← Back
Three families
123 ST MARKS AVENUE
BROOKLYN · BIN 3028074
💬 Discuss this project
1872Year Built
3Stories
C0Building Class
R6BZoning
2,935 sfGross Floor Area
3Units
5 Open Violations ▸FDNY Report ↗
Three families · 3,092 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingCivil
Permit Issued — active, not yet Signed-off
Floor 2Under Construction34p · 1 filing · 20 docs
Floor 1Under Construction36p · 2 filings · 20 docs
CellarUnder Construction38p · 2 filings · 20 docs
Sub-BasementUnder Construction36p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
XIA CONSTRUCTION MNGMT303/22/2026
OWNER OF123 ST MARKS AVE103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SA-DA ARCHITECTURE507/22/2026
KZ ENGINEERING, P.C206/30/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XIA CONSTRUCTION MNGMT*General Contractor606/28/2026
S & L PLUMBING INCPlumbing207/02/2026
CL ELECTRICAL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SA-DA ARCHITECTURE2640309/12/2025
KZ ENGINEERING, P.C.4665206/30/2025
TRIANGLE INSPECTION & TES7495206/30/2025
Building Lifecycle
All (90)Filed (7)Permit Issued (6)Violation (6)Inspection (3)Objection (38)Special Inspection (30)
07/22/2026
Filed — Alteration
MECHANICAL WORK TO CELLAR, BASEMENT, AND 1ST FLOOR OF A FOUR STORY TWO FAMILY BUILDING. ALTERATIONS TO CONSIST OF THE INSTALLATION OF NEW HVAC SYSTEM AND EXHAUST VENTS. NO CHANGE TO ZONING, USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01153247-P3
07/02/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/02/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/02/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/30/2026
Permit issued — Plumbing
B01153247-S1-PL
09/25/2025
Objection resolved — Addressed
09/25/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Alexander Stoltz
09/25/2025
Special inspection requirement — Insulation placement and R values
Alexander Stoltz
09/25/2025
Special inspection requirement — Exterior lighting power
Alexander Stoltz
09/25/2025
Special inspection requirement — Fenestration areas
Alexander Stoltz
09/25/2025
Special inspection requirement — Fenestration air leakage
Alexander Stoltz
09/25/2025
Special inspection requirement — Lighting in dwelling units
Alexander Stoltz
09/25/2025
Special inspection requirement — Lighting controls
Alexander Stoltz
09/25/2025
Special inspection requirement — Air barrier - visual inspection
Alexander Stoltz
09/25/2025
Special inspection requirement — Final
Alexander Stoltz
09/25/2025
Special inspection requirement — Fire-Resistance Rated Construction
Alexander Stoltz
09/25/2025
Special inspection requirement — Energy Code Compliance Inspections
Alexander Stoltz
09/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Stoltz
09/22/2025
Objection raised — Scope
09/12/2025
Filed — Alteration
MECHANICAL WORK TO CELLAR, BASEMENT, AND 1ST FLOOR OF A FOUR STORY TWO FAMILY BUILDING. ALTERATIONS TO CONSIST OF THE INSTALLATION OF NEW HVAC SYSTEM AND EXHAUST VENTS. NO CHANGE TO ZONING, USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01153247-P1
09/08/2025
Special inspection requirement — Energy Code Compliance Inspections
Alexander Stoltz
09/08/2025
Special inspection requirement — Fire-Resistance Rated Construction
Alexander Stoltz
09/08/2025
Special inspection requirement — Fenestration air leakage
Alexander Stoltz
09/08/2025
Special inspection requirement — Lighting controls
Alexander Stoltz
09/08/2025
Special inspection requirement — Fenestration areas
Alexander Stoltz
09/08/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Alexander Stoltz
09/08/2025
Special inspection requirement — Lighting in dwelling units
Alexander Stoltz
09/08/2025
Special inspection requirement — Insulation placement and R values
Alexander Stoltz
09/08/2025
Special inspection requirement — Air barrier - visual inspection
Alexander Stoltz
09/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Stoltz
09/08/2025
Special inspection requirement — Exterior lighting power
Alexander Stoltz
09/08/2025
Special inspection requirement — Final
Alexander Stoltz
09/05/2025
Violation issued (ECB, open)
Unknown
09/05/2025
Violation issued (ECB, open)
Unknown
09/05/2025
Violation issued (ECB, open)
Construction
09/05/2025
Violation issued (ECB, open)
Construction
08/27/2025
Permit issued — General Construction
B01153247-I1-GC
07/22/2025
Permit issued — Earth Work
B01163345-I1-GC-CX
07/08/2025
Special inspection requirement — Final
Karol Zdancewicz
07/08/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Rajasekhar Sakhamuri
07/08/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Karol Zdancewicz
07/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Karol Zdancewicz
07/08/2025
Special inspection requirement — Structural Steel - Details
Karol Zdancewicz
07/08/2025
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
06/30/2025
Filed — Alteration
PROVIDE STRUCTURAL DESIGN FOR THE BUILDING RENOVATION AT THE REFERENCED ADDRESS. CONSTRUCTION INCLUDES PROVIDING FOUNDATION FOR 1ST FLOOR ADDITION, STEEL FRAMING FOR 1ST FLOOR ROOF DECK AND STEEL STAIRS
B01163345-P1
06/05/2025
Permit issued — General Construction
B01153247-I1-GC
06/04/2025
Objection resolved — Addressed
06/02/2025
Objection raised — Scope
05/22/2025
Objection raised — Scope
05/22/2025
Objection resolved — Addressed
05/14/2025
Objection resolved — Addressed
05/14/2025
Objection resolved — Addressed
05/14/2025
Objection resolved — Addressed
05/14/2025
Objection resolved — Addressed
05/09/2025
Permit issued — Plumbing
B01153247-S1-PL
05/02/2025
Permit issued — Mechanical Systems
B01153247-S2-MS
05/01/2025
Objection raised — Admin
05/01/2025
Objection raised — Structural
05/01/2025
Objection raised — Structural
05/01/2025
Objection raised — Structural
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedS & L PLUMBING INC06/30/2026
DOB NOWGeneral ConstructionPermit IssuedXIA CONSTRUCTION MNGMT*08/27/2025
DOB NOWEarth WorkPermit IssuedXIA CONSTRUCTION MNGMT*07/22/2025
DOB NOWGeneral ConstructionPermit IssuedXIA CONSTRUCTION MNGMT*06/05/2025
DOB NOWPlumbingPermit IssuedS & L PLUMBING INC05/09/2025
DOB NOWMechanical SystemsPermit IssuedXIA CONSTRUCTION MNGMT*05/02/2025
BISOTISSUEDA K AZAD DBA AZAD CONTRACTING CO04/20/2001
1 job · most recent 07/22/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/22/2026Permit IssuedXIA CONSTRUCTION MNGMT*Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin RXTQ48TAVJU 45,500 BTU · Vrf Outdoor ×2
Ventilation
Greenheck N/A 100 CFM ×4
1 job · most recent 07/22/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/22/2026Permit IssuedCASE PLUMBING LLCGas, Storm, Water/Sanitary
1 job · most recent 06/30/2025
General Wiring
FiledStatusContractorScope
06/30/2025Permit IssuedCL ELECTRICAL CORPGeneral Wiring
1 job · most recent 06/30/2025
Steel Concrete Masonry
FiledStatusContractorScope
06/30/2025Permit IssuedXIA CONSTRUCTION MNGMT*Steel, Concrete, Masonry
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/02/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/02/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/02/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 55
DateRequirementInspectorRole
09/25/2025Fenestration and door U-factor and product ratingsAlexander Stoltzenergy_progress
09/25/2025Insulation placement and R valuesAlexander Stoltzenergy_progress
09/25/2025Exterior lighting powerAlexander Stoltzenergy_progress
09/25/2025Fenestration areasAlexander Stoltzenergy_progress
09/25/2025Fenestration air leakageAlexander Stoltzenergy_progress
09/25/2025Lighting in dwelling unitsAlexander Stoltzenergy_progress
09/25/2025Lighting controlsAlexander Stoltzenergy_progress
09/25/2025Air barrier - visual inspectionAlexander Stoltzenergy_progress
09/25/2025FinalAlexander Stoltzprogress
09/25/2025Fire-Resistance Rated ConstructionAlexander Stoltzprogress
09/25/2025Energy Code Compliance InspectionsAlexander Stoltzprogress
09/25/2025Fire-Resistant Penetrations and JointsAlexander Stoltzspecial
09/08/2025Energy Code Compliance InspectionsAlexander Stoltzprogress
09/08/2025Fire-Resistance Rated ConstructionAlexander Stoltzprogress
09/08/2025Fenestration air leakageAlexander Stoltzenergy_progress
09/08/2025Lighting controlsAlexander Stoltzenergy_progress
09/08/2025Fenestration areasAlexander Stoltzenergy_progress
09/08/2025Fenestration and door U-factor and product ratingsAlexander Stoltzenergy_progress
09/08/2025Lighting in dwelling unitsAlexander Stoltzenergy_progress
09/08/2025Insulation placement and R valuesAlexander Stoltzenergy_progress
09/08/2025Air barrier - visual inspectionAlexander Stoltzenergy_progress
09/08/2025Fire-Resistant Penetrations and JointsAlexander Stoltzspecial
09/08/2025Exterior lighting powerAlexander Stoltzenergy_progress
09/08/2025FinalAlexander Stoltzprogress
07/08/2025FinalKarol Zdancewiczprogress
Latest 25 of 55.
▾Documents — 109 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/22/2026B01153247-S1Request digital key ↗
08/22/2026B01153247-S2Request digital key ↗
08/22/2026B01153247-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits7
▸DOB NOWLPC Approval/Permit7
08/22/2026B01153247-I1Open ↗
08/22/2026B01153247-P3Open ↗
08/13/2026B01153247-S1Open ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZD1: DOB Zoning Diagram4
08/22/2026B01153247-I1Open ↗
08/13/2026B01163345-I1Open ↗
08/13/2026B01163345-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/22/2026B01153247-I1Open ↗
08/13/2026B01163345-I1Open ↗
08/13/2026B01163345-P1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications63
▸DOB NOWProgress Inspector Seal & Signature32
08/27/2026B01153247-P1Open ↗
08/27/2026B01153247-P1Open ↗
08/27/2026B01153247-P1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature23
08/27/2026B01153247-P1Open ↗
08/26/2026B01163345-I1Open ↗
08/26/2026B01163345-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/22/2026B01153247-I1Open ↗
08/22/2026B01153247-P3Open ↗
08/22/2026B01153247-S1Open ↗
Showing 3 of 8 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/22/2026B01153247-I1Open ↗
08/13/2026B01153247-P1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/22/2026B01153247-I1Open ↗
08/22/2026B01153247-P3Open ↗
08/21/2026B01163345-I1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents15
▸DOB NOWSite Survey: Initial4
08/22/2026B01153247-I1Open ↗
08/13/2026B01153247-P1Open ↗
08/13/2026B01163345-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/22/2026B01153247-I1Open ↗
08/13/2026B01163345-P1Open ↗
08/13/2026B01163345-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/22/2026B01153247-I1Open ↗
08/13/2026B01163345-P1Open ↗
08/13/2026B01153247-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWEvaluation of Adjacent Building Report (BC 1817.3)2
08/13/2026B01163345-I1Open ↗
08/13/2026B01163345-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B01163345-I1Open ↗