← Back
Contractors warehouse
315 CASANOVA STREET
BRONX · Hunts Point · BIN 2006937
💬 Discuss this project
1956Year Built
1Stories
E2Building Class
M3-1Zoning
13,240 sfGross Floor Area
1Units
0 Open Violations
Contractors warehouse · 20,000 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ACTION CARTING703/22/2026
CASANOVA ST REALTY103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EK ENGINEERING,P.C.112/22/2023
CNY ENGINEERING P.C310/26/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MCMANUS MECH MAINT P H IN403/21/2026
S M EXPEDITING203/21/2026
CNY ENGINEERING PC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TAINO MECHANICAL CONTRACTGeneral Contractor303/21/2026
SANTOIEMMA, JOSEPHElectrical103/21/2026
MCMANUS MECH MAINT P&H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EK ENGINEERING, P.C.6883112/22/2023
CNY ENGINEERING P.C3304310/26/2023
Building Lifecycle
All (21)Filed (4)Permit Issued (2)Signed Off (1)Violation (1)Inspection (3)Objection (8)Special Inspection (2)
02/29/2024
Signed off — Alteration
X00961633-I1
01/04/2024
Permit issued — Mechanical Systems
X00961633-I1-MS
12/22/2023
Filed — Alteration
X00961633-I1
11/08/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/26/2023
Filed — Alteration
INSTALL NEW GAS HEATERS FOR THE EXISTING 1-STORY WAREHOUSE BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00807147-P2
10/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YUE ZHOU
10/16/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/27/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/11/2023
Filed — Alteration
INSTALL NEW GAS HEATERS FOR THE EXISTING 1-STORY WAREHOUSE BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00807147-P1
05/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YUE ZHOU
03/20/2023
Permit issued — Plumbing
X00807147-I1-PL
01/26/2023
Objection raised — Other
01/26/2023
Objection resolved — Addressed
01/26/2023
Objection raised — Other
01/26/2023
Objection resolved — Addressed
01/26/2023
Objection raised — Other
01/26/2023
Objection resolved — Addressed
01/17/2023
Objection raised — Scope
01/17/2023
Objection resolved — Addressed
01/09/2023
Filed — Alteration
INSTALL NEW GAS HEATERS FOR THE EXISTING 1-STORY WAREHOUSE BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00807147-I1
05/06/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offTAINO MECHANICAL CONTRACT01/04/2024
DOB NOWPlumbingSigned-offMCMANUS MECH MAINT P&H IN03/20/2023
BISPLISSUEDBLATT PLUMBING INC12/22/2008
BISMHISSUEDPHILIP NABLE12/17/2008
1 project · most recent 10/26/2023
Gas
FiledStatusContractorScope
10/26/2023Signed-offMCMANUS MECH MAINT P&H INGas
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/08/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/16/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/27/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
10/24/2023Fire-Resistant Penetrations and JointsYUE ZHOUspecial
05/04/2023Fire-Resistant Penetrations and JointsYUE ZHOUspecial
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/22/2026X00807147-I1Request digital key ↗
08/22/2026X00807147-P2Request digital key ↗
08/22/2026X00807147-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
12/23/2008210082961Open ↗
12/17/2008210082961Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
12/12/2008210082961Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/22/2026X00807147-I1Open ↗
08/22/2026X00807147-P2Open ↗
08/22/2026X00807147-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
02/02/2009210082961Open ↗
12/12/2008210082961Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026X00807147-P1Open ↗
08/28/2026X00807147-P2Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/12/2008210082961Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
12/12/2008210082961Open ↗
▸Trade Schedules & Equipment3
▸BISEQUIPMENT USE APPLICATION/PERMIT1
02/23/2009210082961Open ↗
▸BISSCHEDULE B - PLUMBING1
12/12/2008210082961Open ↗
▸BISEQUIPMENT USE PERMITS1
02/23/2009210082961Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/22/2026X00807147-P1Open ↗
08/22/2026X00807147-I1Open ↗
08/22/2026X00807147-P2Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
12/12/2008210082961Open ↗
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026X00961633-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
02/23/2009210082961Open ↗
02/02/2009210082961Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
12/12/2008210082961Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/02/2009210082961Open ↗
12/12/2008210082961Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
12/12/2008210082961Open ↗