Roof2p · 1 filing · 12 docs
Fire Protection
Sprinkler work modification
On file for this project
12 documents · 2 drawing sheets
Floor 333p · 2 filings · 20 docs
DMFire Protection
Herewith filing modification to Sprinkler System per plans. No changes to use, egress, or occupancy.
On file for this project
3 documents · 2 drawing sheets
Modification to HVAC system on floors: 029 & 030. Remove (3) supply 10x12 Ducts/Registers, VAV Boxes, Thermostats. New work consists of adding (3) supply Ducts/Registers, new VAV boxes , Thermostats. No change to use, egress, or occupancy.
On file for this project
17 documents · 1 drawing sheet
Floor 323p · 3 filings · 20 docs
DMFire ProtectionMechanical
Sprinkler work modification
On file for this project
12 documents · 1 drawing sheet
Herewith filing modification to Sprinkler System per plans. No changes to use, egress, or occupancy.
On file for this project
3 documents · 2 drawing sheets
Modification to HVAC system on floors: 029 & 030. Remove (3) supply 10x12 Ducts/Registers, VAV Boxes, Thermostats. New work consists of adding (3) supply Ducts/Registers, new VAV boxes , Thermostats. No change to use, egress, or occupancy.
On file for this project
17 documents · 1 drawing sheet
Floor 314p · 2 filings · 17 docs
ArchitectureFire Protection
Sprinkler work modification
On file for this project
12 documents · 1 drawing sheet
Remove drywall or glass partitions, doors, lighting, Gyp. Board ceiling, pantry finishes. New non-bearing partitions, doors, glass partitions/doors for new offices #s 1-6, File/Copy Rm., Pantry, Acoustical hung ceiling w/ Lighting, flooring as indicated.
On file for this project
5 documents · 3 drawing sheets
Floor 301p · 1 filing · 12 docs
Fire Protection
Sprinkler work modification
On file for this project
12 documents · 1 drawing sheet
Floor 291p · 1 filing · 12 docs
Fire ProtectionMechanical
Sprinkler work modification
On file for this project
12 documents · 1 drawing sheet
Floor 2816p · 3 filings · 20 docs
ArchitectureMechanicalStructural
Issued Permit Scope
General Construction · Mechanical Systems
Remove drywall or glass partitions, doors, lighting, Gyp. Board ceiling, pantry finishes. New non-bearing partitions, doors, glass partitions/doors for new offices #s 1-6, File/Copy Rm., Pantry, Acoustical hung ceiling w/ Lighting, flooring as indicated.
On file for this project
5 documents
Modification of associated ductwork for new office layout. Removal of supply ducting. registers, volume dampers, VAV boxes, ceiling diffusers, thermostats. Install new supply ducting, registers, VAV boxes, volume dampers, ceiling diffusers. thermostats.
On file for this project
7 documents
No filed description on record for this project.
On file for this project
9 documents · 1 drawing sheet
Floor 27
Floor 2624p · 5 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modification to Sprinkler System 26th Cons/29th Marketing as indicated on plans. No changes to use, egress, or occupancy
On file for this project
3 documents · 1 drawing sheet
PLUMBING MODIFICATIONS 26th Cons/29th Marketing AS INDICATED ON PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
On file for this project
5 documents
Mechanical modifications 26th Cons/29th Marketing as indicated on plans. No change in use, egress or occupancy.
On file for this project
12 documents · 2 drawing sheets
Latest 3 of 5 filings on this floor.
Floor 2532p · 5 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingOther
Issued Permit Scope
General Construction · Mechanical Systems · Sprinklers
Modify SPK system. Remove/relocate 3 , 24 new, remove 26, 0 extg. heads to remain (project area new work). Remove 1 1/2 in. SPK loop & replace w2 in. Disconnect extg. branches & reconnect new SPK main. SPK system to remain active during construction.
On file for this project
10 documents · 5 drawing sheets
Herewith filing plans plumbing work in 'New Pantry' area. Work consists of removal & replace of existing plumbing fixtures on existing roughing. See scope of work for details. No gas work or changes to use, egress or occupancy under this application.
On file for this project
7 documents · 5 drawing sheets
Modification to HVAC system. Scope includes removal ceiling diffusers & registers, VAV box. New work: ducting, ceiling diffusers, registers, VAV boxes, thermostats. Existing Mech. equipment (in Mech. Room) to remain. No changes Use,Egress or Occupancy.
On file for this project
7 documents · 4 drawing sheets
Latest 3 of 5 filings on this floor.
Floor 2415p · 4 filings · 20 docs
ArchitectureFire ProtectionMechanicalOther
Issued Permit Scope
General Construction · Mechanical Systems · Sprinklers
Sp work scope
On file for this project
8 documents · 1 drawing sheet
Interior office renovation: Minor interior demo vinyl flooring. New solid partitions w/ glass wall/doors to create new offices #5,6, Quiet office area, break out Rm. New partitions for Nursing & Copy Rms. Relocate LED lighting. New doors, floor finishes.
On file for this project
7 documents · 1 drawing sheet
Modification of SP system per plans. Demo upright & down pendant SP heads w/ branch piping. Relocate upright SP heads office #6. Add new upright SP heads in work area & open office. Add new down pendant heads nursing, copy Rms. Branch piping as indicated.
On file for this project
3 documents
Latest 3 of 4 filings on this floor.
Floor 234p · 2 filings · 13 docs
ArchitectureFire Protection
Issued Permit Scope
General Construction
Sp work scope
On file for this project
8 documents · 1 drawing sheet
PROPOSED RENOVATION OF EXISTING OFFICES ON FLOOR 22 & 23.
On file for this project
5 documents
Floor 224p · 2 filings · 11 docs
ArchitectureFire Protection
Issued Permit Scope
General Construction
SP work related to LL26/04
On file for this project
6 documents · 1 drawing sheet
PROPOSED RENOVATION OF EXISTING OFFICES ON FLOOR 22 & 23.
On file for this project
5 documents
Floor 212p · 2 filings · 11 docs
ArchitectureFire Protection
SP work related to LL26/04
On file for this project
6 documents · 1 drawing sheet
Herewith filing interior demo work of all interior offices and work areas. Scope consists in the removal of all existing partitions, doors, pantry finishes, (except for coat closets) all per plans. No change to use, egress, or occupancy.
On file for this project
5 documents · 1 drawing sheet
Floor 201p · 1 filing · 6 docs
Fire Protection
SP work related to LL26/04
On file for this project
6 documents · 1 drawing sheet
Floor 191p · 1 filing · 6 docs
Fire ProtectionPlumbing
SP work related to LL26/04
On file for this project
6 documents · 1 drawing sheet
Floor 181p · 1 filing · 6 docs
Fire Protection
SP work related to LL26/04
On file for this project
6 documents · 1 drawing sheet
Floor 171p · 1 filing · 7 docs
Fire Protection
Sprinkler work in assoc with ll2204
On file for this project
7 documents · 1 drawing sheet
Floor 161p · 1 filing · 7 docs
Fire Protection
Sprinkler work in assoc with ll2204
On file for this project
7 documents · 1 drawing sheet
Floor 151p · 1 filing · 7 docs
Fire Protection
Sprinkler work in assoc with ll2204
On file for this project
7 documents · 1 drawing sheet
Floor 141p · 1 filing · 7 docs
Fire Protection
Sprinkler work in assoc with ll2204
On file for this project
7 documents · 1 drawing sheet
Floor 132p · 2 filings · 3 docs
Fire Protection
Issued Permit Scope
Sprinklers
Project M69503019Permit Issued · 05/17/2021
SPRINKLER MODIFICATIONS TO THE 16M/13C FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
SPRINKLER MODIFICATIONS TO THE 16M/13C FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
On file for this project
3 documents
Floor 121p · 1 filing · 8 docs
Fire Protection
Sprinkler work in assoc with LL
On file for this project
8 documents · 1 drawing sheet
Floor 111p · 1 filing · 8 docs
Fire Protection
Sprinkler work in assoc with LL
On file for this project
8 documents · 1 drawing sheet
Floor 101p · 1 filing · 8 docs
Fire Protection
Sprinkler work in assoc with LL
On file for this project
8 documents · 1 drawing sheet
Floor 91p · 1 filing · 8 docs
Fire Protection
Sprinkler work in assoc with LL
On file for this project
8 documents · 1 drawing sheet
Floor 82p · 1 filing · 8 docs
Fire Protection
Sprinkler work in assoc with LL
On file for this project
8 documents · 2 drawing sheets
Floor 71p · 1 filing · 6 docs
Fire Protection
work related to LL26/04. File to correct 37022630M, 37020741X, 37015995J
On file for this project
6 documents · 1 drawing sheet
Floor 61p · 1 filing · 6 docs
Fire Protection
work related to LL26/04. File to correct 37022630M, 37020741X, 37015995J
On file for this project
6 documents · 1 drawing sheet
Floor 52p · 2 filings · 12 docs
DMFire Protection
work related to LL26/04. File to correct 37022630M, 37020741X, 37015995J
On file for this project
6 documents · 1 drawing sheet
Proposed interior demolition of existing office space. Work consists of removing partitions, doors, millwork, dropped ceiling, lighting except existing pantries, entry doors, and historical banking hall to remain. No change to use, egress or occupancy.
On file for this project
6 documents · 1 drawing sheet
Floor 43p · 1 filing · 6 docs
Fire Protection
work related to LL26/04. File to correct 37022630M, 37020741X, 37015995J
On file for this project
6 documents · 3 drawing sheets
Floor 3
Floor 25p · 1 filing · 6 docs
Fire Protection
Issued Permit Scope
Sprinklers
Sprinkler work in connection with Ll2604
On file for this project
6 documents · 1 drawing sheet
Floor 14p · 1 filing · 6 docs
Fire Protection
Issued Permit Scope
Sprinklers
Sprinkler work in connection with Ll2604
On file for this project
6 documents
Mezzanine7p · 3 filings · 11 docs
ArchitectureFire Protection
Issued Permit Scope
Sprinklers
Sprinkler work in connection with Ll2604
On file for this project
6 documents · 1 drawing sheet
SPRINKLER MODIFICATIONS TO THE (CELLAR #1-MARKETING /BAS A-CONSTRUCTION) AND (MEZZANINE - MARKETING /1ST & 2ND FLOOR-CONSTRUCTION) IN CONJUNCTION WITH THE DEMOLITION OF FM-200 SYSTEM AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
On file for this project
3 documents · 1 drawing sheet
No filed description on record for this project.
On file for this project
2 documents · 1 drawing sheet
Basement4p · 2 filings · 6 docs
ElectricalFire Protection
Sprinkler application in support of LL2204
On file for this project
4 documents · 3 drawing sheets
No filed description on record for this project.
On file for this project
2 documents · 1 drawing sheet