ECB10/29/2026At time of inspection observed construction site closed and unattended with no watchperson present. Building footprint was 5,135 sq. Ft. And construction operations were not in progress, contrary to bc 3303.3,$2K due
ECB10/29/2026At time of inspection, comparison of prior and current photos indicated continued exterior work at exposure #2 while partial stop work order under complaint #5192018 remained in effect, stopping exterior work i$10K due
ECB06/25/2026Knuckle boom crane sn# 1000610 was on site erecting steel.' the operator of the kb did not hold a valid new york city hmo license at time of inspection. The hmo license is required when work being performed wit$10K due
ECB06/25/2026Knuckle boom crane sn #1000610, used by golden storm const. Corp was on site erecting steel. The operator did not hold a valid NYC hmo license, there were no cert riggers involved in the crane operation and syn$10K due
ECB06/25/2026Knuckle boom crane sn# 1000610, supervised by dhc power managementwas on site erecting steel. Operator did not have valid NYC hmo license, there were no cert riggers involved in the crane operation & synthetic$10K due
ECB04/28/2026Gc fail to comply with the commissioner's order and work against stop work order issued under reference complaint# 5196065. I observe at 2 floor installation of the q -deck completed also concrete were poured,$10K due
ECB04/21/2026At time inspection observed temporary makeshift platform at elevator shaft opening at 2ND floor also supports scaffold installed on top platform 1ST floor upon request for design drawing none were provided. St$6K due
ECB04/21/2026At time of inspection observed construction fence installed at exp# 1 gate swings outward to public.$2K due
ECB04/21/2026At time of inspection active site observed missing /inadequate guardrail. Loosed horizontal safety cable throughout stop all work 2 floor and above provide adequate guardrail system throughout site.$25K due
ECB12/18/2025At time of inspection, gc 626210 failed to file a certificate of correction for the violation issued on 10/12/2025. Upon reinspection and review of BIS records, no coc was found on file. No watchperson was pres$6K due
ECB12/18/2025Gc 626210 failed to correct violation 039545920X issued on 10/12/2025. No certificate of correction is on file. The cited condition continues to exist, including an inadequate public walkway due to construction$6K due
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspection
ECB09/12/2025At time of inspection, observed work being performed at exposure 1 within 20 ft area restricted by swo issued 08/11/2025 due to lack of sidewalk shed. Shed remains not in place. Contrary to ac 28-207.2.2, respo$25K due
ECB08/11/2025At time of inspection of a 7 story building under construction, i observed building column 15 ft in height over sidewalk, and set back 1 foot from construction fence. Building is 7 feet above construction fence$25K due
ECB07/01/2025Failure to file required annual boiler inspection reports for low-pressure boiler 50000076423N0001 in accordance with the rules of the department. 1RCNY 103-01(d)(1) requires that an annual inspection report fo$3K due
DOB09/23/2024Violation issued-failure to file 2023 external low pressure inspection
ECB10/12/2025At time of inspection after walking perimeter of site and banging on fence without a response i observed there was no watch person present on site that required one. Lot area in excess of 18,000 feet with foundNothing owed — awaiting certificate of correction
ECB10/12/2025At time of inspection observed public walk was less than the required 5 foot width as per bc 3307.2.6. Walkway was approximately 3 foot wide in areas and obstructed by fire hydrant. Not maintaining a required 5Nothing owed — awaiting certificate of correction
ECB10/12/2025At time of inspection observed that there was no information panel provided for first responders to correctly identify the building while responding to an emergency creating an unsafe condition for first responNothing owed — awaiting certificate of correction
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB06/30/2023Violation issued-failure to file 2021 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB04/25/2023Violation issued-failure to file 2022 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB12/16/2022Alt co DOB now filling # S00574589-I1, which has been filed with the department on 08/11/21, is contrary to zr 32-02(d)(1), so that a special permit as per section 73-802 transient hotels is required. Therefore, the department, pursuant to ac 28-105.10.2, ordered all work, under job # S00574589, stopped immediately, except to make theIssued 2022; DOB's record still lists it as active
DOB12/16/2022Alt co DOB now filling # S00574589-I1, which has been filed with the department of on 08/11/21, is contrary to zr 32-02(d)(1), so that a special permit as per section 73-802 transient hotels is required. Therefore, the department, pursuant to ac 28-105.10.2, ordered all work, under job # S00574589, stopped immediately, except to make siteIssued 2022; DOB's record still lists it as active