DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB12/28/2016V-DOB VIOLATION - ACTIVE
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB10/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
DOB04/22/2014V-DOB VIOLATION - ACTIVE
DOB04/22/2014V-DOB VIOLATION - ACTIVE
DOB04/22/2014V-DOB VIOLATION - ACTIVE
DOB04/22/2014OCCUPANCY CONTRARY TO C/O #204015
DOB04/22/2014V-DOB VIOLATION - ACTIVE
DOB04/22/2014OCCUPANCY CONTRARY BASEMENT
DOB04/22/2014FAILURE TO MAINTAIN MISSING SMOKE/CARBONMONOXIDE DETECTORS
DOB04/22/2014FAILURE TO MAINTAIN NO FIRE STOPPING
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB10/08/2010V-DOB VIOLATION - ACTIVE
HPD09/22/1999§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING INSTALLED THRUOUT CELLAR.
DOB05/04/1998V-DOB VIOLATION - ACTIVE
DOB09/16/1997V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB06/07/1994V-DOB VIOLATION - ACTIVE
DOB06/07/1994V-DOB VIOLATION - ACTIVE
DOB05/31/1994V-DOB VIOLATION - ACTIVE
DOB06/28/1993V-DOB VIOLATION - ACTIVE
DOB06/28/1993V-DOB VIOLATION - ACTIVE
HPD12/18/1990§ 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT EAST WALL AND WEST WALL 2 STY ROOM 216 DALMAN 262 1650 ER1.
HPD12/18/1990§ 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT EAST WALL 5 SQUARE FEET 2 STY ROMM 215 LOUISE DALMAN 262 1650 ER1.
HPD06/19/1990§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CELOTEX SUSPENDED CLG BASEMENT STY NORTHWEST APT 102. LOCATED AT APT 102
HPD06/19/1990§ 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AT EAST KITCHENETTE ON 1 STY APT M42 ER1. , SECTION '' ''
HPD06/19/1990§ 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING SOUTHWEST OF REAR ROOM AT 3 STY APT 352. LOCATED AT APT 352
HPD06/19/1990§ 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT EAST WALL AT BATHROOM ROOM ON 1 STY APT M41 ER1. LOCATED AT APT M41
DOB10/12/19891
ECB06/16/2025CLASS 2 ITEM: PROVIDE BOTTOM SWING DOOR TO SELF CLOSE.Nothing owed — awaiting certificate of correction
ECB11/15/2022DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). IN CAR PHONE NOT WORKING. BRAKE MAINTENANCE TAG EXPIRED ON 7/14/21. TOP OF CAR EXHAUST FAN MISSING.Nothing owed — awaiting certificate of correction
ECB11/15/2022FOUND AO SMITH BOILER MODEL # HW-670 300 SERIAL # 2035120687564 UNREGISTERED., MAINTAIN BOILER; REGISTER THE BOILER AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB11/09/2022FOUND HB SMITH BOILER MODEL #28HE-10, SERIAL #28HE-10-142395 UNREGISTERED. REGISTER THE BOILER AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB11/12/2021CLEAN BASE OF CHIMNEY REMOVE STORAGE IN BOILER ROOM CLEAN BASE OF CHIMNEY UNREGISTERED BOILER CORRECT VIOLATION & SEND CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB02/19/2020UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT IN USE. I OBSERVED IN THE BASEMENT,IN ROOM 103/GAS ROOM TEMPORARY ROMEX CABLE IN USE AND ARMORED BY CABLE ARE NOT SUPPORTED PROPERLY. ALSO NOTE EXPOSED CONDUCTONothing owed — awaiting certificate of correction
ECB09/12/2019(97X17/11L10)(97X17)UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE.RESTORED TO SERVICE IMMEDIATELY AND CONTACT NYCDOB FOR A COMPLETE INSPECTION(11L10)REPAIR TOP RUN STATION.Nothing owed — awaiting certificate of correction
ECB05/02/2019B 154 FOUND HB SMITH OIL FIRED BOILER, WITH RECURRING CONDITION VIOLATION # 32098180N NOT REGISTERED, REGISTER THE BOILER AND SUBMIT A CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB08/15/2018HB SMITH 28HE-10 BOILER: 50A MISSING GUARDS ON GAUGE GLASS 50B-BODY DRAIN PLUGGED ON RELIEF VALVE; 50C-FUMERS AT BURNER START UP; 50D-PRESSURE CONTROL MANIFOLD WRONG SIZE SEE PREVIOUS VIOLATION #32083365F.Nothing owed — awaiting certificate of correction
ECB03/21/201836,15,50A,50B. B254-36 FOUND HB SMITH BOILER NOT REGISTERED. 50A-NO STORAGE IN BOILER ROOM; B-BURNER HAS FUMES ON START; REGISTER THE BOILER CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECNothing owed — awaiting certificate of correction
ECB07/13/2017FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN LAUNDRY ROOM: RECEPTACLES THAT PROVIDE ELECTRICAL POWER TO WASHER MACHINES ARE NOT GFCI PROTECTED. REM. COMPLY WITHNothing owed — awaiting certificate of correction
ECB07/13/2017FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED IN BASEMENT OF ANNEX BUILDING: MAIN GROUNDING CONDUCTOR CLAMP FOR BUILDINGS ELECTRICAL SYSTEMS TOO BIG IN DIAMETER FOR WATER MAIN PIPE. AS A RESULT, ADEQUATE GROUNNothing owed — awaiting certificate of correction
ECB10/28/1988FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS FROM EVERY FLOOR . REMEDY: EGRESS DOOR.Nothing owed — awaiting certificate of correction
Miscellaneous asylum / home · Owner of record: NYC DEPARTMENT OF HOMELESS SERVICES · 43,000 sf lot · 1.87 FAR built · Flood zone X