← Back
Hospital, sanitarium, mental institution
82-68 164 STREET
QUEENS · Pomonok-Electchester-Hillcrest · BIN 4439810
💬 Discuss this project
1939Year Built
12Stories
I1Building Class
R4Zoning
1,069,367 sfGross Floor Area
1Units
LL97 Covered11 Open Violations 3 unresolved · 8 paperwork only ▸FISP: SWARMPFDNY Report ↗
Hospital, sanitarium, mental institution · 638,210 sf lot · 1.68 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Floor 442p · 1 filing · 20 docs
Floor 3
Floor 2
Floor 1
Basement4p · 2 filings · 12 docs
Sub-Basement4p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC HHC 8103/22/2026
HHC 819103/22/2026
QUEENS HOSPITAL CENTER303/21/2026
QUEENS HOSPITAL MEDICAL CENTER1603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LILKER ASSOCIATES CONSULTING ENGINE602/02/2024
HALSEY MCCORMACK HELMER INC202/02/2024
LIZARDOS ENGINEERING307/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CASO ASSOCIATES1603/21/2026
CONSTRUCTION PERMIT SERVICES603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CARE FREE ALARMS INCGeneral Contractor603/21/2026
SWEET GROUP OF NY LLCGeneral Contractor607/08/2026
ARCHER CONSULTANTS GROUPFire Protection107/08/2026
PACE PLUMBING CORPFire Protection107/08/2026
ALLIANCE PLUMBING CORPPlumbing107/08/2026
WHITESTONE PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FUTURE TECH CONSULTANTS O589502/02/2024
Building Lifecycle
All (100)Filed (11)Permit Issued (10)Signed Off (1)Facade (FISP) (3)Violation (22)Inspection (7)Objection (28)Special Inspection (18)
03/31/2026
Signed off — Alteration
Replacement of cooling unit with related dunnage work in basement data center as per plans. No change in use, egress, or occupancy.
Q00600921-I1
05/07/2025
Permit issued — Sprinklers
Q00933708-S3-EW-SP
09/04/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/29/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/30/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/22/2024
Cycle 9 facade report signed — SWARMP
07/09/2024
Cycle 9 facade report submitted
06/13/2024
Cycle 9 facade inspection completed
05/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/15/2024
Permit issued — Mechanical Systems
Q00933708-S2-MS
03/15/2024
Permit issued — General Construction
Q00933708-I1-GC
02/28/2024
Permit issued — Plumbing
Q00933708-S1-PL
02/26/2024
Permit issued — Sprinklers
Q00933708-S3-EW-SP
02/12/2024
Permit issued — Mechanical Systems
Q00933708-S2-MS
02/06/2024
Permit issued — General Construction
Q00933708-I1-GC
02/06/2024
Special inspection requirement — Sprinkler Systems
MARISA HARTE
02/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MARISA HARTE
02/06/2024
Special inspection requirement — Fire-Resistance Rated Construction
Stephen Marchese
02/06/2024
Special inspection requirement — Final
Stephen Marchese
02/06/2024
Special inspection requirement — Interior lighting power
Stephen Marchese
02/06/2024
Special inspection requirement — Lighting controls
Stephen Marchese
02/02/2024
Filed — Alteration
Related sprinkler modification for a portion of the 4 fl N building. PAA1 description in comments
Q00933708-P2
02/02/2024
Filed — Alteration
Related sprinkler modification for a portion of the 4 fl N building. PAA1 description in comments
Q00933708-P3
02/02/2024
Filed — Alteration
Related sprinkler modification for a portion of the 4 fl N building. PAA1 description in comments
Q00933708-P1
02/02/2024
Filed — Alteration
Related sprinkler modification for a portion of the 4 fl N building. PAA1 description in comments
Q00933708-P4
01/29/2024
Special inspection requirement — Maintenance information
01/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MARISA HARTE
01/29/2024
Special inspection requirement — Final
Stephen Marchese
01/29/2024
Special inspection requirement — Sprinkler Systems
01/29/2024
Special inspection requirement — Lighting controls
Stephen Marchese
01/29/2024
Special inspection requirement — Interior lighting power
Stephen Marchese
01/29/2024
Special inspection requirement — Fire-Resistance Rated Construction
Stephen Marchese
01/29/2024
Special inspection requirement — Mechanical Systems
01/29/2024
Special inspection requirement — Post-installed Anchors
01/29/2024
Special inspection requirement — Final
01/29/2024
Special inspection requirement — Duct leakage testing, insulation and design
01/29/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
01/09/2024
Objection resolved — Addressed
01/09/2024
Objection resolved — Addressed
01/09/2024
Objection resolved — Addressed
01/09/2024
Objection resolved — Addressed
12/21/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/20/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/01/2023
Objection raised — Other
11/28/2023
Objection raised — Scope
11/28/2023
Objection raised — Admin
11/22/2023
Objection resolved — Addressed
11/17/2023
Objection resolved — Addressed
11/14/2023
Filed — Alteration
Related sprinkler modification for a portion of the 4 fl N building. PAA1 description in comments
Q00933708-S1
11/08/2023
Objection resolved — Addressed
11/08/2023
Objection resolved — Addressed
11/08/2023
Objection resolved — Addressed
11/08/2023
Objection resolved — Addressed
11/08/2023
Objection resolved — Addressed
10/27/2023
Objection raised — Scope
10/26/2023
Objection raised — Other
10/26/2023
Objection raised — Fire_Protection
10/26/2023
Objection raised — Structural
10/26/2023
Objection raised — Structural
10/26/2023
Objection raised — Scope
Latest 60 of 100 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offARCHER CONSULTANTS GROUP05/07/2025
DOB NOWMechanical SystemsPermit IssuedSWEET GROUP OF NY LLC03/15/2024
DOB NOWGeneral ConstructionPermit IssuedSWEET GROUP OF NY LLC03/15/2024
DOB NOWPlumbingSigned-offCARDOZA PLUMBING WMBE02/28/2024
DOB NOWSprinklersSigned-offMANENGEERING BUREAU, INC02/26/2024
DOB NOWMechanical SystemsPermit IssuedSWEET GROUP OF NY LLC02/12/2024
DOB NOWGeneral ConstructionPermit IssuedSWEET GROUP OF NY LLC02/06/2024
DOB NOWPlumbingPermit IssuedWHITESTONE PLUMBING CORP09/29/2023
DOB NOWMechanical SystemsSigned-offCARE FREE ALARMS INC09/21/2023
DOB NOWMechanical SystemsSigned-offCARE FREE ALARMS INC09/20/2022
BISOTISSUEDVASTECH CONTRACTING CORP12/26/2017
BISSDISSUEDNYC HEALTH & HOSP. CORP02/08/2012
BIS—ISSUEDNYC HEALTH & HOSPITALS CORPORATI10/07/2003
BISOTISSUEDNYC HEALTH & HOSPITALS CORP10/07/2003
BISOTISSUEDNYC HEALTH & HOSPITALS CORP10/07/2003
BISMHISSUEDNYC HEALTH & HOSPITALS CORP10/07/2003
BISPLISSUEDNYC HEALTH & HOSP CORP10/07/2003
BISPLISSUEDRICHARDS PLBG & HTG CO INC10/02/2003
BISSPISSUEDNYCHHC08/28/2003
BISMHISSUEDNYC HEALTH & HOSPITALS CORPORATI05/21/2003
BISOTISSUEDNYC HEALTH AND HOSPITAL04/11/2003
BISPLISSUEDNYC HEALTH & HOSPITAL CO04/11/2003
BISOTISSUEDNYC HEALTH AND HOSPITAL04/11/2003
BISOTISSUEDHELLMAN CONSTRUCTION CO10/22/1998
BISFPISSUEDSAFETY CONSULTANS ,INC09/19/1997
BISPLISSUEDFORSYTHE P&H CORP10/03/1991
BISOTISSUEDSUPER STRUCT CO08/06/1991
1 project · most recent 02/02/2024
Sprinkler System
FiledStatusContractorScope
02/02/2024Signed-offARCHER CONSULTANTS GROUPSprinkler System
2 projects · most recent 02/02/2024
Water/Sanitary
FiledStatusContractorScope
02/02/2024Signed-offALLIANCE PLUMBING CORPWater/Sanitary
07/17/2023Permit IssuedWHITESTONE PLUMBING CORPWater/Sanitary
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
09/04/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/29/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/30/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/21/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/20/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
02/06/2024Sprinkler SystemsMARISA HARTEspecial
02/06/2024Fire-Resistant Penetrations and JointsMARISA HARTEspecial
02/06/2024Fire-Resistance Rated ConstructionStephen Marcheseprogress
02/06/2024FinalStephen Marcheseprogress
02/06/2024Interior lighting powerStephen Marcheseenergy_progress
02/06/2024Lighting controlsStephen Marcheseenergy_progress
01/29/2024Maintenance information—energy_progress
01/29/2024Fire-Resistant Penetrations and JointsMARISA HARTEspecial
01/29/2024FinalStephen Marcheseprogress
01/29/2024Sprinkler Systems—special
01/29/2024Lighting controlsStephen Marcheseenergy_progress
01/29/2024Interior lighting powerStephen Marcheseenergy_progress
01/29/2024Fire-Resistance Rated ConstructionStephen Marcheseprogress
01/29/2024Mechanical Systems—special
01/29/2024Post-installed Anchors—special
01/29/2024Final—progress
01/29/2024Duct leakage testing, insulation and design—energy_progress
01/29/2024HVAC-R and service water piping design and insulation—energy_progress
▾Documents — 105 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/23/2026Q00933708-S2Request digital key ↗
08/23/2026Q00933708-I1Request digital key ↗
08/23/2026Q00933708-S1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION5
10/05/2017440429537Open ↗
10/28/2016421379001Open ↗
02/04/2013420316633Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION1
02/08/2012420316633Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
10/28/2016421379001Open ↗
▸Seals & Professional Certifications22
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/27/2026Q00600940-I1Open ↗
08/23/2026Q00933708-I1Open ↗
08/23/2026Q00933708-S1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/26/2026Q00933708-P1Open ↗
08/26/2026Q00933708-P1Open ↗
08/25/2026Q00933708-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
12/22/2018440429537Open ↗
02/08/2012420316633Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q00933708-S3Open ↗
08/25/2026Q00933708-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/05/2017440429537Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/05/2017440429537Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/05/2017440429537Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING3
02/04/2013420316633Open ↗
11/15/2012420316633Open ↗
01/19/2011420316633Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
07/26/2011420316633Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/23/2026Q00933708-S1Open ↗
08/23/2026Q00933708-S2Open ↗
08/23/2026Q00933708-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/29/2011420316633Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/28/2016421379001Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
10/05/2017440429537Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/15/2026Q00600921-I1Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/26/2017440429537Open ↗
10/05/2017440429537Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/22/2018440429537Open ↗
▸BISNYCECC ANALYSIS1
10/05/2017440429537Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/22/2018440429537Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/05/2017440429537Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
12/26/2017440429537Open ↗
12/26/2017440429537Open ↗
12/26/2017440429537Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs29
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter11
08/14/2026Q00600940-I1Open ↗
08/13/2026Q00933708-P1Open ↗
08/13/2026Q00933708-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)8
08/13/2026Q00933708-P2Open ↗
08/13/2026Q00933708-S3Open ↗
08/13/2026Q00933708-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)4
08/13/2026Q00933708-I1Open ↗
08/13/2026Q00933708-S1Open ↗
08/13/2026Q00933708-S2Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
12/22/2018440429537Open ↗
01/19/2011420316633Open ↗
01/19/2011420316633Open ↗
▸DOB NOWDEP Variance (V5) letter2
08/13/2026Q00600940-I1Open ↗
08/13/2026Q00600921-I1Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/09/2019440429537Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
12/22/2018440429537Open ↗
10/05/2017440429537Open ↗
10/28/2016421379001Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET2
10/28/2016421379001Open ↗
01/19/2011420316633Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/05/2017440429537Open ↗
▸BISADDITIONAL INFORMATION1
07/26/2011420316633Open ↗
▸BISBOROUGH INTAKE FORM1
12/22/2018440429537Open ↗