← Back
BuildNYC
Office with commercial, 1-6 stories
131 ESSEX STREET
MANHATTAN · Lower East Side · BIN 1005379
💬 Discuss this project
1920Year Built
6Stories
O5Building Class
C4-4AZoning
12,015 sfGross Floor Area
7Units
4 Active Violations ▸FDNY Report ↗
Office with commercial, 1-6 stories · Owner of record: B. Arnold · 1,780 sf lot · 6.75 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentLandscapeGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofStreamline Building Management LLC25p · 6 filings · 20 docs
Floor 6B Arnold LLC29p · 4 filings · 20 docs
Floor 5B Arnold LLC31p · 4 filings · 20 docs
Floor 4B Arnold LLC29p · 4 filings · 20 docs
Floor 3B Arnold LLC31p · 4 filings · 20 docs
Floor 2Streamline Building Management LLC40p · 5 filings · 20 docs
Floor 1Streamline Building Management LLCUnder Construction75p · 8 filings · 20 docs
CellarStreamline Building Management LLCUnder Construction85p · 8 filings · 20 docs
Site & exteriorB Arnold LLC13p · 3 filings · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
B Arnold5207/08/2026
Pulperia103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Concessi Engineering105/02/2025
EP Engineering411/10/2023
James Chai Architect308/30/2023
Build Tech Architects304/11/2023
William F. Ryan, Jr. P.E512/16/2021
KZ Engineering411/29/2021
SRL Associates110/11/2021
Gilsanz Murray Steficek103/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Jenny Flores Expediting703/21/2026
HTX Building Consulting303/21/2026
Metropolis Group1203/21/2026
Synergy Building Consultants503/21/2026
Ganci Logozzo203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Arsenal ScaffoldScaffold507/08/2026
S TerranovaGeneral Contractor407/08/2026
Jpi Plumbing & HeatingPlumbing307/08/2026
Euro RemodelingGeneral Contractor207/08/2026
Expert Fire SprinklerFire Protection107/08/2026
Gil GlickPlumbing107/08/2026
Jpi Plumbing & HeatingFire Protection107/08/2026
RRP PlumbingFire Protection107/08/2026
F & L General ElectricElectrical103/22/2026
RRP PlumbingPlumbing107/08/2026
CoolbritsGeneral Contractor107/08/2026
Dve ConstructionGeneral Contractor107/08/2026
AMC Plumbing, Heating & CLNGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Concessi Engineering540205/02/2025
EP Inspections and Commis7079411/10/2023
SY Engineering5149108/30/2023
James JH Chai & Associate6481207/17/2023
Buildtech Engineering6369304/11/2023
Ryan Special Engineering2018612/16/2021
Building Lifecycle
All (141)Filed (22)Permit Issued (18)Signed Off (11)Violation (38)Inspection (10)Objection (12)Special Inspection (30)
10/18/2025
Violation issued (FDNY_NOV, closed)
08/06/2025
Signed off — Alteration
M01212457-I1
05/21/2025
Permit issued — Mechanical Systems
M01212457-I1-MS
05/02/2025
Filed — Alteration
M01212457-I1
12/02/2024
Violation issued (FDNY_NOV, closed)
09/24/2024
Violation issued (FDNY_NOV, closed)
04/18/2024
Permit issued — Sprinklers
M00848425-I1-PL
04/16/2024
Violation issued (FDNY_NOV, closed)
04/14/2024
Violation issued (FDNY_NOV, closed)
01/17/2024
Signed off — Alteration
Sub-filing SPRINKLER WORK FOR DENTAL OFFICE AT 2ND FLOOR; NO CHANGE USE, EGRESS OR OCCUPANCY.
M00900636-S3
01/17/2024
Signed off — Alteration
Sub-filing SPRINKLER WORK FOR DENTAL OFFICE AT 2ND FLOOR; NO CHANGE USE, EGRESS OR OCCUPANCY.
M00900636-I1
01/17/2024
Signed off — Alteration
Sub-filing SPRINKLER WORK FOR DENTAL OFFICE AT 2ND FLOOR; NO CHANGE USE, EGRESS OR OCCUPANCY.
M00900636-S1
01/17/2024
Violation issued (FDNY_NOV, closed)
12/29/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/27/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/27/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/29/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/28/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/10/2023
Filed — Alteration
HEREBY FILING FOR THE INSTALLATION OF PLUMBING FIXTURES/SPRINKLERS AT EXISTING COMMERCIAL SPACE. FILED IN CONJUNCTION WITH APPLICATION M00848406. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00848425-P3
11/02/2023
Filed — Alteration
HEREBY FILING FOR THE INSTALLATION OF PLUMBING FIXTURES/SPRINKLERS AT EXISTING COMMERCIAL SPACE. FILED IN CONJUNCTION WITH APPLICATION M00848406. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00848425-P2
11/02/2023
Violation issued (FDNY_NOV, closed)
10/23/2023
Permit issued — Plumbing
M00848425-I1-EW-SP
10/06/2023
Permit issued — Sprinklers
M00900636-S3-EW-SP
09/08/2023
Objection raised — Structural
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Scope
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Scope
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Structural
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Scope
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Scope
09/08/2023
Objection resolved — Addressed
09/07/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/30/2023
Filed — Alteration
Sub-filing SPRINKLER WORK FOR DENTAL OFFICE AT 2ND FLOOR; NO CHANGE USE, EGRESS OR OCCUPANCY.
M00900636-S3
08/29/2023
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND ASSOCIATED DUCTWORK FOR EATING/DRINKING ESTABLISHMENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00848459-P1
08/29/2023
Filed — Alteration
HEREBY FILING FOR THE INSTALLATION OF PLUMBING FIXTURES/SPRINKLERS AT EXISTING COMMERCIAL SPACE. FILED IN CONJUNCTION WITH APPLICATION M00848406. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00848425-P1
08/29/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
08/29/2023
Special inspection requirement — Final
Christopher Burgess
08/29/2023
Special inspection requirement — Shutoff dampers
Christopher Burgess
08/29/2023
Special inspection requirement — Maintenance information
Christopher Burgess
08/29/2023
Special inspection requirement — Mechanical Systems
Luis Pichardo
08/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
08/29/2023
Special inspection requirement — Duct leakage testing, insulation and design
Christopher Burgess
08/29/2023
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Burgess
08/29/2023
Special inspection requirement — Post-installed Anchors
Luis Pichardo
08/29/2023
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Burgess
08/29/2023
Special inspection requirement — Energy Code Compliance Inspections
Christopher Burgess
08/24/2023
Special inspection requirement — Sprinkler Systems
SUNGBOM YI
08/14/2023
Special inspection requirement — Maintenance information
Christopher Burgess
08/14/2023
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Burgess
08/14/2023
Special inspection requirement — Post-installed Anchors
Christopher Burgess
08/14/2023
Special inspection requirement — Sprinkler Systems
Christopher Burgess
08/14/2023
Special inspection requirement — Maintenance information
Christopher Burgess
08/14/2023
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Burgess
08/14/2023
Special inspection requirement — Energy Code Compliance Inspections
Christopher Burgess
08/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
Latest 60 of 141 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCoolbrits05/21/2025
DOB NOWPlumbingPermit IssuedAMC Plumbing, Heating & CLNG04/18/2024
DOB NOWSprinklersPermit IssuedExpert Fire Sprinkler10/23/2023
DOB NOWSprinklersSigned-offRalph W. Landolfi JR10/06/2023
DOB NOWPlumbingSigned-offRRP Plumbing07/19/2023
DOB NOWGeneral ConstructionSigned-offDve Construction07/19/2023
DOB NOWMechanical SystemsPermit IssuedS Terranova04/19/2023
DOB NOWPlumbingPermit IssuedGil Glick04/19/2023
DOB NOWGeneral ConstructionPermit IssuedS Terranova04/06/2023
DOB NOWPlumbingSigned-offJpi Plumbing & Heating11/05/2021
DOB NOWConstruction FenceSigned-offArsenal Scaffold10/12/2021
DOB NOWSidewalk ShedSigned-offArsenal Scaffold08/11/2021
DOB NOWConstruction FenceSigned-offArsenal Scaffold08/11/2021
DOB NOWStructuralSigned-offEuro Remodeling03/26/2021
DOB NOWSprinklersSigned-offJpi Plumbing & Heating11/23/2020
DOB NOWPlumbingSigned-offJpi Plumbing & Heating10/26/2020
DOB NOWPlumbingSigned-offJpi Plumbing & Heating10/15/2020
DOB NOWMechanical SystemsSigned-offEuro Remodeling10/15/2020
BIS—ISSUEDB.arnold08/23/2021
BISOTISSUEDEuro Remodeling03/25/2021
BISOTISSUEDEuro Remodeling06/15/2020
BISOTISSUEDEuro Remodeling11/19/2019
BISEQISSUEDCerina General Contracting06/13/2013
BISEQISSUEDCerina General Contracting06/12/2013
BISPLISSUEDChamp Plumbing & Heating11/13/2012
BISOTISSUEDAlbert Mendoza10/19/2012
BISEQISSUEDTrident Structural01/11/2010
BISOTISSUEDTrident Structural01/11/2010
BISEQISSUEDTrident Structural11/20/2009
BISOTISSUEDTrident Structural08/13/2009
1 project · most recent 08/29/2023
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/29/2023Permit IssuedS TerranovaAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric PKFY-P18NLMU-E 438 CFM · Vrf Indoor ×3
PUMY-P60NKMU3 60,000 BTU · Vrf Outdoor ×3
1 project · most recent 11/10/2023
FiledStatusContractorScope
11/10/2023Permit IssuedExpert Fire Sprinkler112 heads
1 project · most recent 11/10/2023
Gas Water/Sanitary
FiledStatusContractorScope
11/10/2023Permit IssuedA-1 Undergrnd Plumbing ConGas, Water/Sanitary
12 projects · most recent 11/18/2025
General Wiring
FiledStatusContractorScope
11/18/2025CompleteFusion Electl Contrng1 meters
11/18/2025CompleteFusion Electl ContrngGeneral Wiring
11/18/2025CompleteFusion Electl Contrng1 meters
11/18/2025CompleteFusion Electl ContrngGeneral Wiring
11/18/2025CompleteFusion Electl ContrngGeneral Wiring
04/27/2025Permit IssuedNash Electric ServicesGeneral Wiring
07/20/2023CompleteR & T ElectricalGeneral Wiring
04/20/2023Permit IssuedMartin DorkinGeneral Wiring
04/11/2022CompleteA.S.H. ElectricGeneral Wiring
04/08/2022CompleteLeader Electric CoGeneral Wiring
11/09/2021CompleteRoney Electric—
12/02/2018Permit IssuedF & L General ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
12/29/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/27/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/27/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/29/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/28/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/07/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/07/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/07/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/07/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 74
DateRequirementInspectorRole
08/29/2023Duct leakage testing, insulation and designChristopher Burgessenergy_progress
08/29/2023Energy Code Compliance InspectionsChristopher Burgessprogress
08/29/2023Fire-Resistant Penetrations and JointsLuis Pichardospecial
08/29/2023Mechanical SystemsLuis Pichardospecial
08/29/2023Post-installed AnchorsLuis Pichardospecial
08/29/2023FinalChristopher Burgessprogress
08/29/2023Shutoff dampersChristopher Burgessenergy_progress
08/29/2023HVAC-R and service water heating equipmentChristopher Burgessenergy_progress
08/29/2023Maintenance informationChristopher Burgessenergy_progress
08/29/2023HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
08/29/2023HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
08/24/2023Sprinkler SystemsSUNGBOM YIspecial
08/14/2023Sprinkler SystemsChristopher Burgessspecial
08/14/2023HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
08/14/2023HVAC-R and service water heating equipmentChristopher Burgessenergy_progress
08/14/2023Maintenance informationChristopher Burgessenergy_progress
08/14/2023HVAC-R and service water heating equipmentChristopher Burgessenergy_progress
08/14/2023Maintenance informationChristopher Burgessenergy_progress
08/14/2023HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
08/14/2023Duct leakage testing, insulation and designChristopher Burgessenergy_progress
08/14/2023HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
08/14/2023Shutoff dampersChristopher Burgessenergy_progress
08/14/2023Fire-Resistant Penetrations and JointsChristopher Burgessspecial
08/14/2023Post-installed AnchorsChristopher Burgessspecial
08/14/2023HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
Latest 25 of 74.
▾Documents — 226 on file (BIS + DOB NOW)
▸Plans & Drawings23
▸DOB NOWPlans/Sketch18
09/04/2026M00483414-I1Request digital key ↗
09/03/2026M00565899-I1Request digital key ↗
09/03/2026M00565899-P1Request digital key ↗
Showing 3 of 18 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems2
09/04/2026M00401356-I1Request digital key ↗
09/04/2026M00401356-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
09/04/2026M00406117-P1Request digital key ↗
09/04/2026M00406117-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
09/04/2026M00406116-I1Request digital key ↗
▸Applications & Permits32
▸BISPLAN / WORK APPROVAL APPLICATION16
04/14/2022140905812Open ↗
04/12/2022140905812Open ↗
06/16/2021123908664Open ↗
Showing 3 of 16 on file for this type
▸BISWORK PERMIT APPLICATION12
08/23/2021123908664Open ↗
03/25/2021140959540Open ↗
06/15/2020140905812Open ↗
Showing 3 of 12 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
05/09/2013120205811Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/16/2022123908664Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
03/25/2021140959540Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
03/25/2021140959540Open ↗
▸Seals & Professional Certifications88
▸DOB NOWProgress Inspector Seal & Signature26
09/01/2026M00900636-S1Open ↗
09/01/2026M00401356-I1Open ↗
09/01/2026M00401356-I1Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature23
09/04/2026M00406117-P1Open ↗
09/04/2026M00406117-I1Open ↗
09/04/2026M00483414-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature17
09/01/2026M00900636-S1Open ↗
09/01/2026M00401356-I1Open ↗
09/01/2026M00401356-I1Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
11/19/2019123409819Open ↗
11/14/2019123409819Open ↗
04/01/2013110205073Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
06/04/2020140905812Open ↗
11/14/2019123409819Open ↗
06/12/2013140086948Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
11/14/2019123409819Open ↗
10/22/2012121417252Open ↗
11/19/2009120205811Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
06/04/2020140905812Open ↗
06/12/2013140086948Open ↗
06/12/2013140086920Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
06/04/2020140905812Open ↗
06/12/2013140086948Open ↗
06/12/2013140086920Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
10/22/2012121417252Open ↗
11/19/2009120205811Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/09/2020140959540Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
10/22/2012121417252Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
07/26/2021123908664Open ↗
▸BISSTREET TREE SIGNOFF1
01/28/2025123908664Open ↗
▸Environmental & Asbestos24
▸DOB NOWDEP ACP-5: Asbestos Assessment Report19
09/04/2026M00406117-I1Open ↗
09/04/2026M00406117-P1Open ↗
09/04/2026M00483414-I1Open ↗
Showing 3 of 19 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
10/09/2020140959540Open ↗
06/04/2020140905812Open ↗
06/12/2013140086948Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
11/19/2009120205811Open ↗
▸Energy Compliance11
▸BISAS-BUILT ENERGY ANALYSIS (EN2)3
06/06/2022140905812Open ↗
03/21/2022140959540Open ↗
10/15/2020123409819Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
10/09/2020140959540Open ↗
06/15/2020140905812Open ↗
06/04/2020140905812Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/19/2019123409819Open ↗
10/22/2012121417252Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
06/12/2013140086920Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
06/06/2022140905812Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/04/2020140905812Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY5
10/09/2020140959540Open ↗
06/15/2020140905812Open ↗
06/04/2020140905812Open ↗
Showing 3 of 5 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
03/25/2021140959540Open ↗
▸Approvals, Objections & Sign-offs14
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
06/08/2022140905812Open ↗
03/22/2022140959540Open ↗
10/22/2020123409819Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
10/16/2015121417252Open ↗
11/19/2009120205811Open ↗
06/26/2008110205073Open ↗
▸BISFINAL3
06/06/2022140905812Open ↗
03/21/2022140959540Open ↗
10/22/2020123409819Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
07/26/2021123908664Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT7
07/26/2021123908664Open ↗
10/09/2020140959540Open ↗
06/04/2020140905812Open ↗
Showing 3 of 7 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW33
06/06/2022140905812Open ↗
03/21/2022140959540Open ↗
10/15/2020123409819Open ↗
▸Filing & Intake Forms14
▸BISEFILING COVER SHEET5
06/16/2021123908664Open ↗
11/14/2019123409819Open ↗
10/22/2012121417252Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION5
04/14/2022140905812Open ↗
07/26/2021123908664Open ↗
02/01/2021140959540Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
10/09/2020140959540Open ↗
06/04/2020140905812Open ↗
06/12/2013140086948Open ↗
Showing 3 of 4 on file for this type
▸Other Documents1
▸BISPLOT DIAGRAM1
07/26/2021123908664Open ↗