DOB09/15/2025PROVIDE ADDITIONAL INFORMATION.2NDFL W14 SPANDREL ABVE 1STFL PRKING@ EXP3 WAL&MASNRY WALL WAS STRUCTT CMPRMSD IN APRIL 2023.EXISTING 2NDFL CONN1 STRUCT ADEQUACY@(2) W12X96 BEAMS SPPRT EXP3W14X176 IN QSTN.OWNR TO RTAIN NYSPE TO PRVDE DTAILD S&S ENGNEERNG RPRT VERIFYNG THE CNDITIONS OF STRUCT FRAME@BOTH EXP1&3 WALLS
DOB09/13/2023OWNR TO RTAIN NYS PE TO EVAL THE ENT BLDG,RPAIR,FILE DRWNGS W/DOB STRT WORK UNDR PRMT BY 5/22/23 AND COMPLETED/SIGNED OFF BY JUNE30,2023 COMPLY W/COMMISSIONER ORDER #341386(041723FEU31302PN)DATED APRIL 17, 2023 TOP RPAIR BUILDING UNDER PERMIT IMMEDIATELY
DOB04/17/2023FTM.EXP2&4 MASONRY BEARING WALLS CRCKD&SPALLNG@EXP3,2FL SPANDREL HORIZONTAL&VERT CRCKS@EXP3,2FL EXT BRICK&BACKUP CMU WALL NEAR CENTER OF WALL;MASONRY PIERS BTWN WNDWS&DOOR CRCKD/RACKD.INT WALLS/CEILING CRCKS@2FL EXP3 W/RACKD DOORS&WNDWS@APT#2.OWNR TO RTAIN NYS PE TO EVAL ENT BLDG,RPAIR FILE DRWNGS W/DOB.STRT WRK UNDR PRMT BY 5/22/23&CMPLTD
DOB04/13/2023FAILURE TO MAINTAIN BUILDING WALLS/APPURTENANCES REAR WALL OF FIVE STORY M/D IN A STATE OF DISREPAIR WITH LARGE CRACKS BULGING AND STRUCTURALLY DEFECTIVE WINDOW FRAMES AND DOOR FRAMES WARPED AND CRACKED MASONARY WINDOW SILLS LARGE STRUCTURAL CRACKS
HPD07/12/2017§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT WALL AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT WALL AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT WALL AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD07/12/2017§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
ECB06/14/2024FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-00977, DATED 4/13/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIOND. AS OF 10/11/20Nothing owed — awaiting certificate of correction
ECB12/12/2002FAILURE TO PROVIDE 24 HR NOTICE. UPON INSP AT ABOVE PROPERTY BUILDING WAS DECRIDSHED AND DOB RECORDS SHOWS AS 24 HR NOTICE HAS BEEN PROVIDED. REMEDY; NOTIFY DOB AS PER CODE.Nothing owed — awaiting certificate of correction