← Back
Five to six families
153 AVENUE B
MANHATTAN · BIN 1004764
💬 Discuss this project
1900Year Built
4Stories
C2Building Class
R7AZoning
6,440 sfGross Floor Area
5Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Five to six families · Owner of record: 153 B LLC · 1,633 sf lot · 3.94 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralPlumbing
Roof1p · 1 filing · 3 docs
Floor 413p · 1 filing · 10 docs
Floor 37p · 1 filing · 10 docs
Floor 2
Floor 1
Cellar2p · 2 filings · 14 docs
Basement9p · 2 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AMERICAS GENERAL CONTRACTING & ROOF807/08/2026
J G CONSTRUCTION SRVCS607/08/2026
153 B LLC203/22/2026
153 AVENUE B INC C O REM203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/19/2017$6.6M—153 AVENUE B, INC. → 153 B LLC$1,029/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DAVID KEANE P.E., P.C.406/23/2025
SELLDORF ARCHITECTS202/13/2024
MOHAMMAD AHEAD, PE106/05/2023
LORING CONSULTING ENGINEERS, INC.103/09/2022
BAILEYS ENGINEERING PC207/19/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CODE1403/21/2026
ARSENAL BUILDING CONSULTANTS LLC203/21/2026
AE DESIGN SOLUTION403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HARD SAFARI CORPGeneral Contractor807/08/2026
J & G CONSTRUCTION SVCSGeneral Contractor407/08/2026
EVEREST SCAFFOLDING INCGeneral Contractor307/08/2026
EXCELLENT GENERAL CONTRA*General Contractor207/08/2026
A.M.N. CORPORATIONPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVID KEANE PE, P.C.2835406/23/2025
IVAN DESIGN ENGINEERING &6983111/17/2021
Building Lifecycle
All (54)Filed (10)Permit Issued (12)Signed Off (9)Violation (7)Inspection (2)Objection (4)Special Inspection (10)
04/01/2026
Signed off — Alteration
Interior renovation and combination of dwelling units on the 003 and 004 floors. Construction of an interior access stair. No change in use, occupancy or egress.
M00992512-S1
07/31/2025
Signed off — Alteration
NEW COMMUNICATION (NON-EGRESS) STAIR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00618295-I1
06/25/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/23/2025
Filed — Alteration
Interior renovation and combination of dwelling units on the 003 and 004 floors. Construction of an interior access stair. No change in use, occupancy or egress.
M00992512-P1
04/16/2025
Signed off — Alteration
REINFORCING AND REPAIR OF AN EXISTING BROWNSTONE FRONT FACADE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M00907249-I1
02/06/2025
Signed off — Alteration
Interior renovation and combination of dwelling units on the 003 and 004 floors. Construction of an interior access stair. No change in use, occupancy or egress.
M00992512-I1
02/06/2025
Signed off — Alteration
M00584140-I1
01/24/2025
Permit issued — Structural
M00618295-I1-ST
05/22/2024
Permit issued — Structural
M00992512-S1-ST
05/22/2024
Permit issued — General Construction
M00992512-I1-GC
05/13/2024
Signed off — Alteration
INSTALLATION OF HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLDING. NO CHANGE IN USE, OCCUPANCY OR EGRESS. WORK SHALL COMPLY WITH CHAPTER 33 OF NYCC.
M00882012-I1
04/10/2024
Filed — Alteration
Interior renovation and combination of dwelling units on the 003 and 004 floors. Construction of an interior access stair. No change in use, occupancy or egress.
M00992512-S1
02/13/2024
Filed — Alteration
Interior renovation and combination of dwelling units on the 003 and 004 floors. Construction of an interior access stair. No change in use, occupancy or egress.
M00992512-I1
01/22/2024
Permit issued — Structural
M00907249-I1-ST
01/18/2024
Special inspection requirement — Final
Annabelle Selldorf
08/22/2023
Permit issued — Structural
M00907249-I1-ST
08/09/2023
Objection resolved — Addressed
08/03/2023
Objection resolved — Addressed
07/31/2023
Objection raised — Scope
07/31/2023
Objection raised — Admin
07/27/2023
Filed — Alteration
REINFORCING AND REPAIR OF AN EXISTING BROWNSTONE FRONT FACADE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M00907249-I1
06/13/2023
Signed off — Alteration
New plumbing fixtures for basement apartment. No change in use, egress, occupancy.
M00649492-I1
06/05/2023
Filed — Alteration
INSTALLATION OF HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLDING. NO CHANGE IN USE, OCCUPANCY OR EGRESS. WORK SHALL COMPLY WITH CHAPTER 33 OF NYCC.
M00882012-I1
06/05/2023
Permit issued — Supported Scaffold
M00882012-I1-SH
06/05/2023
Permit issued — Supported Scaffold
M00882012-I1-SF
01/17/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/23/2022
Permit issued — Plumbing
M00649492-I1-PL
06/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/22/2022
Permit issued — Plumbing
M00649492-I1-PL
03/09/2022
Filed — Alteration
New plumbing fixtures for basement apartment. No change in use, egress, occupancy.
M00649492-I1
11/17/2021
Filed — Alteration
NEW COMMUNICATION (NON-EGRESS) STAIR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00618295-I1
10/25/2021
Permit issued — General Construction
M00584140-I1-GC
10/25/2021
Special inspection requirement — Structural Steel - Details
DAVID KEANE
10/25/2021
Special inspection requirement — Masonry
DAVID KEANE
10/25/2021
Special inspection requirement — Post-installed Anchors
DAVID KEANE
10/25/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
DAVID KEANE
10/25/2021
Special inspection requirement — Structural Steel - High Strength Bolting
DAVID KEANE
10/25/2021
Special inspection requirement — Structural Steel - Welding
Ivan Luk
10/25/2021
Special inspection requirement — Final
DAVID KEANE
10/25/2021
Special inspection requirement — Structural Wood Frame
DAVID KEANE
09/16/2021
Filed — Alteration
M00584140-I1
10/24/2019
Signed off — Alteration
M00195036-I1
10/24/2019
Signed off — Alteration
M00195044-I1
07/23/2019
Permit issued — Supported Scaffold
M00195044-I1-SF
07/19/2019
Filed — Alteration
M00195036-I1
07/19/2019
Filed — Alteration
M00195044-I1
07/19/2019
Permit issued — Sidewalk Shed
M00195036-I1-SH
07/17/2019
Special inspection requirement — Final
PAUL BAILEY
07/19/2018
Violation issued (ECB, closed)
Cranes and Derricks
03/27/2014
Violation issued (HPD, closed)
A
03/27/2014
Violation issued (HPD, closed)
B
03/08/2014
Violation issued (HPD, closed)
B
03/08/2014
Violation issued (HPD, closed)
B
07/20/2010
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offHARD SAFARI CORP01/24/2025
DOB NOWStructuralPermit IssuedHARD SAFARI CORP05/22/2024
DOB NOWGeneral ConstructionSigned-offHARD SAFARI CORP05/22/2024
DOB NOWStructuralSigned-offEXCELLENT GENERAL CONTRA*01/22/2024
DOB NOWStructuralSigned-offEXCELLENT GENERAL CONTRA*08/22/2023
DOB NOWSupported ScaffoldSigned-offJ & G CONSTRUCTION SVCS06/05/2023
DOB NOWSupported ScaffoldSigned-offJ & G CONSTRUCTION SVCS06/05/2023
DOB NOWPlumbingSigned-offA.M.N. CORPORATION07/23/2022
DOB NOWPlumbingSigned-offA.M.N. CORPORATION06/22/2022
DOB NOWGeneral ConstructionSigned-offHARD SAFARI CORP10/25/2021
DOB NOWSupported ScaffoldSigned-offEVEREST SCAFFOLDING INC07/23/2019
DOB NOWSidewalk ShedSigned-offEVEREST SCAFFOLDING INC07/19/2019
BISPLISSUEDA.M.N. CORPORATION06/08/2020
BISOTISSUEDHARD SAFARI CORP07/01/2019
BISPLISSUEDA.M.N. CORPORATION06/07/2019
BISOTISSUEDCUB CRAFT LLC05/21/2018
BISMHISSUEDHVAC SERVICES LLC03/09/2018
BISOTISSUEDCUB CRAFT LLC02/27/2018
BISPLISSUEDA.M.N. CORPORATION01/11/2018
BISPLISSUEDA.M.N. CORPORATION12/05/2017
BISOTISSUEDCUB CRAFT LLC11/03/2017
BISPLISSUEDDNA PLUMBING CONTR. INC04/20/2016
BISPLISSUEDDNA PLUMBING CONTR. INC10/28/2014
BISOTISSUEDGHCR, LLC10/21/2014
BISPLISSUEDSPARTAN PLBG & HTG INC01/31/2013
BISOTISSUEDNOEL G MUIR01/23/2013
BISOTISSUEDDL RESTORATION COMPANY02/16/2011
BISOTISSUEDNOEL G MUIR05/04/2010
4 projects · most recent 05/30/2023
General Wiring
FiledStatusContractorScope
05/30/2023Permit IssuedRICHARD NEU—
09/21/2022Permit IssuedAVALON ELECTRIC CORP.General Wiring
04/05/2022CompleteAVALON ELECTRIC CORP.General Wiring
07/18/2019CompleteBOROWIDE ELECT'L CONTR'S—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
01/17/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/27/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
01/18/2024FinalAnnabelle Selldorfprogress
10/25/2021Structural Steel - DetailsDAVID KEANEspecial
10/25/2021MasonryDAVID KEANEspecial
10/25/2021Post-installed AnchorsDAVID KEANEspecial
10/25/2021Structural Stability – Alterations of existing buildingsDAVID KEANEspecial
10/25/2021Structural Steel - High Strength BoltingDAVID KEANEspecial
10/25/2021Structural Steel - WeldingIvan Lukspecial
10/25/2021FinalDAVID KEANEprogress
10/25/2021Structural Wood FrameDAVID KEANEprogress
07/17/2019FinalPAUL BAILEYprogress
▾Documents — 171 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch8
09/03/2026M00584140-I1Request digital key ↗
09/03/2026M00618295-I1Request digital key ↗
09/02/2026M00649492-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/05/2026M00195036-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/05/2026M00195044-I1Request digital key ↗
▸Applications & Permits30
▸BISPLAN / WORK APPROVAL APPLICATION17
03/27/2020123145097Open ↗
03/18/2020123145097Open ↗
03/18/2020123145097Open ↗
Showing 3 of 17 on file for this type
▸BISWORK PERMIT APPLICATION13
06/08/2020123145097Open ↗
07/02/2019123363733Open ↗
05/24/2018123145097Open ↗
Showing 3 of 13 on file for this type
▸Zoning, Tax Lot & Property Records1
▸BISFLOOD ZONE DESIGN CERTIFICATION1
12/29/2017140728176Open ↗
▸Seals & Professional Certifications37
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/05/2026M00195044-I1Open ↗
08/27/2026M00992512-P1Open ↗
08/27/2026M00992512-S1Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
02/22/2018123363733Open ↗
02/22/2018123363733Open ↗
02/22/2018123363733Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/27/2026M00618295-I1Open ↗
08/27/2026M00618295-I1Open ↗
08/27/2026M00618295-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/29/2026M00195036-I1Open ↗
08/27/2026M00618295-I1Open ↗
08/27/2026M00618295-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
02/22/2018123363733Open ↗
12/29/2017140728176Open ↗
10/27/2017123145097Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
02/22/2018123363733Open ↗
10/27/2017123145097Open ↗
12/10/2012121428874Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/29/2017140728176Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
12/10/2012121428874Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/29/2017140728176Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/07/2014140261008Open ↗
▸Trade Schedules & Equipment15
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE12
03/27/2020123145097Open ↗
03/18/2020123145097Open ↗
03/18/2020123145097Open ↗
Showing 3 of 12 on file for this type
▸BISSCHEDULE B - PLUMBING3
12/29/2017140728176Open ↗
10/07/2014140261008Open ↗
12/10/2012121428874Open ↗
▸Safety & Tenant Protection1
▸DOB NOWTenant Protection Plan1
08/13/2026M00195036-I1Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/27/2026M00992512-P1Open ↗
08/27/2026M00992512-S1Open ↗
08/27/2026M00992512-I1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)5
02/22/2018123363733Open ↗
12/29/2017140728176Open ↗
10/27/2017123145097Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/19/2010120295607Open ↗
▸Energy Compliance12
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
02/24/2021123145097Open ↗
02/24/2021123145097Open ↗
12/29/2017140728176Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
02/22/2018123363733Open ↗
10/30/2017123145097Open ↗
10/27/2017123145097Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
03/23/2021123363733Open ↗
02/24/2021123145097Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/29/2017140728176Open ↗
▸BISNYCECC ANALYSIS1
12/29/2017140728176Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00584140-I1Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: RESPONSIBILITY9
03/23/2021123363733Open ↗
03/23/2021123363733Open ↗
03/23/2021123363733Open ↗
Showing 3 of 9 on file for this type
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
03/23/2021123363733Open ↗
02/24/2021123145097Open ↗
06/14/2013121428874Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
07/02/2019123363733Open ↗
06/14/2013121428874Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
12/10/2012121428874Open ↗
03/19/2010120295607Open ↗
▸Cost, Insurance & Ownership13
▸BISCOST AFFIDAVIT10
03/23/2021123363733Open ↗
02/24/2021123145097Open ↗
02/22/2018123363733Open ↗
Showing 3 of 10 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT3
02/28/2018123363733Open ↗
11/06/2017123145097Open ↗
10/22/2014140261008Open ↗
▸Filing & Intake Forms22
▸BISADDITIONAL INFORMATION10
03/27/2020123145097Open ↗
12/18/2019123363733Open ↗
11/18/2019140728176Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM6
03/27/2020123145097Open ↗
03/17/2020123145097Open ↗
11/14/2019140728176Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET4
02/22/2018123363733Open ↗
10/27/2017123145097Open ↗
12/10/2012121428874Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
12/29/2017140728176Open ↗
10/07/2014140261008Open ↗
▸Other Documents1
▸BISSUBSTANTIAL IMPROVEMENT CALCULATIONS1
12/29/2017140728176Open ↗