← Back
Elevator co-op, conversion from loft/warehouse
141 WOOSTER STREET
MANHATTAN · BIN 1008015
💬 Discuss this project
1896Year Built
8Stories
D0Building Class
M1-5/R7XZoning
54,600 sfGross Floor Area
33Units
LL97 CoveredRent Stabilized7 Open Violations ▸FISP: SAFE
Elevator co-op, conversion from loft/warehouse · Owner of record: GOOD DEAL RLTY CORP · 7,500 sf lot · 7.28 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction17p · 2 filings · 18 docs
Floor 89p · 1 filing · 6 docs
Floor 7
Floor 6
Floor 52p · 1 filing · 5 docs
Floor 41p · 1 filing · 14 docs
Floor 31p · 1 filing · 8 docs
Floor 25p · 3 filings · 18 docs
Floor 1
Cellar13p · 3 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AARCO CONTRACTING808/04/2026
AXIO PROPERTY MANAGEMENT107/08/2026
BOARD PRESIDENT907/08/2026
DIA ART FOUNDATION1307/08/2026
DERMER MANAGEMENT2203/22/2026
GOOD DEAL REALTY7603/22/2026
OWNER OF PREMISES 141 WOO103/22/2026
GOOD DEAL REALTY CP203/22/2026
LUBARSKY103/22/2026
SIERRA ASSETS GROUP LT103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
UNITED SAFETY CONSULTANTS303/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
JAM CONSULTANTS, INC.1203/21/2026
DOMANI CONSULTING203/21/2026
ARSENAL BUILDING CONSULTANTS LLC403/21/2026
J CALLAHAN CONSULTING603/21/2026
JM ZONING, LLC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPRING SCAFFOLDING LLCGeneral Contractor1907/08/2026
AARCO CONTRACTING LLCGeneral Contractor808/04/2026
EUROSTRUCT INCGeneral Contractor607/08/2026
SKYLINE RESTORATION INCGeneral Contractor603/21/2026
NATIONWIDE MECHANICAL INCPlumbing507/08/2026
PRO STAR PLBG,HTG&MECH INPlumbing307/08/2026
LOFT CONTRACTING NEW YORKGeneral Contractor203/21/2026
ALL PRO PLBG & HTG INCFire Protection207/08/2026
NATIONWIDE MECHANICAL INCFire Protection207/08/2026
HAMILTON AIR COMPANY, INC.General Contractor203/21/2026
PALONE BROTHERS AIRGeneral Contractor107/08/2026
EIS ELECTRIC CORP DBAElectrical103/22/2026
ALL HOUR SEWER SERVICE CO.Plumbing107/08/2026
ALL PRO PLBG & HTG INCPlumbing107/08/2026
DELTA-SIGMA MECH CORPPlumbing107/08/2026
LUND FIRE PRODUCTS CO INCFire Protection107/08/2026
FIVE BORO ASSOCIATES INCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KATZ ARCHITECTURE1371104/23/2026
H & O ENGINEERING, DPC5595202/06/2024
HUGH ROBOTHAM, ARCHITECT,962102/06/2024
ALAN MARGOLIN & ASSOC423506/12/2023
COLLADO ENGINEERING, DPC3432102/01/2023
TAN ENGINEERING, P.C.1291106/30/2022
CHARLES G MICHEL ENGINEER2871407/23/2021
EUGENE KHANANOV ARCHITECT2816302/04/2021
ALTERA ENGINEERING2646211/09/2020
Building Lifecycle
All (227)Filed (29)Permit Issued (40)Signed Off (16)Facade (FISP) (21)Violation (60)Inspection (21)Objection (10)Special Inspection (30)
08/31/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/31/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/03/2026
Permit issued — Sidewalk Shed
M01394433-I1-SH
06/01/2026
Permit issued — General Construction
M01059635-I1-GC
05/12/2026
Permit issued — Sidewalk Shed
M01394433-I1-SH
05/12/2026
Permit issued — Sidewalk Shed
M01394433-I1-SF
05/08/2026
Filed — Alteration
INSTALLATION OF 300PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CH #33 OF THE NYC CODE 2022. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M01394433-I1
05/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/23/2026
Filed — Alteration
THE REPLACEMENT OF THE EXISTING ROOF MEMBRANE ASSEMBLIES WITH A NEW MULTI-PLY MODIFIED BITUMEN ROOFING MEMBRANE SYSTEM, NEW FLASHING, BRICKWORK, AND THE INSTALLATION OF NEW RAILINGS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01059635-I1
04/20/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/15/2026
Special inspection requirement — Energy Code Compliance Inspections
David Katz
04/15/2026
Special inspection requirement — Insulation placement and R values
David Katz
04/15/2026
Special inspection requirement — Fire-Resistance Rated Construction
David Katz
04/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
David Katz
04/15/2026
Special inspection requirement — Masonry
David Katz
04/14/2026
Special inspection requirement — Tenant Protection Plan Compliance
David Katz
08/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/31/2025
Permit issued — Standpipe
M00687934-I1-PL
01/29/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/29/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/11/2024
Signed off — Alteration
Sidewalk shed installed per plans, no change in use, egress or occupancy
M00587746-I1
09/17/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/18/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
07/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/16/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/15/2024
Permit issued — Sprinklers
M00687934-I1-PL
07/15/2024
Permit issued — Standpipe
M00687934-I1-EW-SD
06/13/2024
Permit issued — Standpipe
M00687934-I1-EW-SP
06/13/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/11/2024
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
05/31/2024
Special inspection requirement — Final
David Katz
04/01/2024
Special inspection requirement — Fire-Resistance Rated Construction
Hugh Robotham
04/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hugh Robotham
03/27/2024
Permit issued — Plumbing
M35385727-I1-EW-SP
02/08/2024
Signed off — Alteration
Plumbing work as per plans. No change of use, egress or occupancy under this application.
M00337455-I1
02/06/2024
Filed — Alteration
M00665727-I1
01/31/2024
Special inspection requirement — Tenant Protection Plan Compliance
SANTIAGO HELMAN
11/01/2023
Cycle 9 facade report signed — SAFE
09/29/2023
Cycle 9 facade report submitted
09/20/2023
Signed off — Alteration
pipe scaffolding installed per plans, no change in use, egress or occupancy
M00587751-I1
09/01/2023
Permit issued — Sidewalk Shed
M00587746-I1-SH
08/17/2023
Cycle 9 facade inspection completed
08/04/2023
Cycle 9 facade report submitted
08/03/2023
Cycle 9 facade inspection completed
07/13/2023
Permit issued — Sprinklers
M00687934-I1-EW-SP
07/11/2023
Cycle 9 facade report signed — UNSAFE
06/21/2023
Signed off — Alteration
filing herewith for modifications to an existing sprinkler system
M00627510-I1
06/15/2023
Permit issued — Standpipe
M00687934-I1-EW-SD
06/15/2023
Permit issued — Plumbing
M00687934-I1-PL
06/12/2023
Filed — Alteration
filing herewith for modifications to an existing sprinkler system
M00627510-P2
06/12/2023
Special inspection requirement — Sprinkler Systems
Young Suh
05/17/2023
Signed off — Alteration
filing herewith for the installation of plumbing fixtures
M00627505-I1
05/04/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/25/2023
Signed off — Alteration
filing herewith for modifications to an existing HVAC system
M00627497-I1
04/24/2023
Signed off — Alteration
REMOVAL AND INSTALLATION OF INTERIOR NON LOAD BEARING PARTITIONS AND RELATED FINISHES
M00625863-I1
04/11/2023
Filed — Alteration
filing herewith for modifications to an existing sprinkler system
M00627510-P1
04/05/2023
Permit issued — Supported Scaffold
M00854430-I1-SF
04/04/2023
Filed — Alteration
M00854430-I1
03/30/2023
Permit issued — General Construction
M00625863-I1-GC
03/23/2023
Signed off — Alteration
M00504156-I1
Latest 60 of 227 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedAARCO CONTRACTING LLC08/03/2026
DOB NOWGeneral ConstructionPermit IssuedAARCO CONTRACTING LLC06/01/2026
DOB NOWSidewalk ShedPermit IssuedAARCO CONTRACTING LLC05/12/2026
DOB NOWSidewalk ShedPermit IssuedAARCO CONTRACTING LLC05/12/2026
DOB NOWStandpipePermit IssuedNATIONWIDE MECHANICAL INC07/31/2025
DOB NOWSprinklersPermit IssuedNATIONWIDE MECHANICAL INC07/15/2024
DOB NOWStandpipePermit IssuedNATIONWIDE MECHANICAL INC07/15/2024
DOB NOWStandpipePermit IssuedNATIONWIDE MECHANICAL INC06/13/2024
DOB NOWPlumbingPermit IssuedLUND FIRE PRODUCTS CO INC03/27/2024
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC09/01/2023
DOB NOWSprinklersPermit IssuedNATIONWIDE MECHANICAL INC07/13/2023
DOB NOWStandpipePermit IssuedNATIONWIDE MECHANICAL INC06/15/2023
DOB NOWPlumbingPermit IssuedNATIONWIDE MECHANICAL INC06/15/2023
DOB NOWSupported ScaffoldPermit IssuedAARCO CONTRACTING LLC04/05/2023
DOB NOWGeneral ConstructionSigned-offEUROSTRUCT INC03/30/2023
DOB NOWGeneral ConstructionSigned-offAARCO CONTRACTING LLC03/16/2023
DOB NOWGeneral ConstructionSigned-offSKYLINE RESTORATION INC02/16/2023
DOB NOWGeneral ConstructionSigned-offEUROSTRUCT INC11/29/2022
DOB NOWSprinklersSigned-offFIVE BORO ASSOCIATES INC09/16/2022
DOB NOWMechanical SystemsSigned-offEUROSTRUCT INC09/15/2022
DOB NOWPlumbingSigned-offPRO STAR PLBG,HTG&MECH IN09/03/2022
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC09/01/2022
DOB NOWSupported ScaffoldSigned-offSPRING SCAFFOLDING LLC09/01/2022
DOB NOWGeneral ConstructionSigned-offEUROSTRUCT INC08/19/2022
DOB NOWMechanical SystemsSigned-offLOFT CONTRACTING NEW YORK08/02/2022
DOB NOWGeneral ConstructionSigned-offSKYLINE RESTORATION INC07/29/2022
DOB NOWPlumbingSigned-offDELTA-SIGMA MECH CORP01/24/2022
DOB NOWSupported ScaffoldSigned-offSPRING SCAFFOLDING LLC09/07/2021
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC09/07/2021
DOB NOWGeneral ConstructionSigned-offSKYLINE RESTORATION INC08/10/2021
DOB NOWPlumbingSigned-offPRO STAR PLBG,HTG&MECH IN07/16/2021
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC04/06/2021
DOB NOWSupported ScaffoldSigned-offSPRING SCAFFOLDING LLC04/06/2021
DOB NOWMechanical SystemsSigned-offHAMILTON AIR COMPANY, INC.03/25/2021
DOB NOWMechanical SystemsSigned-offPALONE BROTHERS AIR02/19/2021
DOB NOWPlumbingSigned-offPRO STAR PLBG,HTG&MECH IN12/14/2020
DOB NOWSprinklersSigned-offALL PRO PLBG & HTG INC10/08/2020
DOB NOWPlumbingSigned-offALL HOUR SEWER SERVICE CO.09/10/2020
DOB NOWPlumbingSigned-offALL PRO PLBG & HTG INC02/28/2020
DOB NOWSprinklersSigned-offALL PRO PLBG & HTG INC02/04/2020
+ 50 more permits on file
1 project · most recent 11/09/2020
FiledStatusContractorScope
11/09/2020Signed-offALL PRO PLBG & HTG INC—
16 projects · most recent 06/03/2026
General Wiring
FiledStatusContractorScope
06/03/2026Permit IssuedJOSEPH WEINSTEIN ELECTRIC—
05/12/2026Permit IssuedRICHARD NEU—
07/18/2025CompleteVALLEY ELECTRIC OF NY INC—
06/26/2024CompleteE & M ELECTRICAL NY CORPGeneral Wiring
09/26/2023CompleteALBA ELECTRIC CORPGeneral Wiring
03/10/2023CompleteALBA ELECTRIC CORPGeneral Wiring
12/19/2022CompleteTHE METRO GROUP ELECTRICGeneral Wiring
10/24/2022Permit IssuedP&H ELECT D/B/A MAGE ELEC—
08/03/2021CompleteRESPONSE ELECTRIC INC.General Wiring
03/30/2021CompleteTOP SHELF ELECTRIC CORP—
02/26/2021Permit IssuedCAPUTEK ELEC'L SERVICES,—
02/04/2021CompleteWTG ELECTRIC INC.General Wiring
02/02/2021CompleteRESPONSE ELECTRIC INC.General Wiring
06/09/2020CompleteENTERPRISE ELEC'L SYSTEMSGeneral Wiring
10/23/2019CompleteTESTA ELECTRIC CO., INCGeneral Wiring
1 project · most recent 05/08/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
05/08/2026Permit IssuedAARCO CONTRACTING LLCScaffold, Sidewalk Shed
▾Field Inspections (DOB CAP) — 21
DateTypeResultReport
08/31/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/31/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/20/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/01/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/29/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/29/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/17/2024Pass-Final CND-Occupancy InspectionPassView ↗
07/18/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/16/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/13/2024Pass-Final CND-Occupancy InspectionPassView ↗
06/11/2024Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
05/04/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/11/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/26/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/14/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/13/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/10/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/13/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/13/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
04/15/2026Energy Code Compliance InspectionsDavid Katzprogress
04/15/2026Insulation placement and R valuesDavid Katzenergy_progress
04/15/2026Fire-Resistance Rated ConstructionDavid Katzprogress
04/15/2026Fire-Resistant Penetrations and JointsDavid Katzspecial
04/15/2026MasonryDavid Katzspecial
04/14/2026Tenant Protection Plan ComplianceDavid Katzspecial
05/31/2024FinalDavid Katzprogress
04/01/2024Fire-Resistance Rated ConstructionHugh Robothamprogress
04/01/2024Fire-Resistant Penetrations and JointsHugh Robothamspecial
01/31/2024Tenant Protection Plan ComplianceSANTIAGO HELMANspecial
06/12/2023Sprinkler SystemsYoung Suhspecial
02/22/2022Fire-Resistant Penetrations and JointsYoung Suhspecial
11/11/2021FinalYoung Suhprogress
11/11/2021Fire-Resistance Rated ConstructionYoung Suhprogress
07/28/2021Mechanical SystemsCharles Michelspecial
07/28/2021FinalCharles Michelprogress
07/23/2021FinalCharles Michelprogress
07/23/2021Mechanical SystemsCharles Michelspecial
07/01/2021Sprinkler SystemsCharles Michelspecial
06/08/2021Sprinkler SystemsCharles Michelspecial
03/29/2021FinalMD TOHFAZ UDDINprogress
03/29/2021FinalMD TOHFAZ UDDINprogress
02/05/2021Fire-Resistant Penetrations and JointsEugene Khananovspecial
02/05/2021HVAC insulation and sealing Eugene Khananovenergy_progress
01/29/2021HVAC insulation and sealing Eugene Khananovenergy_progress
Latest 25 of 36.
▾Documents — 509 on file (BIS + DOB NOW)
▸Plans & Drawings29
▸DOB NOWPlans/Sketch18
09/03/2026M00494624-I1Request digital key ↗
09/03/2026M00494627-I1Request digital key ↗
09/03/2026M00504156-I1Request digital key ↗
Showing 3 of 18 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler4
09/05/2026M00267008-I1Request digital key ↗
09/03/2026M00340890-P1Request digital key ↗
08/15/2026M00340890-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Plumbing4
09/05/2026M00262373-I1Request digital key ↗
09/05/2026M00337455-I1Request digital key ↗
09/04/2026M00370554-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems3
09/05/2026M00266614-I1Request digital key ↗
09/03/2026M00337536-I1Request digital key ↗
08/15/2026M00337536-P1Request digital key ↗
▸Applications & Permits89
▸BISPLAN / WORK APPROVAL APPLICATION38
05/13/2024123510254Open ↗
02/07/2023140939947Open ↗
10/01/2020140939947Open ↗
Showing 3 of 38 on file for this type
▸BISWORK PERMIT APPLICATION36
01/07/2022140939947Open ↗
07/31/2020123833806Open ↗
06/29/2020123833806Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWLPC Approval/Permit15
09/05/2026M00262373-I1Open ↗
09/03/2026M00337536-I1Open ↗
09/02/2026M00627505-I1Open ↗
Showing 3 of 15 on file for this type
▸Seals & Professional Certifications128
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION54
06/29/2020123833806Open ↗
05/01/2020123833806Open ↗
02/10/2020123510254Open ↗
Showing 3 of 54 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature29
09/05/2026M00262373-I1Open ↗
09/03/2026M00340890-P1Open ↗
09/03/2026M00340890-I1Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWProgress Inspector Seal & Signature17
09/01/2026M00337536-I1Open ↗
08/30/2026M00337536-P1Open ↗
08/29/2026M00494627-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/05/2026M00340890-I1Open ↗
09/02/2026M00267008-P1Open ↗
09/01/2026M00337536-I1Open ↗
Showing 3 of 16 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
05/01/2020123833806Open ↗
Showing 1 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
05/01/2020123833806Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/01/2020140939947Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/01/2020140939947Open ↗
▸Trade Schedules & Equipment35
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE14
12/19/2019123510254Open ↗
12/03/2019123510254Open ↗
03/19/2019123510254Open ↗
Showing 3 of 14 on file for this type
▸BISSELF-CERT PLUMBING NOTICE6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT6
08/02/2019123379806Open ↗
06/20/2017122265388Open ↗
06/20/2017122265388Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISEQUIPMENT USE PERMITS3
08/02/2019123379806Open ↗
06/06/2017122265388Open ↗
06/06/2017122265388Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
05/09/2024123510254Open ↗
▸DOB NOWFDNY: Letter of No Objection1
08/13/2026M00687934-I1Open ↗
▸Safety & Tenant Protection18
▸BISTenant Protection Plan and Notes10
10/01/2020140939947Open ↗
05/01/2020123833806Open ↗
11/07/2019123741102Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWTenant Protection Plan6
09/03/2026M00340890-P1Open ↗
09/03/2026M00337536-I1Open ↗
08/15/2026M00340890-I1Open ↗
Showing 3 of 6 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM2
12/12/2019123741102Open ↗
12/18/2018123510254Open ↗
▸Environmental & Asbestos36
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
09/05/2026M00262373-I1Open ↗
09/03/2026M00340890-P1Open ↗
09/03/2026M00337536-I1Open ↗
Showing 3 of 17 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)12
10/01/2020140939947Open ↗
05/01/2020123833806Open ↗
11/07/2019123741102Open ↗
Showing 3 of 12 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
06/25/2018123379806Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/31/2026M00687934-I1Open ↗
▸Energy Compliance24
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS9
11/07/2019123741102Open ↗
08/06/2019123379806Open ↗
05/30/2019123510254Open ↗
Showing 3 of 9 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS4
03/01/2023140939947Open ↗
08/06/2019123379806Open ↗
06/14/2017122493532Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
03/01/2023140939947Open ↗
03/30/2021123741102Open ↗
10/01/2020140939947Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
05/08/2024123510254Open ↗
03/30/2021123741102Open ↗
▸BISTECHNICAL REPORT: ENERGY2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/01/2020140939947Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
05/09/2024123510254Open ↗
▸BISTR8: Energy Code Progress Inspections1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWEN2: As Built Energy Analysis1
09/02/2026M00751514-I1Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY5
03/02/2023140939947Open ↗
03/01/2023140939947Open ↗
07/14/2021123833806Open ↗
Showing 3 of 5 on file for this type
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
07/07/2020123833806Open ↗
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
01/03/2017122493532Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
07/07/2020123833806Open ↗
▸Approvals, Objections & Sign-offs54
▸BISLANDMARKS APPROVAL24
10/27/2020140939947Open ↗
05/01/2020123833806Open ↗
05/01/2020123833806Open ↗
Showing 3 of 24 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST14
05/17/2024123510254Open ↗
03/02/2023140939947Open ↗
07/14/2021123833806Open ↗
Showing 3 of 14 on file for this type
▸BISADMINISTRATIVE OBJECTIONS6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
01/03/2017122493532Open ↗
Showing 1 of 4 on file for this type
▸BISLANDMARKS SIGNOFF4
05/14/2024123510254Open ↗
03/02/2023140939947Open ↗
03/30/2021123741102Open ↗
Showing 3 of 4 on file for this type
▸BISFINAL2
05/08/2024123510254Open ↗
07/07/2020123833806Open ↗
▸Cost, Insurance & Ownership32
▸BISCOST AFFIDAVIT28
03/01/2023140939947Open ↗
07/14/2021123833806Open ↗
10/01/2020140939947Open ↗
Showing 3 of 28 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
05/08/2024123510254Open ↗
03/30/2021123741102Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
08/07/2018123379806Open ↗
▸BISWELDERS AFFIDAVIT1
05/02/2018122916416Open ↗
▸Filing & Intake Forms47
▸BISEFILING COVER SHEET19
05/01/2020123833806Open ↗
11/07/2019123741102Open ↗
12/18/2018123510254Open ↗
Showing 3 of 19 on file for this type
▸BISADDITIONAL INFORMATION15
02/15/2023140939947Open ↗
12/09/2019123741102Open ↗
03/19/2019123510254Open ↗
Showing 3 of 15 on file for this type
▸BISBOROUGH INTAKE FORM12
07/31/2020123833806Open ↗
07/10/2020123833806Open ↗
06/29/2020123833806Open ↗
Showing 3 of 12 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
10/01/2020140939947Open ↗
▸Other Documents9
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION3
07/24/2017122265388Open ↗
04/03/2017122916416Open ↗
Showing 2 of 3 on file for this type
▸DOB NOWProof of Historic Building3
09/02/2026M00627505-I1Open ↗
09/02/2026M00627497-I1Open ↗
08/13/2026M00687934-I1Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form2
08/07/2018123379806Open ↗
Showing 1 of 2 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026M01059635-I1Open ↗