← Back
Community center
123-10 143 STREET
QUEENS · Baisley Park · BIN 4261337
💬 Discuss this project
1972Year Built
2Stories
P5Building Class
R5DZoning
30,750 sfGross Floor Area
2Units
LL97 Covered1 Open Violation ▸FDNY Report ↗
Community center · Owner of record: 143-10 143RD LLC · 21,352 sf lot · 1.44 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionEquipmentGeneralOther
Roof9p · 2 filings · 13 docs
Floor 230p · 2 filings · 17 docs
Floor 129p · 3 filings · 20 docs
Cellar26p · 2 filings · 17 docs
Site & exterior8p · 3 filings · 8 docs
Filed — no permit issued17p · 3 filings · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MARKIS MANAGEMENT LLC2103/22/2026
METRO CONTRACTING NY1007/08/2026
143-10 143RD303/22/2026
WOLET ENTERPRISES303/21/2026
G-NET CONSTRUCTION103/22/2026
123-10 143RD103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S M EXPEDITING203/21/2026
N N CONSULTANT1203/21/2026
SAGACITY BUILDING SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
G-NET CONSTRUCTION CORPGeneral Contractor903/21/2026
METRO CONTRACTING NY, INC.General Contractor507/08/2026
DONE RIGHT HOOD & FIRE SAGeneral Contractor303/21/2026
SURE ELEC'L CONTR'G CORP.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
C.M. TESTING LABORATORY,1352202/29/2024
SOHAIL HUMAYUN P E INC8457105/31/2023
VALERIO ASSOCIATES, P.C.1379109/27/2022
LONGTIN SOLUTIONS LLC8320104/21/2022
Building Lifecycle
All (103)Filed (10)Permit Issued (8)Signed Off (3)Violation (26)Inspection (1)Objection (38)Special Inspection (17)
01/08/2026
Violation issued (FDNY_ORDER, closed)
01/08/2026
Violation issued (FDNY_ORDER, closed)
01/08/2026
Violation issued (FDNY_ORDER, closed)
01/08/2026
Violation issued (FDNY_ORDER, closed)
01/08/2026
Violation issued (FDNY_ORDER, closed)
01/08/2026
Violation issued (FDNY_ORDER, closed)
12/04/2024
Violation issued (FDNY_NOV, closed)
03/13/2024
Signed off — Alteration
FILING HEREWITH APPLICATION FOR MECHANICAL WORK TYPE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00718383-I1
03/13/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/12/2024
Special inspection requirement — Final
JOHN SEMIOLI
03/12/2024
Special inspection requirement — Fire-Resistance Rated Construction
JOHN SEMIOLI
03/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOHN SEMIOLI
03/12/2024
Special inspection requirement — Mechanical Systems
JOHN SEMIOLI
03/12/2024
Special inspection requirement — Energy Code Compliance Inspections
JOHN SEMIOLI
02/29/2024
Filed — Alteration
FILING HEREWITH APPLICATION FOR MECHANICAL WORK TYPE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00718383-P1
12/12/2023
Signed off — Alteration
Install commercial kitchen exhaust system and make up air for 1st floor space.
Q00874188-I1
11/16/2023
Permit issued — Mechanical Systems
Q00718383-I1-MS
10/04/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/15/2023
Permit issued — Supported Scaffold
Q08005526-I1-SF
07/26/2023
Violation issued (FDNY_ORDER, closed)
07/26/2023
Violation issued (FDNY_NOV, closed)
07/21/2023
Permit issued — Sidewalk Shed
Q00782351-I1-SH
06/20/2023
Permit issued — Mechanical Systems
Q00874188-I1-MS
05/31/2023
Filed — Alteration
Install commercial kitchen exhaust system and make up air for 1st floor space.
Q00874188-I1
05/05/2023
Objection resolved — Addressed
05/05/2023
Objection resolved — Addressed
05/05/2023
Objection resolved — Addressed
05/05/2023
Objection resolved — Addressed
05/05/2023
Objection resolved — Addressed
03/17/2023
Signed off — Alteration
Q08006797-I1
02/27/2023
Violation issued (FDNY_NOV, closed)
10/14/2022
Permit issued — General Construction
Q08006797-I1-GC
09/27/2022
Filed — Alteration
Q08006797-I1
09/25/2022
Violation issued (FDNY_NOV, closed)
09/20/2022
Special inspection requirement — Final
Nicholas Pappas
09/20/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOHN VALERIO
09/19/2022
Permit issued — Supported Scaffold
Q08005526-I1-SF
09/17/2022
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
Q08005526-I1
07/27/2022
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
Q00782351-I1
07/27/2022
Permit issued — Sidewalk Shed
Q00782351-I1-SH
07/27/2022
Permit issued — General Construction
Q00602231-I1-GC
07/21/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/21/2022
Violation issued (ECB, closed)
Construction
04/27/2022
Objection raised — Inspections
04/27/2022
Objection resolved — Addressed
04/27/2022
Objection raised — Energy
04/27/2022
Objection resolved — Addressed
04/27/2022
Objection raised — Other
04/27/2022
Objection resolved — Addressed
04/26/2022
Objection raised — Structural
04/26/2022
Objection resolved — Addressed
04/26/2022
Objection raised — Structural
04/26/2022
Objection resolved — Addressed
04/26/2022
Objection raised — Energy
04/26/2022
Objection resolved — Addressed
04/21/2022
Filed — Alteration
FILING HEREWITH APPLICATION FOR MECHANICAL WORK TYPE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00718383-I1
04/21/2022
Filed — Alteration
FILING HEREWITH APPPLICATION FOR PLUMBING AND SPRINKLER WORK TYPES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q00720203-I1
04/20/2022
Filed — Alteration
FILING HEREWITH APPLICATION FOR INTERIOR RENOVATIONS THROUGHTOUT. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q00602231-I1
04/16/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
04/16/2022
Special inspection requirement — Sprinkler Systems
TIM TSAI
Latest 60 of 103 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offG-NET CONSTRUCTION CORP11/16/2023
DOB NOWSupported ScaffoldPermit IssuedMETRO CONTRACTING NY, INC.09/15/2023
DOB NOWSidewalk ShedPermit IssuedMETRO CONTRACTING NY, INC.07/21/2023
DOB NOWMechanical SystemsSigned-offDONE RIGHT HOOD & FIRE SA06/20/2023
DOB NOWGeneral ConstructionSigned-offG-NET CONSTRUCTION CORP10/14/2022
DOB NOWSupported ScaffoldPermit IssuedMETRO CONTRACTING NY, INC.09/19/2022
DOB NOWSidewalk ShedPermit IssuedMETRO CONTRACTING NY, INC.07/27/2022
DOB NOWGeneral ConstructionPermit IssuedG-NET CONSTRUCTION CORP07/27/2022
BIS—ISSUED123-10 143RD LLC02/13/2015
BIS—ISSUEDWOLET ENTERPRISES04/01/2005
BISMHISSUEDAIR STREAM AIR CONDITIONING02/06/2001
BISPLISSUEDVITELLO P & MECHANICAL INC12/04/2000
BISOTISSUEDWOLET CONSTRUCTION INC10/17/2000
BISOTISSUEDWOLET CONSTRUCTION INC09/11/2000
BISPLISSUEDA-1 WATERMAIN & SEWER03/23/2000
BIS—ISSUEDWOLT ENTERPRISES07/12/1999
BISOTISSUEDWOLET CONSTRUCTION CORP01/10/1994
BISFPISSUEDLUND FIRE PRODUCTS CO01/06/1994
BISMHISSUEDDELPHI MECHANICAL INC09/29/1993
1 project · most recent 04/21/2022
FiledStatusContractorScope
04/21/2022———
1 project · most recent 04/21/2022
Water/Sanitary
FiledStatusContractorScope
04/21/2022——Water/Sanitary
4 projects · most recent 08/23/2023
General Wiring
FiledStatusContractorScope
08/23/2023Permit IssuedBAY ELECTRIC INC.General Wiring
11/11/2022CompleteSURE ELEC'L CONTR'G CORP.General Wiring
07/29/2022CompleteRICHARD NEU—
05/20/2022Permit IssuedJAM ELECTRICAL CORP—
2 projects · most recent 09/17/2022
Scaffold Sidewalk Shed
FiledStatusContractorScope
09/17/2022Permit IssuedMETRO CONTRACTING NY, INCScaffold
07/27/2022Permit IssuedMETRO CONTRACTING NY, INCSidewalk Shed
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/13/2024Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
03/12/2024FinalJOHN SEMIOLIprogress
03/12/2024Fire-Resistance Rated ConstructionJOHN SEMIOLIprogress
03/12/2024Fire-Resistant Penetrations and JointsJOHN SEMIOLIspecial
03/12/2024Mechanical SystemsJOHN SEMIOLIspecial
03/12/2024Energy Code Compliance InspectionsJOHN SEMIOLIprogress
09/20/2022FinalNicholas Pappasprogress
09/20/2022Structural Stability – Alterations of existing buildingsJOHN VALERIOspecial
04/16/2022Fire-Resistant Penetrations and JointsTIM TSAIspecial
04/16/2022Sprinkler SystemsTIM TSAIspecial
03/19/2022Insulation placement and R valuesRyan Minenergy_progress
03/19/2022Interior lighting powerRyan Minenergy_progress
03/19/2022VestibulesRyan Minenergy_progress
03/19/2022Exterior lighting powerRyan Minenergy_progress
03/19/2022Lighting controlsRyan Minenergy_progress
12/14/2021Public Assembly Emergency Lighting—progress
12/14/2021Public Assembly Emergency Lighting—progress
09/28/2021FinalJOHN SEMIOLIprogress
▾Documents — 65 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch8
08/26/2026Q00782351-I1Request digital key ↗
08/25/2026Q08005526-I1Request digital key ↗
08/25/2026Q08006797-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly2
08/26/2026Q00647854-I1Request digital key ↗
08/15/2026Q00647866-I1Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION8
10/06/2022420972120Open ↗
08/09/2018420972120Open ↗
04/24/2018420972120Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
03/07/2015420972120Open ↗
▸BISWORK PERMIT APPLICATION1
03/07/2015420972120Open ↗
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/26/2026Q00647866-I1Open ↗
08/26/2026Q00647854-I1Open ↗
08/13/2026Q00602231-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/02/2026Q00718383-I1Open ↗
09/01/2026Q00602231-I1Open ↗
09/01/2026Q00602231-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026Q00718383-I1Open ↗
08/25/2026Q00720203-I1Open ↗
08/24/2026Q08006797-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION2
02/19/2015420972120Open ↗
09/12/2018420972120Open ↗
▸Trade Schedules & Equipment1
▸BISFA - FDNY APPROVAL : FD-FAA1
11/13/2023421222144Open ↗
▸Safety & Tenant Protection1
▸BISST-1 Street Tree Checklist1
02/19/2015420972120Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00874188-I1Open ↗
08/13/2026Q00602231-I1Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/13/2026Q00720203-I1Open ↗
08/13/2026Q00718383-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/30/2015421222144Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/12/2018420972120Open ↗
▸BISTR8: Energy Code Progress Inspections1
02/19/2015420972120Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00602231-I1Open ↗
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION3
12/11/2014420972120Open ↗
12/11/2014420972120Open ↗
12/11/2014420972120Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
04/24/2014420972120Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
04/24/2014420972120Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/30/2015421222144Open ↗
02/19/2015420972120Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
11/30/2015421222144Open ↗
04/24/2014420972120Open ↗
▸BISBOROUGH INTAKE FORM1
04/24/2018420972120Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM1
04/24/2014420972120Open ↗
▸DOB NOWAlternate Plan 11