HPD05/01/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD06/25/2025§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS AT, GUARDRAILS OVER OPENING BELOW GRADE AT, SOUTHEAST SECTION, EAST YARD
HPD06/25/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED MARBLE DOOR SADDLE AT DOOR TO SOUTH WALL BUILDING 'S VESTIBULE , AT PUBLIC HALL, 1st STORY
HPD06/25/2025§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS AT STAIR BALUSTRADE AND GUARDRAILS OVER OPEINING BELOW GRADE AT, NORTHWEST SECTION, NORTH YARD
ECB02/13/2023OBSERVED, - MULTIPLE DWELLING BUILDING, TERRACOTTA FACADE, EXPOSURE # 1&4, SEVERAL CRACKS, MISSING MORTAR, CRACKS AROUND WINDOW ANCHORS. ALSO, ROOF LEVEL DETERIORATED CORNICE WITH SEVERAL HOLES., MAINTAIN EXTER$6K due
ECB02/13/2023OBSERVED, -AT EXPOSURE # 4, CRACKED RETAINING WALLS. ALSO, EXIT WAY, DETERIORATED METAL STAIR (HOLES, BROKEN SUPPORT ), MAINTAIN EXTERIOR BUILDING WALL$6K due
ECB03/24/2022EXIT DOOR NOT SELFCLOSING OBSERVED:FIREPROOF SELFCLOSING DOOR@CELLAR LEVEL EXP2&4,EXIT DOOR DONT SELFCLOSING PROPERLY DUE KNOCKING OF DOORFRAME OR THERES NO CLOSING SYSTEM INSTALLED.REPAIR/REPLACE DOOR$3K due
ECB03/24/2022FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:NO FIRESTOPPING PER BC712.3;27-345.OBSERVED:@CELLAR LEVEL,ELECTRICAL RM,BOILER RM&GAS METERRM,SEVERAL HOLES ON CEILING&WALLS DUE TO PIPES&CABLES PENETRATION W/O$6K due
DOB08/16/1993V-DOB VIOLATION - ACTIVE
ECB01/25/2018FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED AT WATER MAIN LOCATED IN THE CELLAR. MAIN GROUNDING CONDUCTOR FOR BLDGS ELECTRICAL SYSTEMS DISCONNECTED FROM WATER MAIN PIPE;FLOATING GROUND. PLEASE KNOW THAT FAILNothing owed — awaiting certificate of correction
ECB12/22/2017FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35234713J ISSUED ON 03/02/17 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. WORK W/O PERMIT; NOTE AT CELLAR LEVEL INSTALLED BOILERS 2 W/NONothing owed — awaiting certificate of correction
ECB11/03/2017FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35234713J ISSUED 03/02/17 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. WORK WITHOUT A PERMIT. NONothing owed — awaiting certificate of correction
ECB09/12/2017FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35234713J ISSUED ON 03/02/17 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28201.1 AND 1RCNY 102-01. AT CELLAR,BOILNothing owed — awaiting certificate of correction
ECB07/26/2017FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35234713J ISSUED ON 3-2-17 & TO FILE A C OF C PURSUANT TO 28-201.1 & RCNY 102.01. NO COMPLIANCE RECORDED FOR WORK W/O A PERMIT. REMEDY: COMPLY W/COMNothing owed — awaiting certificate of correction
ECB05/31/2017FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35234713J ISSUED ON 3-02-17 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. FOR WORK W/O A PERMIT. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE ANothing owed — awaiting certificate of correction
ECB03/02/2017FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION I OBSERVED IN THE CELLAR IN THE GAS METER ROOM NO VENTILATION WHICH IS CONTRARY TO THE REQUIREMENTS OF FGC AS PER APPENDIX E SECTION ENothing owed — awaiting certificate of correction
ECB03/02/2017WORK WITHOUT A PERMIT.AT THE TIME OF INSPECTION I OBSERVED I THE BOILER ROOM IN THE CELLAR I OBSERVED TWO HOT WATER HEATERS THAT WERE MANUFATURED ON 4/27/16 AND 4/25/08.DOB RECORDS FOR THIS BUILDING FROM 11/25Nothing owed — awaiting certificate of correction
ECB08/05/2014OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BLDG DEPT RECORDS. NOTED: BUILDING IS CURRENTLY OCCUPIED AS A 17 FAMILY DWELLING CONTRARY TO COFO #230719 WHICH CLEARLY STATES TOTAL 8 FAMILNothing owed — awaiting certificate of correction