← Back
Office, 20+ stories, with or without commercial
150 Broadway
150 BROADWAY · BIN 1001087
💬 Discuss this project
1924Year Built
23Stories
O4Building Class
C5-5Zoning
279,669 sfGross Floor Area
92Units
LL97 Covered4 Open Violations ▸FISP: SAFEFDNY Report ↗
Office, 20+ stories, with or without commercial · Owner of record: 150 BROADWAY N.Y. ASSOCIATES, L.P. · 13,133 sf lot · 21.3 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Roof7p · 7 filings · 20 docs
Bulkhead2p · 2 filings · 12 docs
Floor 223p · 3 filings · 9 docs
Floor 211p · 1 filing · 5 docs
Floor 20
Floor 19
Floor 18
Floor 176p · 4 filings · 17 docs
Floor 161p · 1 filing · 5 docs
Floor 153p · 2 filings · 14 docs
Floor 143p · 2 filings · 12 docs
Floor 131p · 1 filing · 5 docs
Floor 126p · 4 filings · 20 docs
Floor 111p · 1 filing · 5 docs
Floor 101p · 1 filing · 5 docs
Floor 91p · 1 filing · 5 docs
Floor 8
Floor 71p · 1 filing · 5 docs
Floor 611p · 3 filings · 15 docs
Floor 52p · 2 filings · 9 docs
Floor 41p · 1 filing · 5 docs
Floor 311p · 2 filings · 10 docs
Floor 22p · 2 filings · 20 docs
Floor 116p · 9 filings · 20 docs
Cellar11p · 6 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JEMB REALTY11609/13/2026
75 BROAD7607/08/2026
150 BROADWAY NY ASSOCIATES7503/22/2026
150 BROADWAY ASSOCIATES1803/22/2026
JC CONTRACTING MGMT203/22/2026
PRATT CONSTRUCTION AND RE103/22/2026
AAK ACQUISITIONS103/22/2026
BANK OF AMERICA103/22/2026
BAILY NY ASSOCIATES203/22/2026
N.Y ASSOCIATES L.P203/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RIZZO GROUP1903/21/2026
PEROTTO CONSULTING MANAGEMENT603/21/2026
LOUIS STRIAR203/21/2026
JAM CONSULTANTS, INC.1203/21/2026
JUST ARCHITECTURE603/21/2026
A1 EXPEDITING SERVICE CORP.403/21/2026
PRAT ENTERPRISES203/21/2026
SUPPORT BUILDINGS OF NEW YORK103/21/2026
AE DESIGN SOLUTION403/21/2026
RIGHT WAY SERVICES NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BREND RESTORATION LLCGeneral Contractor1407/08/2026
INTERSYSTEM INSTALLATIONGeneral Contractor1407/08/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor1107/08/2026
BROADWAY PRIME CONSTRUCTIGeneral Contractor1007/08/2026
JC CONTRACTING.MGMT LLCGeneral Contractor904/09/2026
VALENTINE CONST MGMT LLCGeneral Contractor807/08/2026
PRIME CONSTRUCTION MGMTGeneral Contractor507/08/2026
PSI PARTNERS, LLCFire Protection507/08/2026
BALATON CONSULTING LLCScaffold407/08/2026
NUCOR CONSTRUCTION CORPGeneral Contractor404/09/2026
CLUNE CONSTRUCTION CO LPGeneral Contractor404/09/2026
PRAT ENTERPRISES CORPGeneral Contractor303/21/2026
4TL CONSTRUCTION LLCGeneral Contractor307/08/2026
ACCURATE MECHANICAL INCPlumbing207/08/2026
ACCURATE MECHANICAL INCFire Protection207/08/2026
EMCOR SERVICES NY/NJ INCGeneral Contractor207/08/2026
SCHIMENTI CONSTRUCTION COGeneral Contractor203/21/2026
MEGA PLBG CORPFire Protection107/08/2026
TREVOR DUNWELLElectrical103/21/2026
ANT YAPI NEW YORK LLCGeneral Contractor107/08/2026
PUGLIESE FRANKElectrical103/21/2026
NYC IRONWORKERS LOCAL 40Electrical103/21/2026
MOLLER, GEORGEElectrical103/21/2026
A1 SPECIALIZED, INCScaffold107/08/2026
MICHAELOFF, STEVENElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MILROSE CONSULTANTS LLC2003405/19/2026
OBAID MIAN849202/20/2026
TROLYDIA TESTING & INSPEC4422408/07/2025
CONSULTING ENGINEER5093407/15/2025
LEO Y LEE ASSOCIATES2481212/10/2024
TRIANGLE INSPECTION & TES7495308/06/2024
SAG ENGINEERING & CONSULT6081807/12/2024
OUTSOURCE SPECIAL INSPECT2827406/30/2022
AK ENGINEERING PC678311/19/2021
Building Lifecycle
All (300)Filed (57)Permit Issued (62)Signed Off (42)Facade (FISP) (15)Violation (60)Inspection (18)Objection (16)Special Inspection (30)
08/06/2026
Signed off — Alteration
Modification to existing Sprinkler system as per plans filed herewith. No change in use, egress or occupancy under this application.
M01296679-I1
07/30/2026
Filed — Alteration
THIS APPLICATION IS BEING FILED TO CORRECT ADDRESS INFORMATION FOR INSTALLED EXHAUST SYSTEM. ALL PHYSICAL WORK HAS BEEN FILED APPROVED & SIGNED OFF UNDER APPLICATION #M01245630.
M01428755-I1
07/30/2026
Signed off — Alteration
M01296276-I1
07/24/2026
Signed off — Alteration
Exterior restoration to include brick replacement, terra cotta repairs, sill replacement and metal coping repairs as per plans filed herewith. No change to use, egress or occupancy.
M00949477-I1
07/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
07/17/2026
Special inspection requirement — Sprinkler Systems
Christopher Drutjons
07/09/2026
Objection resolved — Resolved
07/09/2026
Objection resolved — Resolved
07/09/2026
Special inspection requirement — Final
07/09/2026
Special inspection requirement — Mechanical Systems
06/09/2026
Signed off — Alteration
Air conditioning units replacement on the roof. All existing ductwork to remain. No change in use egress and occupancy.
M01296852-I1
06/08/2026
Signed off — Alteration
NON-ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - BOOBLIQ BAGEL BISTRO. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01333817-I1
05/29/2026
Objection raised — Scope
05/29/2026
Objection raised — Cost
05/26/2026
Permit issued — Sign
M01333817-I1-SG
05/19/2026
Filed — Alteration
Modification to existing Sprinkler system as per plans filed herewith. No change in use, egress or occupancy under this application.
M01296679-P1
05/11/2026
Signed off — Alteration
Replacement of (3) rooftop air conditioning units on the lower setback roof. All existing ductwork to remain. No change in use egress and occupancy.
M01355026-I1
05/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
05/11/2026
Special inspection requirement — Sprinkler Systems
Christopher Drutjons
05/01/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300 PSF
M00656053-I1
04/28/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
04/28/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/28/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/23/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/16/2026
Signed off — Alteration
M01171226-I1
04/16/2026
Signed off — Alteration
Plumbing work only to install new plumbing fixtures at future eating and drinking establishment at first floor only
M01245627-I1
04/16/2026
Signed off — Alteration
Sprinkler work to modify existing system for future eating and drinking establishment at first floor only.
M01245632-I1
04/16/2026
Signed off — Alteration
Mechanical work to furnish and install HVAC equipement and systems for future eating and drinking establishment at first floor and low roof
M01245630-I1
03/26/2026
Permit issued — Mechanical Systems
M01355026-I1-MS
03/23/2026
Violation issued (FDNY_NOV, closed)
03/23/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/13/2026
Signed off — Alteration
Modification to existing plumbing fixtures as per plans filed herewith. No change in use, egress or occupancy under this application.
M01296675-I1
02/24/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/23/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/20/2026
Filed — Alteration
Replacement of (3) rooftop air conditioning units on the lower setback roof. All existing ductwork to remain. No change in use egress and occupancy.
M01355026-I1
02/20/2026
Violation issued (FDNY_ORDER, closed)
02/20/2026
Violation issued (FDNY_NOV, closed)
02/20/2026
Violation issued (FDNY_ORDER, closed)
02/19/2026
Signed off — Alteration
M01296664-I1
02/19/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/11/2026
Objection resolved — Addressed
02/10/2026
Objection raised — Admin
02/04/2026
Permit issued — Mechanical Systems
M01296852-I1-MS
02/03/2026
Objection resolved — Addressed
02/03/2026
Special inspection requirement — Maintenance information
Obaid Mian
02/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Obaid Mian
02/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
Obaid Mian
02/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
Obaid Mian
02/03/2026
Special inspection requirement — Mechanical Systems
Obaid Mian
02/03/2026
Special inspection requirement — Final
Obaid Mian
01/30/2026
Objection raised — Fire_Protection
01/28/2026
Cycle 9 facade report submitted
01/26/2026
Cycle 9 facade report signed — SAFE
01/21/2026
Filed — Alteration
NON-ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - BOOBLIQ BAGEL BISTRO. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01333817-I1
01/20/2026
Special inspection requirement — Final
ADITYA DESAI
01/19/2026
Filed — Alteration
Air conditioning units replacement on the roof. All existing ductwork to remain. No change in use egress and occupancy.
M01296852-I1
01/08/2026
Cycle 9 facade inspection completed
01/06/2026
Violation issued (FDNY_ORDER, closed)
01/06/2026
Violation issued (FDNY_ORDER, closed)
01/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
Latest 60 of 300 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignSigned-offMAD SIGNS INC05/26/2026
DOB NOWMechanical SystemsSigned-offEMCOR SERVICES NY/NJ INC03/26/2026
DOB NOWMechanical SystemsSigned-offM & S MECHANICAL SERVICES02/04/2026
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC12/23/2025
DOB NOWMechanical SystemsSigned-offKOSTYANTYN GARKUSHA11/25/2025
DOB NOWSprinklersSigned-offMORA FIRE PROTECTION LLC11/19/2025
DOB NOWPlumbingSigned-offA&A PLUMBING CORP11/17/2025
DOB NOWGeneral ConstructionSigned-offCLUNE CONSTRUCTION CO LP11/14/2025
DOB NOWMechanical SystemsSigned-offCLUNE CONSTRUCTION CO LP11/12/2025
DOB NOWStructuralSigned-offJC CONTRACTING.MGMT LLC11/05/2025
DOB NOWSuspended ScaffoldPermit IssuedJC CONTRACTING MGMT LLC11/03/2025
DOB NOWSuspended ScaffoldPermit IssuedJC CONTRACTING MGMT LLC10/01/2025
DOB NOWPlumbingSigned-offMEGA PLBG CORP09/11/2025
DOB NOWSprinklersSigned-offREAL PLUMBING CORP09/11/2025
DOB NOWGeneral ConstructionPermit IssuedNUCOR CONSTRUCTION CORP08/11/2025
DOB NOWGeneral ConstructionPermit IssuedNUCOR CONSTRUCTION CORP08/11/2025
DOB NOWGeneral ConstructionPermit IssuedNUCOR CONSTRUCTION CORP08/11/2025
DOB NOWGeneral ConstructionPermit IssuedNUCOR CONSTRUCTION CORP08/11/2025
DOB NOWStructuralSigned-offJC CONTRACTING.MGMT LLC08/06/2025
DOB NOWGeneral ConstructionSigned-offANT YAPI NEW YORK06/17/2025
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC04/17/2025
DOB NOWGeneral ConstructionSigned-offJC CONTRACTING.MGMT LLC03/21/2025
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC12/31/2024
DOB NOWSuspended ScaffoldPermit IssuedPRATT CONSTRUCTION & RES10/11/2024
DOB NOWSuspended ScaffoldPermit IssuedJC CONTRACTING MGMT LLC09/30/2024
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC04/22/2024
DOB NOWSuspended ScaffoldPermit IssuedJC CONTRACTING MGMT LLC03/27/2024
DOB NOWStructuralSigned-offJC CONTRACTING.MGMT LLC03/22/2024
DOB NOWStructuralSigned-offJC CONTRACTING.MGMT LLC02/22/2024
DOB NOWMechanical SystemsSigned-offVALENTINE CONST MGMT LLC02/16/2024
DOB NOWStructuralSigned-offVALENTINE CONST MGMT LLC02/14/2024
DOB NOWGeneral ConstructionSigned-offVALENTINE CONST MGMT LLC02/08/2024
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC01/02/2024
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC01/03/2023
DOB NOWSprinklersSigned-offMORA FIRE PROTECTION LLC06/02/2022
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC01/05/2022
DOB NOWSprinklersSigned-offMORA FIRE PROTECTION LLC12/22/2021
DOB NOWMechanical SystemsSigned-offVALENTINE CONST MGMT LLC11/10/2021
DOB NOWSignSigned-offNORTH SHORE NEON SIGN CO09/24/2021
DOB NOWSignSigned-offNORTH SHORE NEON SIGN CO09/24/2021
+ 60 more permits on file
2 projects · most recent 07/30/2026
Heating and Air Conditioning Systems Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2026——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NAM2 60,000 BTU · Heat Pump Outdoor ×1
01/19/2026Signed-offM & S MECHANICAL SERVICESAir Conditioning Systems
Cooling
York AV18C0BP2L1ADE14A1 210,000 BTU · Ahu ×3
Daikin DZ14SA0483AB 48,000 BTU · Condensing Unit ×2
2 projects · most recent 05/19/2026
FiledStatusContractorScope
05/19/2026Signed-offPSI PARTNERS, LLC58 heads
12/23/2020Permit IssuedSEAN COAKLEY P & H INC—
2 projects · most recent 05/19/2026
Water/Sanitary
FiledStatusContractorScope
05/19/2026———
12/23/2020Signed-offSEAN COAKLEY P & H INCWater/Sanitary
17 projects · most recent 11/21/2025
General Wiring Lighting
FiledStatusContractorScope
11/21/2025CompleteA.L. ELECTRICAL CORP.General Wiring
11/17/2025CompleteEPIC ELECTRIC INCGeneral Wiring
03/13/2024CompleteELPO ELECTRICAL CONTG INCGeneral Wiring
05/16/2023Permit IssuedBOROWIDE ELECT'L CONTR'S—
02/14/2022Permit IssuedELPO ELECTRICAL CONTG INCGeneral Wiring
01/05/2022CompleteBOROWIDE ELECT'L CONTR'S—
11/01/2021CompleteBIG ANT ELECTRIC, INCGeneral Wiring, Lighting
09/20/2021CompleteAMR ELEC'L CONTRG CORPGeneral Wiring
04/21/2021Permit IssuedSNJ ELECTL CONTRG LLC—
01/11/2020CompleteSTEVEN FARKAS—
01/07/2020CompleteELPO ELECTRICAL CONTG INCGeneral Wiring
12/04/2019CompleteELPO ELECTRICAL CONTG INCGeneral Wiring
11/12/2019CompleteELPO ELECTRICAL CONTG INCGeneral Wiring
03/27/2019CompleteTUXEDO ELEC'L CONTR'G INCGeneral Wiring
02/20/2019CompleteT. DIRUSSO ELEC'L CONT IN—
1 project · most recent 04/10/2018
Scaffold
FiledStatusContractorScope
04/10/2018Permit IssuedBREND RESTORATION LLCScaffold
2 projects · most recent 12/11/2025
Suspended Scaffold (SC)
FiledStatusContractorScope
12/11/2025———
12/10/2024Permit IssuedJC CONTRACTING MGMT LLCSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 18
DateTypeResultReport
04/28/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
04/28/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/28/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/23/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/23/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/24/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/23/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/19/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/31/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/24/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/05/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/20/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/08/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/07/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/13/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/13/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/07/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 124
DateRequirementInspectorRole
07/17/2026Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
07/17/2026Sprinkler SystemsChristopher Drutjonsspecial
07/09/2026Mechanical Systems—special
07/09/2026Final—progress
05/11/2026Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
05/11/2026Sprinkler SystemsChristopher Drutjonsspecial
02/03/2026Mechanical SystemsObaid Mianspecial
02/03/2026HVAC-R and service water piping design and insulationObaid Mianenergy_progress
02/03/2026HVAC-R and service water heating equipmentObaid Mianenergy_progress
02/03/2026HVAC-R and service water heating system controlsObaid Mianenergy_progress
02/03/2026FinalObaid Mianprogress
02/03/2026Maintenance informationObaid Mianenergy_progress
01/20/2026FinalADITYA DESAIprogress
10/30/2025Final—progress
10/30/2025Energy Code Compliance Inspections—progress
10/30/2025Sprayed fire-resistant materials—special
10/30/2025Fire-Resistant Penetrations and Joints—special
10/02/2025Mechanical SystemsObaid Mianspecial
10/02/2025Mechanical SystemsChristopher Drutjonsspecial
10/02/2025FinalChristopher Drutjonsprogress
10/02/2025Ventilation and air distribution systemChristopher Drutjonsenergy_progress
10/02/2025Duct leakage testing, insulation and designChristopher Drutjonsenergy_progress
10/02/2025Maintenance informationObaid Mianenergy_progress
10/02/2025HVAC-R and service water heating equipmentObaid Mianenergy_progress
10/02/2025HVAC-R and service water heating system controlsObaid Mianenergy_progress
Latest 25 of 124.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Boobliq Bagel BistroRestaurant / Food Service—
Project M01333817 Alteration · LOC Issued · 01/21/2026
United Vein and Vascular CentersMedical / HealthcareFloor 12
Project M01296276 Alteration · LOC Issued · 10/24/2025
Project M01296664 Alteration · LOC Issued · 10/23/2025
Project M01296675 Alteration · LOC Issued · 10/23/2025
Project M01296679 Alteration · LOC Issued · 10/23/2025
LifeStance HealthMedical / HealthcareFloor 5
Project M00569591 Alteration · LOC Issued · 09/16/2021
Schwartz LevineOfficeFloor 17
Project M00254669 Alteration · LOC Issued · 12/10/2019
Project M00254701 Alteration · LOC Issued · 12/10/2019
Project M00254731 Alteration · LOC Issued · 12/10/2019
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 1,093 on file (BIS + DOB NOW)
▸Plans & Drawings68
▸DOB NOWPlans/Sketch49
09/06/2026M00016769-I1Request digital key ↗
09/06/2026M00032841-I1Request digital key ↗
09/06/2026M00071119-I1Request digital key ↗
Showing 3 of 49 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler7
09/05/2026M00247989-I1Request digital key ↗
09/05/2026M00254731-I1Request digital key ↗
09/05/2026M00311320-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems4
09/05/2026M00247904-I1Request digital key ↗
09/05/2026M00254669-I1Request digital key ↗
09/04/2026M00408498-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Plumbing3
09/05/2026M00247945-I1Request digital key ↗
09/05/2026M00254701-I1Request digital key ↗
09/04/2026M00428178-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold2
09/06/2026M00071980-I1Request digital key ↗
Showing 1 of 2 on file for this type
▸DOB NOWPlans/Sketch - General Construction2
09/04/2026M00447170-I1Request digital key ↗
09/04/2026M00450715-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
09/04/2026M00447363-I1Request digital key ↗
▸Applications & Permits142
▸BISPLAN / WORK APPROVAL APPLICATION86
02/09/2026123077053Open ↗
07/17/2025123077053Open ↗
10/18/2022140987332Open ↗
Showing 3 of 86 on file for this type
▸BISWORK PERMIT APPLICATION50
03/01/2021140993021Open ↗
01/07/2021140994592Open ↗
01/07/2021140994583Open ↗
Showing 3 of 50 on file for this type
▸BISPLACE OF ASSEMBLY4
06/13/2024122269179Open ↗
06/11/2024122269179Open ↗
Showing 2 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Seals & Professional Certifications331
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION99
04/17/2020123743761Open ↗
04/17/2020123743761Open ↗
04/17/2020123743761Open ↗
Showing 3 of 99 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature65
09/06/2026M00016769-I1Open ↗
09/06/2026M00032841-I1Open ↗
09/05/2026M00247904-I1Open ↗
Showing 3 of 65 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature57
09/29/2026M00428178-I1Open ↗
09/29/2026M00428178-I1Open ↗
09/23/2026M01245632-I1Open ↗
Showing 3 of 57 on file for this type
▸DOB NOWProgress Inspector Seal & Signature47
09/28/2026M00569591-I1Open ↗
09/28/2026M00569591-I1Open ↗
09/23/2026M01296852-I1Open ↗
Showing 3 of 47 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT24
02/09/2021140998428Open ↗
12/23/2020140994592Open ↗
12/23/2020140994583Open ↗
Showing 3 of 24 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST21
11/19/2019123743761Open ↗
11/13/2019123739892Open ↗
Showing 2 of 21 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY6
02/09/2021140998428Open ↗
12/23/2020140994592Open ↗
12/23/2020140994583Open ↗
Showing 3 of 6 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION6
02/09/2021140998428Open ↗
12/23/2020140994592Open ↗
12/23/2020140994583Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸Trade Schedules & Equipment60
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE20
05/17/2019123893741Open ↗
Showing 1 of 20 on file for this type
▸BISSELF-CERT PLUMBING NOTICE12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISEQUIPMENT USE PERMITS10
02/07/2022123077053Open ↗
Showing 1 of 10 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISFIRE PROTECTION PLAN(FPP): FDNY APPROVAL2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSTANDPIPE INSP REPORT : FP-841
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSPRINKLER INSP REPORT : FP-851
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTENANT PROTECTION PLAN AND NOTES1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos95
▸DOB NOWDEP ACP-5: Asbestos Assessment Report47
09/05/2026M00247904-I1Open ↗
09/05/2026M00254669-I1Open ↗
09/04/2026M00428178-I1Open ↗
Showing 3 of 47 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)35
12/23/2020140994592Open ↗
12/23/2020140994583Open ↗
11/19/2019123743761Open ↗
Showing 3 of 35 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
09/04/2026M00408516-I1Open ↗
Showing 1 of 2 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISASBESTOS: VARIANCE (DEP FORM V5)1
12/28/2020140987332Open ↗
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance77
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS38
04/17/2020123743761Open ↗
04/13/2020123739892Open ↗
11/19/2019123743761Open ↗
Showing 3 of 38 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS17
10/19/2022140987332Open ↗
10/18/2022140987332Open ↗
06/23/2022140993021Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY11
10/19/2022140987332Open ↗
10/18/2022140987332Open ↗
10/27/2021123077053Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS4
12/23/2020140994592Open ↗
12/23/2020140994583Open ↗
12/21/2020140993021Open ↗
Showing 3 of 4 on file for this type
▸BISENERGY CODE COMPLIANCE INSPECTIONS2
09/16/2021140994592Open ↗
09/15/2021140994583Open ↗
▸BISTECHNICAL REPORT: ENERGY2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.2
09/03/2026M00569536-I1Open ↗
Showing 1 of 2 on file for this type
▸DOB NOWPreliminary Commissioning Report Certification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports32
▸BISTECHNICAL REPORT: RESPONSIBILITY19
10/19/2022140987332Open ↗
10/18/2022140987332Open ↗
10/18/2022140987332Open ↗
Showing 3 of 19 on file for this type
▸BISHYDRAULIC FLOW CALCULATIONS6
05/31/2019123396173Open ↗
05/31/2019123396173Open ↗
05/31/2019123396173Open ↗
Showing 3 of 6 on file for this type
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)2
09/16/2021140994592Open ↗
09/15/2021140994583Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
09/15/2021140994583Open ↗
▸Approvals, Objections & Sign-offs93
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST63
10/19/2022140987332Open ↗
06/24/2022140993021Open ↗
01/20/2022122979492Open ↗
Showing 3 of 63 on file for this type
▸BISADMINISTRATIVE OBJECTIONS10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE7
02/09/2026123077053Open ↗
07/17/2025123077053Open ↗
10/26/2021123077053Open ↗
Showing 3 of 7 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION6
12/04/2019123354850Open ↗
05/31/2019123396173Open ↗
Showing 2 of 6 on file for this type
▸BISFINAL2
09/16/2021140994592Open ↗
09/15/2021140994583Open ↗
▸BISSUPERSEDING LETTER2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWDEP Variance (V5) letter2
09/04/2026M00408516-I1Open ↗
Showing 1 of 2 on file for this type
▸BISCCD1-Construction Code Determination1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership93
▸BISCOST AFFIDAVIT88
10/19/2022140987332Open ↗
10/18/2022140987332Open ↗
10/18/2022140987332Open ↗
Showing 3 of 88 on file for this type
▸BISOK TO ISSUE TCO PENDING RESOLUTION OFOPEN FACADE VIOLATION - AFFIDAVIT ATTACHED3
02/17/2026123077053Open ↗
01/29/2025123077053Open ↗
10/28/2024123077053Open ↗
▸BISOK TO ISSUE TCO PENDING RESOLUTION OFOPEN FACADE VIOLATIONS - AFFIDAVIT ATTACHED1
01/24/2024123077053Open ↗
▸BISLL58-88 CIVIL PENALTY AFFIDAVIT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Filing & Intake Forms79
▸BISEFILING COVER SHEET41
11/19/2019123743761Open ↗
11/13/2019123739892Open ↗
05/17/2019123893741Open ↗
Showing 3 of 41 on file for this type
▸BISBOROUGH INTAKE FORM19
05/11/2020101915420Open ↗
05/11/2020103609908Open ↗
04/17/2020123743761Open ↗
Showing 3 of 19 on file for this type
▸BISADDITIONAL INFORMATION12
11/18/2021123077053Open ↗
02/25/2021140987332Open ↗
02/18/2021140993021Open ↗
Showing 3 of 12 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET7
02/09/2021140998428Open ↗
12/23/2020140994592Open ↗
12/23/2020140994583Open ↗
Showing 3 of 7 on file for this type
▸Other Documents18
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸DOB NOWCalculations3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWManufacturer's Specifications3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPLOT DIAGRAM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWPro Cert Restriction Exception (LL158/17)2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSupporting Document: Fee Exempt1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWIRA Certification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type