStatusContractorScope
05/16/2025Permit IssuedGILSTON ELEC'L CONTNG LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
06/09/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/08/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/04/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
12/13/2022Duct leakage testing, insulation and designKIRILL KOROSTELEVenergy_progress
12/13/2022Electrical motors and elevatorsKIRILL KOROSTELEVenergy_progress
12/13/2022HVAC-R and service water piping design and insulationKIRILL KOROSTELEVenergy_progress
12/13/2022Maintenance informationKIRILL KOROSTELEVenergy_progress
12/08/2022Electrical motors and elevatorsJitendra Hiranienergy_progress
12/08/2022Exterior lighting powerJitendra Hiranienergy_progress
12/08/2022MeteringJitendra Hiranienergy_progress
12/08/2022Interior lighting powerJitendra Hiranienergy_progress
12/08/2022Lighting controlsJitendra Hiranienergy_progress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026Q08051947-I1Request digital key ↗
08/25/2026Q08051851-I1Request digital key ↗
08/25/2026Q08051927-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q08051851-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature9
08/22/2026Q08051927-I1Open ↗
08/22/2026Q08051851-I1Open ↗
08/22/2026Q08051927-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q08051947-I1Open ↗
08/25/2026Q08051851-I1Open ↗
08/25/2026Q08051927-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q08051851-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q08051851-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter3
08/13/2026Q08051947-I1Open ↗
08/13/2026Q08051851-I1Open ↗
08/13/2026Q08051927-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q08051851-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q08051851-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q08051851-I1Open ↗