← Back
Elevator cooperative
1178 MADISON AVENUE
MANHATTAN · BIN 1046849
💬 Discuss this project
1926Year Built
15Stories
D4Building Class
C5-1Zoning
263,334 sfGross Floor Area
110Units
LL97 CoveredRent Stabilized15 Open Violations 9 unresolved · 6 paperwork only ▸FISP: SWARMP
Elevator cooperative · Owner of record: 25 EAST 86TH ST. COR · 20,253 sf lot · 13 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction23p · 2 filings · 20 docs
Penthouse1p · 2 filings · 20 docs
Floor 153p · 2 filings · 20 docs
Floor 142p · 2 filings · 20 docs
Floor 13Under Construction28p · 5 filings · 20 docs
Floor 122p · 2 filings · 20 docs
Floor 11
Floor 10
Floor 9
Floor 8
Floor 72p · 2 filings · 10 docs
Floor 6Under Construction7p · 2 filings · 16 docs
Floor 58p · 4 filings · 20 docs
Floor 4Under Construction4p · 2 filings · 20 docs
Floor 3Under Construction11p · 4 filings · 20 docs
Floor 21p · 1 filing · 20 docs
Floor 1Under Construction16p · 3 filings · 20 docs
Cellar1p · 1 filing · 20 docs
Sub-Cellar2p · 2 filings · 20 docs
5 jobs · most recent 06/03/2026
Heating and Air Conditioning Systems Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/03/2026Permit IssuedZ S NY IMPROVEMENT CORPAir Conditioning Systems
Cooling
Mitsubishi Electric PVFY-P30NAMU-E1 30,000 BTU · Vrf Indoor ×2
MXZSM60NL 60,000 BTU · Condensing Unit ×1
03/06/2026Permit IssuedATLANTIDA HVAC CORPHeating and Air Conditioning Systems
Heat / Cool
Daikin FXSQ36TAVJU 1,130 CFM · Vrf Indoor ×6
RXYQ96AATJA 96,000 BTU · Vrf Outdoor ×2
12/11/2025Permit IssuedARNICA HEATING & AIR CONDHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI MXZ-SM48NLHZ 48,000 BTU/H HYPER HEAT PUMP OUTDOOR UNIT 48,000 BTU · Heat Pump Outdoor ×1
08/22/2025Permit IssuedATLANTIDA HVAC CORPHeating and Air Conditioning Systems
Heat / Cool
Daikin FXTQ36TAVJU 1,050 CFM · Vrf Indoor ×3
RXTQ60TBVJUB 57,000 BTU · Vrf Outdoor ×2
FXSQ36TAVJU 1,130 CFM · Vrf Indoor ×1
07/24/2025Permit IssuedCGR SYSTEMS MANAGEMENTHeating and Air Conditioning Systems
Heat / Cool
Task TGC021TWEC-30K-3622 29,900 BTU · Condensing Unit ×2
6 jobs · most recent 06/17/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/17/2026Signed-offBELL FUEL OIL, LLCGas
11/20/2025Signed-offPROSTAR PLUMBING AND HEATGas, Water/Sanitary
07/24/2025Permit IssuedDONATO PLUMBING, INCGas, Water/Sanitary
06/10/2025Permit IssuedGOLDS PLUMBING CORPGas, Water/Sanitary
10/01/2020Signed-offALKLEM PLUMBING INCGas, Water/Sanitary
03/13/2020Permit IssuedCOCHRANE PLBG & HTGGas, Water/Sanitary
25 jobs · most recent 06/10/2026
General Wiring Lighting
FiledStatusContractorScope
06/10/2026CompleteINDY ELECTRIC CORP.General Wiring
04/25/2026Permit IssuedJAM ELECTRICAL CORP—
03/03/2026CompleteALL CITY ELECTRICAL INC—
02/25/2026CompleteALL CITY ELECTRICAL INC—
01/09/2026Permit IssuedSUPREME ELECTRIC CORPGeneral Wiring
12/18/2025CompleteH POWER ELECTRIC INCGeneral Wiring
10/30/2025Permit IssuedBASS ELECTRICAL CORP.General Wiring
10/16/2025CompleteULTRA ELECTRIC CORPGeneral Wiring
09/19/2025Permit IssuedBIG CITY ELECL SOLUTIONSGeneral Wiring
07/14/2025CompleteALL CITY ELECTRICAL INC—
07/11/2025Permit IssuedBIG CITY ELECL SOLUTIONSGeneral Wiring
04/24/2025CompleteSMART ELECTRIC SERVICES—
10/22/2024Permit IssuedHYLAN DATACOM & ELECL LLC1 meters, 1 new_meters
03/14/2024CompleteC & A ELECTRICAL CORPGeneral Wiring
06/12/2023CompleteINDY ELECTRIC CORP.1 meters, 1 new_meters
1 job · most recent 12/11/2025
FiledStatusContractorScope
12/11/2025Permit IssuedARNICA HEATING & AIR COND1 scope_items
1 job · most recent 11/15/2017
Fence
FiledStatusContractorScope
11/15/2017Permit IssuedKING ROSE OF NY, INCFence
2 jobs · most recent 03/06/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
03/06/2026Permit IssuedATLANTIDA HVAC CORPTenant Protection Plan 72 Hour
08/22/2025Permit IssuedATLANTIDA HVAC CORPTenant Protection Plan 72 Hour
Building Lifecycle
All (300)Filed (56)Permit Issued (53)Signed Off (16)Facade (FISP) (9)Violation (41)Inspection (51)Objection (44)Special Inspection (30)
08/20/2026
Permit issued — Mechanical Systems
M01408869-I1-GC
08/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/10/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/04/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/07/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/18/2026
Permit issued — General Construction
M01211053-I1-GC
06/17/2026
Filed — Alteration
NEW 14 GAGE WELDED BREACHING. NO CHANGE IN MEANS OF EGRESS, USE GROUP OR OCCUPANCY.
M01280402-P3
06/17/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Germain Jr.
06/16/2026
Permit issued — General Construction
M01408869-I1-MS
06/16/2026
Permit issued — General Construction
M01408869-I1-GC
06/10/2026
Objection resolved — Addressed
06/10/2026
Objection resolved — Addressed
06/10/2026
Objection resolved — Addressed
06/10/2026
Objection resolved — Addressed
06/09/2026
Objection raised — Scope
06/09/2026
Objection raised — Inspections
06/09/2026
Objection raised — Scope
06/09/2026
Objection raised — Other
06/04/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/03/2026
Filed — Alteration
Minor interior partition changes and installation of AC units and associated ductwork, as per plans. No change to use, egress or occupancy.
M01408869-I1
05/29/2026
Special inspection requirement — Maintenance information
LAWRENCE GREEN
05/29/2026
Special inspection requirement — HVAC-R and service water heating equipment
LAWRENCE GREEN
05/29/2026
Special inspection requirement — Duct leakage testing, insulation and design
LAWRENCE GREEN
05/29/2026
Special inspection requirement — Fire-Resistance Rated Construction
LAWRENCE GREEN
05/29/2026
Special inspection requirement — HVAC-R and service water heating system controls
LAWRENCE GREEN
05/29/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
LAWRENCE GREEN
05/28/2026
Special inspection requirement — Mechanical Systems
LAWRENCE GREEN
05/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
LAWRENCE GREEN
05/28/2026
Special inspection requirement — Final
LAWRENCE GREEN
05/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/08/2026
Signed off — Alteration
Propose mechanical work @ partial 5th floor Apt#5G in conjunction with application #M01217468 as per plan. No change in use, egress, or occupancy.
M01234930-I1
05/04/2026
Permit issued — General Construction
M01280402-I1-GC
05/01/2026
Signed off — Alteration
Propose plumbing work @ partial 5th floor Apt#5G as per plan. No change in use, egress, or occupancy.
M01217468-I1
05/01/2026
Signed off — Alteration
Propose plumbing work @ partial 5th floor Apt#5G as per plan. No change in use, egress, or occupancy.
M01217468-S1
05/01/2026
Permit issued — Plumbing
M01280402-S1-PL
04/28/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/28/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/24/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/24/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/23/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/23/2026
Special inspection requirement — Final
Robert Germain Jr.
04/23/2026
Special inspection requirement — Tenant Protection Plan Compliance
Robert Germain Jr.
04/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Germain Jr.
04/23/2026
Special inspection requirement — Chimneys and vents
Robert Germain Jr.
04/22/2026
Filed — Alteration
NEW 14 GAGE WELDED BREACHING. NO CHANGE IN MEANS OF EGRESS, USE GROUP OR OCCUPANCY.
M01280402-P1
04/22/2026
Filed — Alteration
NEW 14 GAGE WELDED BREACHING. NO CHANGE IN MEANS OF EGRESS, USE GROUP OR OCCUPANCY.
M01280402-P2
04/16/2026
Special inspection requirement — Final
Robert Germain Jr.
04/16/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/16/2026
Special inspection requirement — Chimneys and vents
Robert Germain Jr.
04/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Germain Jr.
04/13/2026
Signed off — Alteration
M01002232-I1
04/06/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/25/2026
Signed off — Alteration
M01237450-I1
03/24/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/16/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Obaid Mian
03/16/2026
Special inspection requirement — HVAC-R and service water heating system controls
Obaid Mian
03/16/2026
Special inspection requirement — Maintenance information
Obaid Mian
03/16/2026
Special inspection requirement — Tenant Protection Plan Compliance
Max Lee
Latest 60 of 300 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ORSID NY2408/29/2026
JEFFREY R SCHLANGER 2012 TRUST1207/08/2026
25 EAST 86TH ST. COR403/22/2026
25 E 86 ST1003/22/2026
25 E 86 ST COR103/22/2026
25 EAST 86 STREET6003/22/2026
25 EAST 85 STREET CORPORA103/22/2026
25 EAST 86TH ST CORP C O ORSID1303/22/2026
TOWER BLDG RESTORATION103/22/2026
ORISO REALTY CORP103/22/2026
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DECORATIVE DESIGN CONSTRUGeneral Contractor707/08/2026
LEMESOS INCGeneral Contractor507/08/2026
WOODFIELD DESIGN BUILD LLGeneral Contractor407/08/2026
ROCKAWAY CUSTOM CABINETSGeneral Contractor303/21/2026
ALKLEM PLUMBING INCPlumbing307/08/2026
KING ROSE OF NY, INCGeneral Contractor303/21/2026
KAYAFAS CONTR. CO. INCGeneral Contractor304/09/2026
KAYAFAS CONTRACTING CO I*General Contractor304/09/2026
ADRIATIC PLBG & HTG CORPPlumbing207/08/2026
INDY ELECTRIC CORP.Electrical203/22/2026
ARNICA HEATING & AIR CONDGeneral Contractor203/21/2026
ATLANTIDA HVAC CORPGeneral Contractor207/08/2026
CGR SYSTEMS MANAGEMENTGeneral Contractor207/08/2026
KITCHENS ETC INCGeneral Contractor203/21/2026
Z S NY IMPROVEMENT CORPGeneral Contractor208/21/2026
COCHRANE PLBG & HTGPlumbing207/08/2026
TRI CITY MECHANICAL GROUP CORPPlumbing207/08/2026
ZITO, ROCCOElectrical103/21/2026
HUDSON PLMBING & MCH, LLCPlumbing106/28/2026
JUST PLBG & HTG INCPlumbing107/08/2026
BELL FUEL OIL LLCGeneral Contractor106/02/2026
BOBBY J. ENTERPRISE INCGeneral Contractor107/08/2026
NEW YORK PARK PLBG&HTG COPlumbing107/08/2026
CLEARCUT GROUP CORPGeneral Contractor104/09/2026
GORMAN, BARTHOLOMEWElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ROBERT F. GERMAIN JR. PE5100506/17/2026
JACK GREEN ASSOCIATES422406/03/2026
OBAID MIAN849303/06/2026
MICHAEL TOWER ARCHITECTUR8029201/30/2026
ACE STRUCTURAL ENGINEERIN496201/30/2026
KZ ENGINEERING, P.C.4665112/11/2025
BEYOND ARCH LLC3600212/11/2025
AG ENGINEERING PLLC8899311/20/2025
AA BUILDING & INSPECTION1519509/10/2025
PROJECT TACTICAL SOLUTION5859208/22/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedZ S NY IMPROVEMENT CORP08/20/2026
DOB NOWGeneral ConstructionPermit IssuedCGR SYSTEMS MANAGEMENT06/18/2026
DOB NOWGeneral ConstructionPermit IssuedHAMILTON AIR COMPANY, INC.06/16/2026
DOB NOWGeneral ConstructionPermit IssuedZ S NY IMPROVEMENT CORP06/16/2026
DOB NOWGeneral ConstructionSigned-offBELL FUEL OIL LLC05/04/2026
DOB NOWPlumbingSigned-offBELL FUEL OIL, LLC05/01/2026
DOB NOWPlumbingPermit IssuedNEW YORK PARK PLBG&HTG CO02/03/2026
DOB NOWGeneral ConstructionSigned-offKAYAFAS CONTRACTING CO I*01/23/2026
DOB NOWPlumbingPermit IssuedMOHAMED ABDELRAZEK01/09/2026
DOB NOWMechanical SystemsPermit IssuedARNICA HEATING AIR COND01/09/2026
DOB NOWGeneral ConstructionPermit IssuedCLEARCUT GROUP CORP01/08/2026
DOB NOWGeneral ConstructionPermit IssuedMON-RAD INC12/19/2025
DOB NOWGeneral ConstructionPermit IssuedCGR SYSTEMS MANAGEMENT12/18/2025
DOB NOWGeneral ConstructionSigned-offKAYAFAS CONTRACTING CO I*11/28/2025
DOB NOWGeneral ConstructionPermit IssuedRAEL AUTOMATIC SPRINKLER CO., INC.11/05/2025
DOB NOWGeneral ConstructionSigned-offWOODFIELD DESIGN BUILD LL11/05/2025
DOB NOWMechanical SystemsSigned-offWOODFIELD DESIGN BUILD LL11/05/2025
DOB NOWGeneral ConstructionSigned-offKAYAFAS CONTR. CO. INC10/27/2025
DOB NOWMechanical SystemsPermit IssuedATLANTIDA HVAC10/24/2025
DOB NOWPlumbingPermit IssuedDONATO PLUMBING, INC10/22/2025
DOB NOWMechanical SystemsPermit IssuedATLANTIDA HVAC10/21/2025
DOB NOWPlumbingPermit IssuedHUDSON PLMBING & MCH, LLC09/23/2025
DOB NOWGeneral ConstructionPermit IssuedTRIESTE CONSTRUCTION CORP09/17/2025
DOB NOWPlumbingSigned-offFLAVIO MECHANICAL CORP07/28/2025
DOB NOWPlumbingSigned-offPROSTAR PLUMBING AND HEAT07/15/2025
DOB NOWGeneral ConstructionSigned-offWOODFIELD DESIGN BUILD LL07/15/2025
DOB NOWMechanical SystemsSigned-offWOODFIELD DESIGN BUILD LL07/15/2025
DOB NOWGeneral ConstructionSigned-offKAYAFAS CONTR. CO. INC07/14/2025
DOB NOWPlumbingSigned-offFLAVIO MECHANICAL CORP03/22/2024
DOB NOWMechanical SystemsSigned-offFT'S PRECISE HEATING &03/22/2024
DOB NOWGeneral ConstructionSigned-offROCKAWAY CUSTOM CABINETS03/06/2024
DOB NOWGeneral ConstructionSigned-offLEMESOS INC01/19/2023
DOB NOWPlumbingSigned-offADRIATIC PLBG & HTG CORP01/06/2023
DOB NOWGeneral ConstructionSigned-offDECORATIVE DESIGN CONSTRU12/21/2022
DOB NOWMechanical SystemsSigned-offDECORATIVE DESIGN CONSTRU12/21/2022
DOB NOWPlumbingSigned-offALLEGIANCE PLBG & HTG COR10/25/2022
DOB NOWGeneral ConstructionSigned-offKITCHENS ETC INC10/24/2022
DOB NOWMechanical SystemsSigned-offDECORATIVE DESIGN CONSTRU10/20/2022
DOB NOWGeneral ConstructionSigned-offDECORATIVE DESIGN CONSTRU10/20/2022
DOB NOWPlumbingSigned-offMATHEW WEISS09/03/2022
+ 60 more permits on file
▾Field Inspections (DOB CAP) — 51
DateTypeResultReport
08/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/10/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/04/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/07/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/04/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/28/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/28/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/24/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/24/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/23/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/06/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/24/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/27/2026Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
02/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/27/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/12/2026Fail-Final CND-Occupancy InspectionFailView ↗
02/11/2026Pass-Final CND-Occupancy InspectionPassView ↗
02/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/23/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/09/2026Pass-Final SP - Up to 3 Requested FloorsPassView ↗
Latest 25 of 51.
▾Special Inspection Requirements (DOB NOW) — 110
DateRequirementInspectorRole
06/17/2026Fire-Resistant Penetrations and JointsRobert Germain Jr.special
06/17/2026Tenant Protection Plan Compliance—special
05/29/2026HVAC-R and service water heating system controlsLAWRENCE GREENenergy_progress
05/29/2026HVAC-R and service water heating equipmentLAWRENCE GREENenergy_progress
05/29/2026Duct leakage testing, insulation and designLAWRENCE GREENenergy_progress
05/29/2026HVAC-R and service water piping design and insulationLAWRENCE GREENenergy_progress
05/29/2026Fire-Resistance Rated ConstructionLAWRENCE GREENprogress
05/29/2026Maintenance informationLAWRENCE GREENenergy_progress
05/28/2026Fire-Resistant Penetrations and JointsLAWRENCE GREENspecial
05/28/2026Mechanical SystemsLAWRENCE GREENspecial
05/28/2026FinalLAWRENCE GREENprogress
04/23/2026Tenant Protection Plan ComplianceRobert Germain Jr.special
04/23/2026FinalRobert Germain Jr.progress
04/23/2026Fire-Resistant Penetrations and JointsRobert Germain Jr.special
04/23/2026Chimneys and ventsRobert Germain Jr.special
04/16/2026Tenant Protection Plan Compliance—special
04/16/2026Fire-Resistant Penetrations and JointsRobert Germain Jr.special
04/16/2026Chimneys and ventsRobert Germain Jr.special
04/16/2026FinalRobert Germain Jr.progress
03/16/2026HVAC-R and service water heating system controlsObaid Mianenergy_progress
03/16/2026HVAC-R and service water piping design and insulationObaid Mianenergy_progress
03/16/2026Tenant Protection Plan ComplianceMax Leespecial
03/16/2026Mechanical SystemsObaid Mianspecial
03/16/2026FinalObaid Mianprogress
03/16/2026HVAC-R and service water heating equipmentObaid Mianenergy_progress
Latest 25 of 110.
▾Documents — 1,519 on file (BIS + DOB NOW)
▸Plans & Drawings57
▸DOB NOWPlans/Sketch53
09/06/2026M00001716-I1Request digital key ↗
09/02/2026M00703501-I1Request digital key ↗
09/02/2026M00730437-I1Request digital key ↗
Showing 3 of 53 on file for this type
▸DOB NOWPlans/Sketch - Plumbing3
09/05/2026M00305687-I1Request digital key ↗
09/04/2026M00226764-I1Request digital key ↗
09/04/2026M00226764-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/05/2026M00227239-I1Request digital key ↗
▸Applications & Permits291
▸BISWORK PERMIT APPLICATION152
09/28/2023100293424Open ↗
03/06/2020123885876Open ↗
11/07/2019123748089Open ↗
Showing 3 of 152 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION134
02/02/2026102526189Open ↗
01/26/2026102526189Open ↗
01/23/2026102526189Open ↗
Showing 3 of 134 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISAFTER-HOUR WORK PERMIT APPLICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
10/04/2017140654183Open ↗
▸Seals & Professional Certifications372
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION168
03/06/2020123885876Open ↗
02/20/2020123510931Open ↗
02/20/2020123510931Open ↗
Showing 3 of 168 on file for this type
▸DOB NOWProgress Inspector Seal & Signature64
09/23/2026M01264696-I1Open ↗
09/23/2026M01265195-I1Open ↗
09/23/2026M01264696-I1Open ↗
Showing 3 of 64 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature57
09/06/2026M00001716-I1Open ↗
09/04/2026M00226764-I1Open ↗
09/04/2026M00226764-P1Open ↗
Showing 3 of 57 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature36
09/23/2026M01264696-I1Open ↗
09/23/2026M01002220-P1Open ↗
09/23/2026M01252599-S2Open ↗
Showing 3 of 36 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST15
03/06/2020123885876Open ↗
Showing 1 of 15 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM14
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 14 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT8
03/06/2020123885876Open ↗
11/10/2017140715171Open ↗
10/30/2017140709990Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY4
11/10/2017140715171Open ↗
10/30/2017140709990Open ↗
Showing 2 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION4
11/10/2017140715171Open ↗
10/30/2017140709990Open ↗
Showing 2 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
11/06/2017140712708Open ↗
Showing 1 of 2 on file for this type
▸Trade Schedules & Equipment133
▸BISSELF-CERT PLUMBING NOTICE46
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 46 on file for this type
▸BISSCHEDULE B - PLUMBING32
04/26/2018140712708Open ↗
04/03/2018140712708Open ↗
11/10/2017140715171Open ↗
Showing 3 of 32 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE24
04/22/2019123510931Open ↗
12/17/2018123510931Open ↗
04/26/2018123501111Open ↗
Showing 3 of 24 on file for this type
▸BISEQUIPMENT USE PERMITS15
04/17/2018123350747Open ↗
04/17/2018123350747Open ↗
Showing 2 of 15 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT12
04/17/2018123350747Open ↗
04/17/2018123350747Open ↗
Showing 2 of 12 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
01/08/2021140712708Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection16
▸BISTenant Protection Plan and Notes9
03/06/2020123885876Open ↗
10/25/2019123748089Open ↗
12/17/2018123510931Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWTenant Protection Plan4
09/04/2026M00226764-I1Open ↗
09/04/2026M00226764-P1Open ↗
Showing 2 of 4 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸Environmental & Asbestos132
▸DOB NOWDEP ACP-5: Asbestos Assessment Report42
09/04/2026M00226764-P1Open ↗
09/04/2026M00226764-I1Open ↗
09/02/2026M00745518-I1Open ↗
Showing 3 of 42 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)38
10/25/2019123748089Open ↗
01/09/2019123510931Open ↗
07/20/2018123501111Open ↗
Showing 3 of 38 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'23
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 23 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER13
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 13 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form11
08/28/2026M01002220-I1Open ↗
08/28/2026M01002232-I1Open ↗
08/23/2026M01235428-S1Open ↗
Showing 3 of 11 on file for this type
▸BISASBESTOS-WORK UNDET 1000 SQ FT (DEP ACP7)2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP 20-21-5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance115
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS67
03/06/2020123885876Open ↗
02/20/2020123510931Open ↗
02/20/2020123510931Open ↗
Showing 3 of 67 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS27
01/08/2021140712708Open ↗
02/20/2020123510931Open ↗
02/06/2020123510931Open ↗
Showing 3 of 27 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY6
01/08/2021140712708Open ↗
11/10/2017140715171Open ↗
11/06/2017140712708Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISTR8: Energy Code Progress Inspections5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸DOB NOWEN2: As Built Energy Analysis3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/10/2017140715171Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports12
▸BISTECHNICAL REPORT: RESPONSIBILITY10
11/29/2023100293424Open ↗
01/08/2021140712708Open ↗
11/10/2017140715171Open ↗
Showing 3 of 10 on file for this type
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19752
02/13/2026102526189Open ↗
11/29/2023100293424Open ↗
▸Approvals, Objections & Sign-offs107
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST55
02/17/2026102526189Open ↗
12/05/2023100293424Open ↗
01/08/2021140712708Open ↗
Showing 3 of 55 on file for this type
▸BISADMINISTRATIVE OBJECTIONS29
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 29 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION19
05/16/2018123435586Open ↗
05/16/2018123435586Open ↗
12/15/2017102640536Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWDEP Variance (V5) letter2
08/22/2026M01211053-S1Open ↗
Showing 1 of 2 on file for this type
▸BISHOUSE CONNECTION SIGNOFF1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSUPERSEDING LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership129
▸BISCOST AFFIDAVIT125
11/29/2023100293424Open ↗
01/08/2021140712708Open ↗
03/06/2020123885876Open ↗
Showing 3 of 125 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT4
04/26/2018123435586Open ↗
Showing 1 of 4 on file for this type
▸Filing & Intake Forms129
▸BISEFILING COVER SHEET67
03/06/2020123885876Open ↗
10/25/2019123748089Open ↗
12/17/2018123510931Open ↗
Showing 3 of 67 on file for this type
▸BISADDITIONAL INFORMATION41
04/23/2019123510931Open ↗
07/20/2018123501111Open ↗
05/02/2018140712708Open ↗
Showing 3 of 41 on file for this type
▸BISBOROUGH INTAKE FORM12
09/28/2023100293424Open ↗
02/20/2020123510931Open ↗
02/20/2020123510931Open ↗
Showing 3 of 12 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET9
11/10/2017140715171Open ↗
11/06/2017140712708Open ↗
10/30/2017140709990Open ↗
Showing 3 of 9 on file for this type
▸Other Documents21
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION16
03/06/2020123885876Open ↗
Showing 1 of 16 on file for this type
▸BISSupporting Document: Fee Exempt2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSEPTIC - SUPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISTEMPORARY FLOOD SHIELDS: EMERGENCY FLOOD PLAN1
04/18/2018123435586Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type