← Back
Walk-up cooperative
51 CHARLES STREET
MANHATTAN · BIN 1078186
💬 Discuss this project
1880Year Built
3Stories
C6Building Class
R6Zoning
4,584 sfGross Floor Area
5Units
Rent Stabilized2 Open Violations ▸
Walk-up cooperative · Owner of record: CHARLES IV INC · 1,585 sf lot · 2.89 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LAKHI GENERAL CONTRACTOR, INC407/08/2026
CHARLES V COOP603/22/2026
CHARLES IV CO-OP203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHRAF CORP105/29/2024
ACTIVE DESIGN GROUP ENGINEERING209/09/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DANICO SERVICES203/21/2026
METROPOLIS GROUP INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HCMC GROUP INCGeneral Contractor603/21/2026
DANMARC CONSTRUCTION CORPGeneral Contractor303/21/2026
LAKHI GENERAL CONTRACTORGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ACTIVE DESIGN GROUP ENGIN6666209/09/2020
Building Lifecycle
All (19)Filed (3)Permit Issued (4)Signed Off (1)Violation (4)Special Inspection (7)
10/15/2024
Signed off — Alteration
new steel lintel at window and new steel beam at roof for new roof deck.
M00381738-I1
05/30/2024
Permit issued — Sidewalk Shed
M01056315-I1-SH
05/29/2024
Filed — Alteration
M01056315-I1
05/24/2024
Permit issued — Structural
M00381738-I1-ST
05/12/2021
Violation issued (ECB, closed)
Construction
04/22/2021
Permit issued — Structural
M00381738-I1-ST
04/22/2021
Special inspection requirement — Structural Steel - Details
JOSEPH LIEBER
03/26/2021
Violation issued (ECB, closed)
Construction
11/16/2020
Permit issued — Structural
M00381738-I1-ST
09/10/2020
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOSEPH LIEBER
09/10/2020
Special inspection requirement — Masonry
JOSEPH LIEBER
09/10/2020
Special inspection requirement — Final
JOSEPH LIEBER
09/09/2020
Filed — Alteration
new steel lintel at window and new steel beam at roof for new roof deck.
M00381738-P1
09/08/2020
Special inspection requirement — Masonry
JOSEPH LIEBER
09/08/2020
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOSEPH LIEBER
09/08/2020
Special inspection requirement — Final
JOSEPH LIEBER
08/07/2020
Filed — Alteration
new steel lintel at window and new steel beam at roof for new roof deck.
M00381738-I1
03/13/1985
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/13/1985
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedLAKHI GENERAL CONTRACTOR05/30/2024
DOB NOWStructuralSigned-offHCMC GROUP INC05/24/2024
DOB NOWStructuralSigned-offHCMC GROUP INC04/22/2021
DOB NOWStructuralSigned-offDANMARC CONSTRUCTION CORP11/16/2020
BISOTISSUEDHCMC GROUP INC05/07/2024
BISOTISSUEDDANMARC CONSTRUCTION CORP02/19/2020
1 project · most recent 01/20/2020
FiledStatusContractorScope
01/20/2020CompleteANTONIO CERIELLO ELEC INC—
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
04/22/2021Structural Steel - DetailsJOSEPH LIEBERspecial
09/10/2020Structural Stability – Alterations of existing buildingsJOSEPH LIEBERspecial
09/10/2020MasonryJOSEPH LIEBERspecial
09/10/2020FinalJOSEPH LIEBERprogress
09/08/2020MasonryJOSEPH LIEBERspecial
09/08/2020Structural Stability – Alterations of existing buildingsJOSEPH LIEBERspecial
09/08/2020FinalJOSEPH LIEBERprogress
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Structural2
09/04/2026M00381738-I1Request digital key ↗
08/15/2026M00381738-P1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/27/2026M01056315-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION2
06/16/2023123895384Open ↗
02/10/2020123895384Open ↗
▸BISWORK PERMIT APPLICATION2
05/07/2024123895384Open ↗
02/21/2020123895384Open ↗
▸DOB NOWLPC Approval/Permit2
08/13/2026M00381738-P1Open ↗
08/13/2026M00381738-I1Open ↗
▸Seals & Professional Certifications13
▸DOB NOWSpecial Inspector Seal & Signature5
08/26/2026M00381738-P1Open ↗
08/26/2026M00381738-P1Open ↗
08/23/2026M00381738-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026M01056315-I1Open ↗
08/13/2026M00381738-I1Open ↗
08/13/2026M00381738-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026M00381738-P1Open ↗
08/23/2026M00381738-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/10/2020123895384Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/10/2020123895384Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/10/2020123895384Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026M00381738-P1Open ↗
08/13/2026M00381738-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/10/2020123895384Open ↗
▸Approvals, Objections & Sign-offs6
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/01/2025123895384Open ↗
▸BISLANDMARKS SIGNOFF1
05/01/2025123895384Open ↗
▸BISFINAL1
04/07/2025123895384Open ↗
▸BISLANDMARKS APPROVAL1
02/10/2020123895384Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
02/11/2020123895384Open ↗
▸BISSUPERSEDING LETTER1
05/07/2024123895384Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
02/10/2020123895384Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
05/01/2025123895384Open ↗
▸Filing & Intake Forms2
▸BISBOROUGH INTAKE FORM1
05/07/2024123895384Open ↗
▸BISEFILING COVER SHEET1
02/10/2020123895384Open ↗
▸Other Documents5
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION5
02/11/2020123895384Open ↗
02/11/2020123895384Open ↗
02/11/2020123895384Open ↗
Showing 3 of 5 on file for this type