← Back
Shopping center, with or without parking
3861 NOSTRAND AVENUE
BROOKLYN · BIN 3204766
💬 Discuss this project
1960Year Built
1Stories
K6Building Class
R3-2Zoning
81,018 sfGross Floor Area
15Units
LL97 Covered14 Open Violations 13 unresolved · 1 paperwork only ▸FDNY Report ↗
Shopping center, with or without parking · Owner of record: NOSTRAND PROPERTY OWNER LLC · 133,000 sf lot · 0.61 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 1Under Construction46p · 5 filings · 20 docs
CellarUnder Construction37p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HGC PARTNERS807/08/2026
ASHKENAZY ACQUISITION1604/09/2026
AAC REALTY303/22/2026
NOSTRAND PROPERTY OWNER1803/22/2026
NOSTRAND PROPERTY LLC AAC103/22/2026
COUNTRY LEASING LIMITED1803/22/2026
LAURION RESTAURANT CORP303/22/2026
OWNER OF 3849 NOSTRAND AV103/22/2026
LAURION REST CORP103/22/2026
COUNTRY LEASING LIMITED PARTNERS903/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/21/2018$38.2M—COUNTRY LEASING LIMITED PARTNERSHIP → NOSTRAND PROPERTY OWNER LLC$472/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YANG ENGINEERING LLC704/30/2026
HBC ARCHITECTS301/12/2026
MOHAMMAD AHEAD, PE309/09/2025
MADRIAGA ENGINEERING P.C.607/01/2025
LINO PICINIC ARCHITECT111/30/2023
LEON SKVIRSKY PE209/21/2020
FANG ARCHITECT106/15/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILDING BROTHERS403/21/2026
J A EXPEDITING603/21/2026
SD DESIGN STUDIO1203/21/2026
INDESIGN STUDIO203/21/2026
JAM CONSULTANTS, INC.203/21/2026
LOUIS STRIAR603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STRUCTURECRAFT CONTRACTINGeneral Contractor303/21/2026
SIGNSTAR NYCScaffold307/08/2026
HIGH QUALITY CONSTRUCTIONGeneral Contractor203/21/2026
ACTIVE SIGNSScaffold207/08/2026
ACER CONSTRUCTION INCGeneral Contractor207/08/2026
NEPTUNE SIGNS AWNINGSScaffold107/08/2026
WESBUILT CONSTRUCTION MANGeneral Contractor104/09/2026
CUBE BUILDERS GROUP NYGeneral Contractor104/09/2026
JEM FIRE PREVENTION INCFire Protection106/28/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
PIPESTYLISTS, INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YANG ENGINEERING LLC8376401/23/2026
J&R DESIGN AND INSPECTION6637507/01/2025
Building Lifecycle
All (218)Filed (23)Permit Issued (15)Signed Off (9)Violation (60)Inspection (4)Objection (77)Special Inspection (30)
05/28/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/26/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/19/2026
Objection resolved — Addressed
05/19/2026
Objection resolved — Addressed
05/18/2026
Objection resolved — Addressed
05/18/2026
Objection resolved — Addressed
05/18/2026
Objection resolved — Addressed
05/18/2026
Objection resolved — Addressed
05/18/2026
Objection resolved — Addressed
05/18/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
05/01/2026
Objection raised — Other
04/30/2026
Filed — No Work
B01378377-I1
03/25/2026
Special inspection requirement — Public Assembly Emergency Lighting
Jian Yang
01/28/2026
Special inspection requirement — Energy Code Compliance Inspections
Jian Yang
01/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jian Yang
01/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jian Yang
01/28/2026
Special inspection requirement — Electrical motors and elevators
Jian Yang
01/28/2026
Special inspection requirement — Interior lighting power
Jian Yang
01/28/2026
Special inspection requirement — Lighting controls
Jian Yang
01/23/2026
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION FOR STORE H ONLY; NO EGRESS CHANGES, NO EXTERIOR WORK. SEEK NEW C.O. TO RECLASSIFY EXISTING STORE/OFFICE TO EATING & DRINKING ESTABLISHMENT WITH ACCESSORY AMUSEMENT DEVICES (1ST FL & CELLAR).
B01267546-P2
01/12/2026
Filed — No Work
B01339459-I1
01/12/2026
Violation issued (ECB, closed)
Construction
01/06/2026
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION FOR STORE H ONLY; NO EGRESS CHANGES, NO EXTERIOR WORK. SEEK NEW C.O. TO RECLASSIFY EXISTING STORE/OFFICE TO EATING & DRINKING ESTABLISHMENT WITH ACCESSORY AMUSEMENT DEVICES (1ST FL & CELLAR).
B01267546-P1
12/24/2025
Signed off — Alteration
NEW PARTIAL HEIGHT INTERIOR NON-LOAD BEARING STUD WALL, AND ENTRY CHECK-IN DOORS WITHIN AN EXISTING GYM. NO CHANGE IN OCCUPANCY, USE OR EGRESS
B01287497-I1
12/22/2025
Permit issued — General Construction
B01267546-I1-GC
12/09/2025
Filed — Alteration
NEW PARTIAL HEIGHT INTERIOR NON-LOAD BEARING STUD WALL, AND ENTRY CHECK-IN DOORS WITHIN AN EXISTING GYM. NO CHANGE IN OCCUPANCY, USE OR EGRESS
B01287497-P1
12/09/2025
Violation issued (FDNY_ORDER, closed)
12/09/2025
Violation issued (FDNY_ORDER, closed)
12/09/2025
Special inspection requirement — Final
Matthew Dresser
12/08/2025
Signed off — Alteration
B01265802-I1
12/08/2025
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - PUREGYM. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B01265801-I1
12/08/2025
Signed off — Alteration
REFACE ONLY OF NON-ILLUMINATED NON-ADVERTISING DOUBLE-FACE TENANT PANELS ON TENANT DIRECTORY FILED UNDER JOB# 321134134 ON STRUCTURE FILED UNDER JOB# 321134125 - IN PROPERTY LINES - PUREGYM. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B01265803-I1
12/05/2025
Objection resolved — Addressed
11/19/2025
Permit issued — Plumbing
B01267546-S1-PL
11/19/2025
Objection resolved — Addressed
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/05/2025
Permit issued — General Construction
B01312156-I1-GC
10/31/2025
Filed — Alteration
B01312156-I1
Latest 60 of 218 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedACER CONSTRUCTION INC12/22/2025
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.11/19/2025
DOB NOWGeneral ConstructionPermit IssuedACER CONSTRUCTION INC11/05/2025
DOB NOWSignSigned-offSIGNSTAR NYC10/24/2025
DOB NOWSignSigned-offSIGNSTAR NYC10/24/2025
DOB NOWSignSigned-offSIGNSTAR NYC10/24/2025
DOB NOWGeneral ConstructionSigned-offCUBE BUILDERS GROUP NY10/20/2025
DOB NOWGeneral ConstructionPermit IssuedWESBUILT CONSTRUCTION MAN10/07/2025
DOB NOWPlumbingPermit IssuedJEM FIRE PREVENTION INC03/24/2025
DOB NOWSprinklersPermit IssuedT & T PLUMBING INC03/24/2025
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION08/19/2024
DOB NOWGeneral ConstructionSigned-offSTRUCTURECRAFT CONTRACTIN12/27/2023
DOB NOWSignSigned-offACTIVE SIGNS INC01/22/2021
DOB NOWSignSigned-offACTIVE SIGNS INC01/22/2021
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC06/20/2018
BISSPISSUEDSTANDARD FIRE SUPP CORP04/11/2019
BISMHISSUEDFORTUNATO CONSTRUCTION GP04/11/2019
BISOTISSUEDFORTUNATO CONSTRUCTION GP04/11/2019
BISSPISSUEDJEM FIRE PREVENTION INC05/23/2018
BISFPISSUEDPINNACLE PLBG & HTG CORP12/08/2017
BISPLISSUEDTOP PLUMBING GROUP,INC12/06/2017
BIS—ISSUEDNIC DESIGN MGMT INC12/06/2017
BISPLISSUEDJD MASTERS PLBG & HTG08/03/2017
BISOTISSUEDFOREMOST CONSTRUCTION LLC08/03/2017
BISOTISSUEDFOREMOST CONSTRUCTION LLC08/03/2017
BISOTISSUEDFOREMOST CONSTRUCTION LLC07/18/2017
BISOTISSUEDFOREMOST CONSTRUCTION LLC07/18/2017
BIS—ISSUEDNATIONAL MAINTENANCE, INC04/14/2017
BISOTISSUEDNATIONAL MAINTENANCE INC04/14/2017
BISOTISSUEDNATIONAL MAINTENANCE INC04/14/2017
BIS—ISSUEDNATIONAL MAINTENANCE, INC04/14/2017
BISMHISSUEDA T V INC01/25/2017
BISMHISSUEDA T V INC02/11/2016
BISOTISSUEDZ-CAR-D CORP06/10/2015
BIS—ISSUEDINTERBORO SIGN & ELECL MA06/08/2015
BIS—ISSUEDRUSSCO ,INC02/25/2014
BISOTISSUEDRUSSCO ,INC01/02/2014
BISOTISSUEDRUSSCO ,INC01/02/2014
BISOTISSUEDPALADIUM BUILDERS INC12/04/2013
BISPLISSUEDTT MECHANICAL CORP11/14/2013
+ 25 more permits on file
1 project · most recent 07/01/2025
Others
FiledStatusContractorScopeMake / Model / Capacity
07/01/2025Signed-offCUBE BUILDERS GROUP NYOthers
Other
__Junk__ DRYER VENT 1 BTU ×42
1 project · most recent 07/01/2025
FiledStatusContractorScope
07/01/2025Permit IssuedJEM FIRE PREVENTION INC—
2 projects · most recent 01/23/2026
Water/Sanitary Gas
FiledStatusContractorScope
01/23/2026Permit IssuedAMERICAN STANDARD P&H CORWater/Sanitary
07/01/2025Permit IssuedT & T PLUMBING INCGas, Water/Sanitary
15 projects · most recent 04/10/2026
General Wiring
FiledStatusContractorScope
04/10/2026Permit IssuedA.C. MORGAN ELECTRICGeneral Wiring
11/12/2025Permit IssuedPROFF ELECTRICAL LLC—
11/12/2025Permit IssuedPROFF ELECTRICAL LLC—
09/24/2025Permit IssuedACCURATE ELEC'L CONTR'S CGeneral Wiring
01/17/2025CompleteR & T ELECTRICAL CORPGeneral Wiring
01/09/2024CompleteMARCEL ELEC'L CONTRG CORP—
05/02/2023CompleteDAVEN ELECTRIC CORP—
02/28/2022CompleteGOTHAM WIRING LICENSEDGeneral Wiring
04/30/2021Permit IssuedFOSTER ELEC'L SVC., INC.General Wiring
04/29/2021Permit IssuedFOSTER ELEC'L SVC., INC.General Wiring
11/02/2020Permit IssuedRAINBOW ELECTRIC CO., INC—
11/02/2020Permit IssuedRAINBOW ELECTRIC CO., INC—
05/20/2019CompleteHABER ELECTRIC CO., INC.General Wiring
11/06/2018CompleteTROON ELECTRIC OF NEW YORGeneral Wiring
12/21/2017CompleteKWONG MING ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/28/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/26/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/09/2025Pass-Final General Construction Non-Directive 14PassView ↗
05/20/2025Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
03/25/2026Public Assembly Emergency LightingJian Yangprogress
01/28/2026Energy Code Compliance InspectionsJian Yangprogress
01/28/2026Fire-Resistance Rated ConstructionJian Yangprogress
01/28/2026Fire-Resistant Penetrations and JointsJian Yangspecial
01/28/2026Electrical motors and elevatorsJian Yangenergy_progress
01/28/2026Interior lighting powerJian Yangenergy_progress
01/28/2026Lighting controlsJian Yangenergy_progress
12/09/2025FinalMatthew Dresserprogress
10/01/2025Energy Code Compliance InspectionsJian Yangprogress
10/01/2025Maintenance informationJian Yangenergy_progress
10/01/2025Fire-Resistant Penetrations and JointsJian Yangspecial
09/08/2025FinalADITYA DESAIprogress
09/03/2025FinalADITYA DESAIprogress
07/02/2025Interior lighting powerRobert Truskoskyenergy_progress
07/02/2025Finaljoongkoum kimprogress
07/02/2025Lighting controlsRobert Truskoskyenergy_progress
07/02/2025Mechanical SystemsRobert Truskoskyspecial
07/02/2025Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
05/29/2025Mechanical SystemsRobert Truskoskyspecial
05/29/2025Lighting controlsRobert Truskoskyenergy_progress
05/29/2025Interior lighting powerRobert Truskoskyenergy_progress
05/29/2025Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
05/29/2025FinalJonar Madriagaprogress
04/01/2025HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
04/01/2025Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
Latest 25 of 41.
▾Documents — 999 on file (BIS + DOB NOW)
▸Plans & Drawings23
▸DOB NOWPlans/Sketch19
09/03/2026B00052399-I1Request digital key ↗
08/26/2026B00966005-I1Request digital key ↗
08/21/2026B01063785-P4Request digital key ↗
Showing 3 of 19 on file for this type
▸DOB NOWPlans/Sketch - Sign2
09/02/2026B00388265-I1Request digital key ↗
09/02/2026B00388266-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Place of Assembly2
08/19/2026B01339459-I1Request digital key ↗
08/14/2026B01378377-I1Request digital key ↗
▸Applications & Permits197
▸BISPLAN / WORK APPROVAL APPLICATION108
05/06/2020321941556Open ↗
04/28/2020321941556Open ↗
04/28/2020321941556Open ↗
Showing 3 of 108 on file for this type
▸BISWORK PERMIT APPLICATION74
05/06/2019321941538Open ↗
04/30/2019321941556Open ↗
04/12/2019321941556Open ↗
Showing 3 of 74 on file for this type
▸BISPLACE OF ASSEMBLY6
10/02/2018321813294Open ↗
04/12/2017320196943Open ↗
Showing 2 of 6 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION4
03/28/2019321704269Open ↗
09/28/2018321525499Open ↗
09/04/2018321525499Open ↗
Showing 3 of 4 on file for this type
▸BISPLACE OF ASSEMBLY APPLICATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
11/23/2018321525499Open ↗
Showing 1 of 2 on file for this type
▸BISPLACE OF ASSEMBLY SIGN OFF1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026B01267546-I1Open ↗
08/13/2026B01267546-P2Open ↗
▸Seals & Professional Certifications253
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION131
10/07/2020321941538Open ↗
09/13/2019321704269Open ↗
09/13/2019321704269Open ↗
Showing 3 of 131 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST32
04/08/2019321941556Open ↗
02/06/2018321704269Open ↗
11/13/2017321525499Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature24
09/03/2026B00052399-I1Open ↗
08/21/2026B01063785-P3Open ↗
08/21/2026B01063785-P4Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWProgress Inspector Seal & Signature23
09/12/2026B01063785-P4Open ↗
09/12/2026B01063785-P4Open ↗
09/12/2026B01063785-P4Open ↗
Showing 3 of 23 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM17
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 17 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT10
04/08/2019321941556Open ↗
04/08/2019321941556Open ↗
11/13/2017321525499Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/12/2026B01063785-P4Open ↗
09/12/2026B01063785-P4Open ↗
08/30/2026B01063785-S2Open ↗
Showing 3 of 10 on file for this type
▸BISProfessional and Owner Certification (POC3)5
02/06/2018321704269Open ↗
07/19/2017321530054Open ↗
04/25/2017321544012Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment74
▸BISSCHEDULE B - PLUMBING20
05/06/2020321941556Open ↗
04/28/2020321941556Open ↗
Showing 2 of 20 on file for this type
▸BISSELF-CERT PLUMBING NOTICE18
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 18 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE10
04/08/2019321941556Open ↗
04/05/2019321941538Open ↗
10/09/2018321525499Open ↗
Showing 3 of 10 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA7
03/11/2021321771150Open ↗
10/15/2018321677495Open ↗
07/31/2018321689197Open ↗
Showing 3 of 7 on file for this type
▸BISEQUIPMENT USE PERMITS6
02/01/2017321492121Open ↗
Showing 1 of 6 on file for this type
▸BISEQUIPMENT USE APPLICATION-PERMIT6
02/01/2017321492121Open ↗
Showing 1 of 6 on file for this type
▸BISSIGN HANGER CERTIFICATE5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISSPRINKLER INSP REPORT : FP-852
07/18/2019321704269Open ↗
Showing 1 of 2 on file for this type
▸Safety & Tenant Protection8
▸BISSTREET TREE CHECKLIST3
12/04/2017321525499Open ↗
11/13/2017321525499Open ↗
Showing 2 of 3 on file for this type
▸BISTenant Protection Plan and Notes2
11/13/2017321525499Open ↗
07/19/2017321530054Open ↗
▸DOB NOWStreet Tree Checklist2
08/13/2026B01267546-I1Open ↗
08/13/2026B01267546-P2Open ↗
▸BISST-1 Street Tree Checklist1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos60
▸BISASBESTOS: CERTIFICATION (DEP ACP5)26
04/08/2019321941556Open ↗
04/05/2019321941538Open ↗
02/06/2018321704269Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report18
08/21/2026B01063785-P4Open ↗
08/21/2026B01063785-P3Open ↗
08/21/2026B01063785-S2Open ↗
Showing 3 of 18 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸Energy Compliance53
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS27
04/08/2019321941556Open ↗
10/02/2018321813294Open ↗
11/13/2017321525499Open ↗
Showing 3 of 27 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS14
09/18/2020321941556Open ↗
09/26/2017321530054Open ↗
02/01/2017321492121Open ↗
Showing 3 of 14 on file for this type
▸BISTR8: Energy Code Progress Inspections9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISEMERGENCY LIGHTING(IF NOT IN COMPLIANCE WITH MEMO 2/18/81)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISEMERGENCY LIGHTING (IF NOT IN COMPLIANCE WITH MEMEO 2-18-81)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY5
02/10/2021321941556Open ↗
09/22/2020321941538Open ↗
09/18/2020321941556Open ↗
Showing 3 of 5 on file for this type
▸BISMECHANICAL SYSTEMS1
05/22/2025321941556Open ↗
▸BISCertificate of Inspection Construct Manhole or Catch Basin and Basin Connection1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISTECHNICAL REPORT: CONCRETE-TEST CYLINDER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs116
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST51
11/24/2025321941556Open ↗
07/22/2021321771150Open ↗
02/10/2021321941538Open ↗
Showing 3 of 51 on file for this type
▸BISADMINISTRATIVE OBJECTIONS33
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 33 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION18
07/18/2019321704269Open ↗
07/31/2018321689197Open ↗
08/23/2017321530054Open ↗
Showing 3 of 18 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE12
08/29/2018321525499Open ↗
08/23/2018321525499Open ↗
11/13/2017321525499Open ↗
Showing 3 of 12 on file for this type
▸BISBSA-CPC APPROVAL1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISFLAME SPREAD/FIRE LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership95
▸BISCOST AFFIDAVIT95
07/14/2021321771150Open ↗
09/24/2020321941538Open ↗
09/18/2020321941556Open ↗
Showing 3 of 95 on file for this type
▸Filing & Intake Forms91
▸BISEFILING COVER SHEET56
05/31/2019321771150Open ↗
04/05/2019321941556Open ↗
04/05/2019321941556Open ↗
Showing 3 of 56 on file for this type
▸BISADDITIONAL INFORMATION28
12/13/2019321813294Open ↗
07/18/2019321704269Open ↗
06/05/2019321525499Open ↗
Showing 3 of 28 on file for this type
▸BISBOROUGH INTAKE FORM5
02/27/2020321941556Open ↗
11/23/2018321525499Open ↗
11/09/2018321525499Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Other Documents13
▸BISPlot Diagram5
11/13/2017321525499Open ↗
Showing 1 of 5 on file for this type
▸BISFIRE SUPP ANSUL APPROVL- FD-FSS2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWProperty Ownership Certification2
08/13/2026B01267546-P2Open ↗
08/13/2026B01267546-I1Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/31/2017320428168Open ↗
▸BISOP-4 - Special Report1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWPro Cert Restriction Exception (LL158/17)1
08/13/2026B01063785-S1Open ↗
▸DOB NOWAlternate Plan 11
08/14/2026B01378377-I1Open ↗